Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Polysomnography (PSG) is the “gold standard” for monitoring sleep. Alternatives to PSG are of interest for clinical, research, and personal use. Wrist-worn actigraph devices have been utilized in research settings for measures of sleep for over two decades. Whether sleep measures from commercially available devices are similarly valid is unknown. We sought to determine the validity of five wearable devices: Basis Health Tracker, Misfit Shine, Fitbit Flex, Withings Pulse O2, and a research-based actigraph, Actiwatch Spectrum. We used Wilcoxon Signed Rank tests to assess differences between devices relative to PSG and correlational analysis to assess the strength of the relationship. Data loss was greatest for Fitbit and Misfit. For all devices, we found no difference and strong correlation of total sleep time with PSG. Sleep efficiency differed from PSG for Withings, Misfit, Fitbit, and Basis, while Actiwatch mean values did not differ from that of PSG. Only mean values of sleep efficiency (time asleep/time in bed) from Actiwatch correlated with PSG, yet this correlation was weak. Light sleep time differed from PSG (nREM1 + nREM2) for all devices. Measures of Deep sleep time did not differ from PSG (SWS + REM) for Basis. These results reveal the current strengths and limitations in sleep estimates produced by personal health monitoring devices and point to a need for future development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Several studies have reported similar findings for the Fitbit Flex™ device (Montgomery-Downs et al., 2012; Mantua et al., 2016; Kang et al., 2017).”
From A Critical Review of Consumer Wearables, Mobile Applications, and Equipment for Providing Biofeedback, Monitoring Stress, and Sleep in Physically Active Populations (2018) · cites this paper as Mantua et al., 2016
In the citing paper
“sleep assessment algorithms are frequently proprietary and validated in small populations, making their measurement validity unclear5–8”
From Self-supervised learning of accelerometer data provides new insights for sleep and its association with mortality (2024) · cites this paper as [5]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · Cited by 6,530
Ohayon, M. M., Carskadon, M. A., Guilleminault, C., & Vitiello, M. V. (2004) · Sleep · doi:10.1093/sleep/27.7.1255 · Cited by 3,349
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415 · cited 2×
“it relies on hand-scored data using participant diaries of events (bedtime/wake time and time in bed; [8,9]).”
BackgroundMethodSystematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Marino, M., Li, Y., Rueschman, M. N., Winkelman, J. W., Ellenbogen, J. M., Solet, J. M., Dulin, H., Berkman, L. F., & Buxton, O. M. (2013) · Sleep · doi:10.5665/sleep.3142 · Cited by 1,056 · cited 1×
“The high reliability of the Actiwatch Spectrum for estimating TST is consistent with other studies [12].”
ResultWearable Devices as Facilitators, Not Drivers, of Health Behavior Change
Patel, M. S., Asch, D. A., & Volpp, K. G. (2015) · JAMA · doi:10.1001/jama.2014.14781 · Cited by 808 · cited 1×
“These commercially available products have begun to overcome limitations in cost (as low as $60) and usability, and have been validated several times in the area of physical activity [3–6].”
BackgroundFerguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · cited 1×
“These commercially available products have begun to overcome limitations in cost (as low as $60) and usability, and have been validated several times in the area of physical activity [3–6].”
BackgroundReliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360 · cited 1×
“These commercially available products have begun to overcome limitations in cost (as low as $60) and usability, and have been validated several times in the area of physical activity [3–6].”
BackgroundExploring Goal-setting, Rewards, Self-monitoring, and Sharing to Motivate Physical Activity
Munson, S., & Consolvo, S. (2012) · Proceedings of the 6th International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2012.248691 · Cited by 355 · cited 1×
“Personal health monitoring devices have rapidly gained popularity in the general public, providing the potential to improve feedback and motivation [1,2] towards improvements in physical activity, dietary intake, and sleep.”
Background
Cited by
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Henriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
“Mio, Misfit, Polar, Withings, and Xiaomi, were the only brands that automatically synchronized fitness data to both of these repositories through these open APIs.”
MethodInfluentialPeake, J. M., Kerr, G., & Sullivan, J. P. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00743 · Cited by 523
“Several studies have reported similar findings for the Fitbit Flex device (Montgomery-Downs et al., 2012; Mantua et al., 2016; Kang et al., 2017).”
ResultAccuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Journal of Medical Internet Research · doi:10.2196/16273 · Cited by 446
“%) relied on PSG as reference to evaluate Fitbit performance [22,25-28, 30, 31, 37-42 37-42 ] ; the other 9 ( 41”
Performance of seven consumer sleep-tracking devices compared with polysomnography
Chinoy, E. D., Cuellar, J. A., Huwa, K. E., Jameson, J. T., Watson, C. H., Bessman, S. C., Hirsch, D. A., Cooper, A. D., Drummond, S. P. A., & Markwald, R. R. (2021) · Sleep · doi:10.1093/sleep/zsaa291 · Cited by 433
“Similar to many other recent studies that evaluated device sleep stage-tracking performance [26–29, 35–37, 45], we found that for both sleep summary metrics as well as EBE agreement that the consumer devices demonstrated mixed and often poor results for detection of sleep stages versus PSG.”
A validation study of Fitbit Charge 2™ compared with polysomnography in adults
de Zambotti, M., Goldstone, A., Claudatos, S., Colrain, I. M., & Baker, F. C. (2018) · Chronobiology International · doi:10.1080/07420528.2017.1413578 · Cited by 413
“Similar performance (based on PSG-device discrepancies only) between standard actigraphy and wearables is also suggested by Mantua et al. (2016) who compared four different sleep-trackers (Basic Health Tracker 2014 Ed., Fitbit Flex™, Misfit Shine™, Withings Pulse O2) worn on the wrist, and…”
BackgroundInfluentialWearable sensors for monitoring the internal and external workload of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0149-2 · Cited by 330
The Sleep of the Ring: Comparison of the ŌURA Sleep Tracker Against Polysomnography
de Zambotti, M., Rosas, L., Colrain, I. M., & Baker, F. C. (2019) · Behavioral Sleep Medicine · doi:10.1080/15402002.2017.1300587 · Cited by 287
“Other devices have classified “deep” sleep as a combination of N3 and REM, which they have tended to overestimate, or had varying results depending on the amount of deep sleep (Mantua et al., 2016).”
BackgroundSensors and Functionalities of Non-Invasive Wrist-Wearable Devices: A Review
Kamišalić, A., Fister, I., Turkanović, M., & Karakatič, S. (2018) · Sensors · doi:10.3390/s18061714 · Cited by 272
“Wrist-based actigraph devices have been utilized in research settings for monitoring sleep quality [84].”
MethodDepner, C. M., Cheng, P. C., Devine, J. K., Khosla, S., de Zambotti, M., Robillard, R., Vakulin, A., & Drummond, S. P. A. (2020) · Sleep · doi:10.1093/sleep/zsz254 · Cited by 245
How consumer physical activity monitors could transform human physiology research
Wright, S. P., Hall Brown, T. S., Collier, S. R., & Sandberg, K. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00349.2016 · Cited by 234
Wu, M., Chen, J., Ma, Y., Yan, B., Pan, M., Peng, Q., Wang, W., Han, L., Liu, J., & Zeng, H. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta09735g · Cited by 195
Military applications of soldier physiological monitoring
Friedl, K. E. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2018.06.004 · Cited by 194
Baron, K. G., Duffecy, J., Berendsen, M. A., Cheung Mason, I., Lattie, E. G., & Manalo, N. C. (2018) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.12.002 · Cited by 186
“The majority of studies compared the wearable or mobile sleep tracking technology agains t PSG or EEG (n=14)[14-26] or actigraphy (n=4) [21, 23, 27-29].”
Conley, S., Knies, A., Batten, J., Ash, G., Miner, B., Hwang, Y., Jeon, S., & Redeker, N. S. (2019) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2019.05.001 · Cited by 172
Clinical Applications of Mobile Health Wearable–Based Sleep Monitoring: Systematic Review
Guillodo, E., Lemey, C., Simonnet, M., Walter, M., Baca-García, E., Masetti, V., Moga, S., Larsen, M., HUGOPSY Network, Ropars, J., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/10733 · Cited by 167
Berryhill, S., Morton, C. J., Dean, A., Berryhill, A., Provencio-Dean, N., Patel, S. I., Estep, L., Combs, D., Mashaqi, S., Gerald, L. B., et al. (2020) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8356 · Cited by 164
Mehrabadi, M. A., Azimi, I., Sarhaddi, F., Axelin, A., Niela‐Vilén, H., Myllyntausta, S., Stenholm, S., Dutt, N. D., Liljeberg, P., & Rahmani, A. M. (2020) · JMIR mhealth and uhealth · doi:10.2196/20465 · Cited by 205
Bagot, K. S., Matthews, S. A., Mason, M., Squeglia, L. M., Fowler, J., Gray, K., Herting, M., May, A., Colrain, I., Godino, J., et al. (2018) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2018.03.008 · Cited by 145
“…affecting intelligence (Edwards et al., 2010; Perera et al., 2012), mood, anxiety and behavioral dysregulation disorders (Perera et al., 2014; Liu et al., 2013; Margolis et al., 2016), cognition (Chiu et al., 2013; Sunyer et al., 2015), and brain structure measured by MRI (Peterson et al., 2015).”
BackgroundKang, S.-G., Kang, J. M., Ko, K.-P., Park, S.-C., Mariani, S., & Weng, J. (2017) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2017.03.009 · Cited by 146
Wearable sensors for activity monitoring and motion control: A review
Wang, X., Yu, H., Kold, S., Rahbek, O., & Bai, S. (2023) · Biomimetic Intelligence and Robotics · doi:10.1016/j.birob.2023.100089 · Cited by 213
Chikersal, P., Doryab, A., Tumminia, M. J., Villalba, D. K., Dutcher, J. M., Liu, X., Cohen, S., Creswell, K. G., Mankoff, J. C., Creswell, J. D., et al. (2021) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3422821 · Cited by 216
Mendelsohn, D., Despot, I., Gooderham, P. A., Singhal, A., Redekop, G. J., & Toyota, B. D. (2019) · Medical Education · doi:10.1111/medu.13757 · Cited by 124
Lehrer, H. M., Yao, Z., Krafty, R. T., Evans, M. A., Buysse, D. J., Kravitz, H. M., Matthews, K. A., Gold, E. B., Harlow, S. D., Samuelsson, L. B., et al. (2022) · SLEEP Advances · doi:10.1093/sleepadvances/zpac001 · Cited by 153
“Although the mean SE difference between actigraphy and PSG in our study was small, variability between measures increased as SE decreased, consistent with prior studies [46, 49, 54].”
ResultMoreno-Pino, F., Porras-Segovia, A., López-Esteban, P., Artés, A., & Baca-García, E. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8032 · Cited by 112
Lee, T., Cho, Y., Cha, K. S., Jung, J., Cho, J., Kim, H., Kim, D., Hong, J., Lee, D., Keum, M., et al. (2023) · JMIR mhealth and uhealth · doi:10.2196/50983 · Cited by 147
Liang, Z., & Martell, M. A. C. (2018) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-018-0013-1 · Cited by 121
A Review of Approaches for Sleep Quality Analysis
Mendonca, F., Mostafa, S. S., Morgado-Dias, F., Ravelo-Garcia, A. G., & Penzel, T. (2019) · IEEE Access · doi:10.1109/access.2019.2900345 · Cited by 101
“[113], specifically, the Basis Health Tracker (Intel Corp, USA), the Fitbit Flex (Fitbit, USA), the Misfit Shine (MisfitWearables, USA), the Withings Pulse O2 (Withings, France) and the Actiwatch Spectrum (Philips Respironics, USA).”
BackgroundSvensson, T., Madhawa, K., Nt, H., Chung, U., & Svensson, A. K. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.01.020 · Cited by 139
Cook, J. D., Prairie, M. L., & Plante, D. T. (2017) · Journal of Affective Disorders · doi:10.1016/j.jad.2017.04.030 · Cited by 113
“Contrary to the results of these investigations, one study in healthy, young adults demonstrated comparable results in estimation of total sleep time for multiple fitness activity trackers, relative to PSG (Mantua et al., 2016).”
ResultWenzel, R., & Van Quaquebeke, N. (2018) · Organizational Research Methods · doi:10.1177/1094428117718627 · Cited by 98
“…high for normal step count and sleep duration; however, problems arise at slow walking speeds (under-estimation) and vigorous physical activity (overcounting) as well as for estimating sleep efficiency ( ¼ time in bed/time asleep) (Evenson, Goto, & Furberg, 2015; Mantua, Gravel, & Spencer, 2016).”
BackgroundSmart technologies toward sleep monitoring at home
Park, K. S., & Choi, S. H. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-0091-2 · Cited by 107
Klumpp, H., Roberts, J., Kapella, M. C., Kennedy, A. E., Kumar, A., & Phan, K. L. (2017) · Depression and Anxiety · doi:10.1002/da.22622 · Cited by 97
Sensors Capabilities, Performance, and Use of Consumer Sleep Technology
de Zambotti, M., Cellini, N., Menghini, L., Sarlo, M., & Baker, F. C. (2020) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2019.11.003 · Cited by 103
Bent, B., Wang, K., Grzesiak, E. A., Jiang, C., Qi, Y., Jiang, Y., Cho, P., Zingler, K., Ogbeide, F. I., Zhao, A., et al. (2020) · Journal of Clinical and Translational Science · doi:10.1017/cts.2020.511 · Cited by 103
“The Sleep and Circadian Rhythms module showcases an end-to-end solution that improves upon currently existing sleep detection algorithms [33,34].”
BackgroundPulmonary exposure to metal fume particulate matter cause sleep disturbances in shipyard welders
Chuang, H., Su, T.-Y., Chuang, K.-J., Hsiao, T.-C., Lin, H.-L., Hsu, Y.-T., Pan, C., Lee, K., Ho, S., & Lai, C. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2017.09.082 · Cited by 76
Smart Environments and Social Robots for Age-Friendly Integrated Care Services
Anghel, I. M., Cioara, T., Moldovan, D., Antal, C., Pop, C. D., Salomie, I., Pop, C. B., & Chifu, V. R. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17113801 · Cited by 90
“Most state-of-the-art approaches for monitoring sleep quality focus on comparative analyses and evaluation of the commercial devices available on the market [21,22,30], while only some of them present academic research solutions [20,23,31].”
BackgroundVarma, N., Cygankiewicz, I., Turakhia, M. P., Heidbuchel, H., Hu, Y.-F., Chen, L. Y., Couderc, J.-P., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009204 · Cited by 74
Sleep and Inflammatory Bowel Disease: An Important Bi-Directional Relationship
Qazi, T., & Farraye, F. A. (2018) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izy334 · Cited by 81
Kainec, K. A., Caccavaro, J., Barnes, M., Hoff, C., Berlin, A., & Spencer, R. M. C. (2024) · Sensors · doi:10.3390/s24020635 · Cited by 88
“Similar to previous studies, discerning light sleep from deep sleep was especially challenging for sleep-tracking devices [5,31,36,41,44–51].”
ResultSelf-citationApplication of health behaviour theory to sleep health improvement
Mead, M. P., & Irish, L. A. (2019) · Journal of Sleep Research · doi:10.1111/jsr.12950 · Cited by 84
“The TTM has been successful in modifying a number of different health behaviours, including diet, physical activity and exercise (Beresford et al., 1997; Marshall & Biddle, 2001).”
MethodThymi, M., Lobbezoo, F., Aarab, G., Ahlberg, J., Baba, K., Carra, M. C., Gallo, L. M., Laat, A. D., Manfredini, D., Lavigne, G. J., et al. (2021) · Journal of Oral Rehabilitation · doi:10.1111/joor.13170 · Cited by 76
Attenuation of short wavelengths alters sleep and the ip RGC pupil response
Ostrin, L. A., Abbott, K. S., & Queener, H. M. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12385 · Cited by 69
“60 Actigraphy has been shown to be a reliable and cost-effective method to obtain continuous measurements of sleep and activity.”
Use of wearable devices for post-discharge monitoring of ICU patients: a feasibility study
for the WEARable Information Technology for hospital INpatients (WEARIT-IN) study group, Kroll, R. R., McKenzie, E. D., Boyd, J. G., Sheth, P., Howes, D., Wood, M., & Maslove, D. M. (2017) · Journal of Intensive Care · doi:10.1186/s40560-017-0261-9 · Cited by 69
“Two recent studies have compared commercial-grade wearables with PSG in healthy subjects [10, 11].”
BackgroundDaily Associations Between Sleep and Physical Activity
Mead, M. P., Baron, K. G., Sorby, M., & Irish, L. A. (2019) · International Journal of Behavioral Medicine · doi:10.1007/s12529-019-09810-6 · Cited by 71
Tuominen, J., Peltola, K., Saaresranta, T., & Valli, K. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7682 · Cited by 75
Gruwez, A., Bruyneel, A.-V., & Bruyneel, M. (2019) · PLOS ONE · doi:10.1371/journal.pone.0210569 · Cited by 64
Ganster, D. C., Crain, T. L., & Brossoit, R. M. (2017) · Annual Review of Organizational Psychology and Organizational Behavior · doi:10.1146/annurev-orgpsych-032117-104613 · Cited by 69
A novel machine learning unsupervised algorithm for sleep/wake identification using actigraphy
Li, X., Zhang, Y., Jiang, F., & Zhao, H. (2020) · Chronobiology International · doi:10.1080/07420528.2020.1754848 · Cited by 71
Tossing and Turning in Bed: Nocturnal Movements in Parkinson's Disease
Mirelman, A., Hillel, I., Rochester, L., Din, S. D., Bloem, B. R., Avanzino, L., Nieuwboer, A., Maidan, I., Herman, T., Thaler, A., et al. (2020) · Movement Disorders · doi:10.1002/mds.28006 · Cited by 73
“Data from our wearable sensors cannot provide information on sleep stages or sleep disorders such as RBD, thus we opted not to discuss sleep but, rather, nocturnal rest to avoid confusion, although previous studies using actigraphy have shown high correlations between nocturnal movements and sleep stages as classi fi e…”
BackgroundDegroote, L., Hamerlinck, G., Poels, K., Maher, C., Crombez, G., De Bourdeaudhuij, I., Vandendriessche, A., Curtis, R. G., & DeSmet, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/16674 · Cited by 60
Ferguson, T., Curtis, R., Fraysse, F., Olds, T., Dumuid, D., Brown, W. J., Esterman, A., & Maher, C. A. (2023) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-023-01414-4 · Cited by 71
“97 [24]), sedentary behaviour (compared to ActivPAL: Charge 3 ICC = 0.”
BackgroundComputational Sleep Behavior Analysis: A Survey
Fallmann, S., & Chen, L. (2019) · IEEE Access · doi:10.1109/access.2019.2944801 · Cited by 61
“For Misfit Shine and Basis, light and deep sleep can be distinguished, and a comparison reveals that Basis performs more accurately than Misfit Shine [52].”
BackgroundCook, J. D., Eftekari, S. C., Dallmann, E., Sippy, M., & Plante, D. T. (2018) · Journal of Sleep Research · doi:10.1111/jsr.12789 · Cited by 59
Danzig, R., Wang, M., Shah, A. J., & Trotti, L. M. (2019) · Journal of Sleep Research · doi:10.1111/jsr.12926 · Cited by 64
Teo, J. X., Dávila, S., Yang, C., Hii, A. A., Pua, C. J., Yap, J. J. L., Tan, S. Y., Sahlén, A., Chin, C. W.-L., Teh, B. T., et al. (2019) · Communications Biology · doi:10.1038/s42003-019-0605-1 · Cited by 64
Anderson, K. N. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.01.35 · Cited by 53
Validation of Fitbit Inspire 2TM Against Polysomnography in Adults Considering Adaptation for Use
Lim, S. E., Kim, H. S., Lee, S. W., Bae, K.-H., & Baek, Y. (2023) · Nature and Science of Sleep · doi:10.2147/nss.s391802 · Cited by 57
“In a previous study that compared Withings Pulse O2 with PSG in 40 healthy adults, light sleep (average bias of 79 min) was also underestimated, which is similar to the results of this study.(28) The sensitivity of the participants for the total sleep stage of FBI2 was 93.”
ResultSamson, S., Konty, K., Lee, W.-N., Quisel, T., Foschini, L., Kerr, D. E., Liška, J., MILLS, H. G., Hollingsworth, R. C., Greenberg, M. E., et al. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819883340 · Cited by 54
“Thus far, most research on PGHD has been limited to small sample populations or has used simulated, nonreal-world scenarios to test device accuracy and reliability.(17-19) The aim of this study was to use PGHD linked with conventional real-world medical claims information to describe the effects on sleep, activity, an…”
BackgroundVarma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12795 · Cited by 54
Dong, X., Yang, S., Guo, Y., Lv, P., Wang, M., & Li, Y. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275287 · Cited by 49
Peach, H. D., Gaultney, J. F., & Ruggiero, A. R. (2018) · The Journal of Primary Prevention · doi:10.1007/s10935-018-0526-7 · Cited by 55
Cook, J. D., Prairie, M. L., & Plante, D. T. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7120 · Cited by 50
Svensson, T., Chung, U., Tokuno, S., Nakamura, M., & Svensson, A. K. (2019) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2019.109822 · Cited by 56
Gruwez, A., Libert, W., Ameye, L., & Bruyneel, M. (2017) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2017.03.008 · Cited by 45
O’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
Whibley, D., Braley, T. J., Kratz, A. L., & Murphy, S. L. (2019) · Journal of Pain · doi:10.1016/j.jpain.2019.04.011 · Cited by 51
Giurgiu, M., Timm, I., Becker, M. L., Schmidt, S., Wunsch, K., Nissen, R., Davidovski, D., Bussmann, J. B. J., Nigg, C. R., Reichert, M., et al. (2022) · JMIR mhealth and uhealth · doi:10.2196/36377 · Cited by 54
Laboratory and home comparison of wrist-activity monitors and polysomnography in middle-aged adults
Dunican, I. C., Murray, K., Slater, J. A., Maddison, K. J., Jones, M. J., DAWSON, B. T., Straker, L. M., Caldwell, J. A., Halson, S. L., & Eastwood, P. R. (2017) · Sleep and Biological Rhythms · doi:10.1007/s41105-017-0130-x · Cited by 50
“A benefit of such an automated algorithm is that they are not reliant on the input of subjective data and thus not influenced by the potential variability associated with this [32].”
BackgroundMethodInfluentialA systematic review of the performance of actigraphy in measuring sleep stages
Yuan, H., Hill, E. A., Kyle, S. D., & Doherty, A. (2024) · Journal of Sleep Research · doi:10.1111/jsr.14143 · Cited by 55
Speier, W. F., Dzubur, E., Zide, M., SHUFELT, C. L., Joung, S. Y., Eyk, J. E. V., Merz, C. N. B., Lopez, M., Spiegel, B. M. R., & Arnold, C. W. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy067 · Cited by 49
Yuan, H., Plekhanova, T., Walmsley, R., Reynolds, A. C., Maddison, K. J., Bucan, M., Gehrman, P., Rowlands, A., Ray, D. W., Bennett, D., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01065-0 · Cited by 40
Driller, M. W., Dixon, Z. T., & Clark, M. (2017) · Sport Sciences for Health · doi:10.1007/s11332-017-0373-6 · Cited by 53
Grandner, M. A., & Rosenberger, M. E. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815373-4.00012-5 · Cited by 50
Varma, N., Cygankiewicz, I., Turakhia, M. P., Heidbüchel, H., Hu, Y., Chen, L. Y., Couderc, J., Cronin, E. M., Estep, J. D., Grieten, L., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12461 · Cited by 39
Liang, Z., & Ploderer, B. (2020) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3380994 · Cited by 41
“Many studies have examined the validity and reliability of these devices in laboratories [18, 19, 21, 63, 70] and in participants’ own living environment [55].”
BackgroundPhysical Activity and Sleep Patterns in Hemodialysis Patients in a Suburban Environment
Williams, S., Han, M., Ye, X., Zhang, H., Meyring-Wösten, A., Bonner, M., Young, C., Thijssen, S., Marsh, D., & Kotanko, P. (2017) · Blood Purification · doi:10.1159/000452751 · Cited by 43
Pediatric Videosomnography: Can Signal/Video Processing Distinguish Sleep and Wake States?
Schwichtenberg, A. J., Choe, J., Kellerman, A., Abel, E. A., & Delp, E. J. (2018) · Frontiers in Pediatrics · doi:10.3389/fped.2018.00158 · Cited by 35
“(35) assessed agreement between PSG and several actigraphy devices and reported high correlations for many of their comparisons; however, as the current study demonstrates, high correlations do not equate high agreement.”
Kubala, A. G., Gibbs, B. B., Buysse, D. J., Patel, S. R., Hall, M. H., & Kline, C. E. (2019) · Behavioral Sleep Medicine · doi:10.1080/15402002.2019.1651316 · Cited by 37
“Similar to other reports, we also evaluated the number of device failures (Baroni, Bruzzese, Di Bartolo, & Shatkin, 2016; Mantua et al., 2016).”
ResultFazio, R. D., Cafagna, D., Marcuccio, G., Minerba, A., & Visconti, P. (2020) · Energies · doi:10.3390/en13092161 · Cited by 38
Actigraphy in studies on insomnia: Worth the effort?
Rösler, L., van der Lande, G., Leerssen, J., Cox, R., Ramautar, J. R., & Someren, E. J. W. V. (2022) · Journal of Sleep Research · doi:10.1111/jsr.13750 · Cited by 37
Sleep extension reduces fatigue in healthy, normally-sleeping young adults
Mantua, J., Skeiky, L., Prindle, N. E., Trach, S. K., Doty, T. J., Balkin, T. J., Brager, A. J., Capaldi, V. F., & Simonelli, G. (2019) · Sleep Science · doi:10.5935/1984-0063.20190056 · Cited by 38
“Impact of sleep on mood As shown in Table 2, counter to predictions, there was no detectable effect of sleep extension on mood ratings (vigor: (t(26) = 1.”
BackgroundSelf-citationClassifying sleep–wake stages through recurrent neural networks using pulse oximetry signals
Casal, R., Persia, L. E. D., & Schlotthauer, G. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102195 · Cited by 36
Gorzelitz, J., Farber, C., Gangnon, R. E., & Cadmus‐Bertram, L. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0072 · Cited by 41
Assessing the performance of a commercial multisensory sleep tracker
Mouritzen, N. J., Larsen, L. H., Lauritzen, M. H., & Kjær, T. W. (2020) · PLoS ONE · doi:10.1371/journal.pone.0243214 · Cited by 40
“Positive mean differences denote GV4 underestimation of sleep parameters and vice versa as in previous validation studies [12, 14, 23, 24].”
BackgroundResultDeep Sleep and Beeps: Sleep Quality Improvement Project in General Surgery Patients
Allen, R. W., Burney, C. P., Davis, A., Henkin, J. R., Kelly, J., Judd, B. G., & Ivatury, S. J. (2021) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2021.02.010 · Cited by 39
How Infant and Toddlers’ Media Use Is Related to Sleeping Habits in Everyday Life in Italy
Bellagamba, F., Presaghi, F., Marco, M. D., D’Abundo, E., Blanchfield, O. A., & Barr, R. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2021.589664 · Cited by 41
“However, it is important to note that parents often underestimate nighttime wakings, and we did not collect actigraphy data, which is the “gold standard” for monitoring sleep and a future direction for this work (Mantua et al., 2016; Sadeh, 2004).”
MethodDevine, J. K., Chinoy, E. D., Markwald, R. R., Schwartz, L. P., & Hursh, S. R. (2020) · Sensors · doi:10.3390/s21010076 · Cited by 32
Objective assessment of sleep quality in patients with rotator cuff tears
Ansok, C. B., Khalil, L. S., & Muh, S. J. (2019) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2019.09.033 · Cited by 34
Shaik, M. A., Anik, F. I., Hasan, M. M., Chakravarty, S., Ramos, M. D., Rahman, M. A., Ahamed, S. I., & Sakib, N. (2025) · JMIR Aging · doi:10.2196/69175 · Cited by 37
Topalidis, P. I., Florea, C., Eigl, E., Kurapov, A., Leon, C. A. B., & Schabus, M. (2021) · Sensors · doi:10.3390/s21113774 · Cited by 37
“[16], for example, found no difference between a research-based actigraph and PSG in total-sleep-time and sleep efficiency (see also Lüdtke et al.”
BackgroundDiagnosis of sleep and circadian rhythm disorder
Anderson, K. N. (2020) · doi:10.1093/med/9780198713005.003.0110 · Cited by 29
Doryab, A., Dey, A. K., Kao, G., & Low, C. A. (2019) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3314395 · Cited by 34
“Studies in [54] and [35] have also explored the capability of personal tracking devices to measure sleep compared to gold standards such as polysomnography.”
BackgroundAssessing Physical Activity and Sleep in Axial Spondyloarthritis: Measuring the Gap
Deodhar, A. A., Gensler, L. S., Magrey, M., Walsh, J. A., Winseck, A., Grant, D., & Mease, P. J. (2019) · Rheumatology and Therapy · doi:10.1007/s40744-019-00176-5 · Cited by 32
Actigraphy combined with EEG compared to polysomnography in sleep apnea patients
Fietze, I., Penzel, T., Partinen, M., Sauter, J., Küchler, G., Suvoro, A., & Hein, H. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/385 · Cited by 33
Sleep Fragmentation and Cognitive Trajectories After Critical Illness
Wilcox, M. E., McAndrews, M. P., Van, J., Jackson, J. C., Pinto, R. L., Black, S. E., Lim, A. S. P., Friedrich, J. O., & Rubenfeld, G. D. (2020) · CHEST Journal · doi:10.1016/j.chest.2020.07.036 · Cited by 33
HARU Sleep: A Deep Learning-Based Sleep Scoring System With Wearable Sheet-Type Frontal EEG Sensors
Matsumori, S., Teramoto, K., Iyori, H., Soda, T., Yoshimoto, S., & Mizutani, H. (2022) · IEEE Access · doi:10.1109/access.2022.3146337 · Cited by 31
“Several studies have validated commercial actigraph devices such as Fitbit and GARMIN [6], [7].”
BackgroundRahimi-Eichi, H., Coombs, G., Bustamante, C. M. V., Onnela, J.-P. “., Baker, J. T., & Buckner, R. L. (2021) · JMIR mhealth and uhealth · doi:10.2196/29849 · Cited by 30
Shifting From Active to Passive Monitoring of Alzheimer Disease: The State of the Research
Popp, Z., Low, S., Igwe, A., Rahman, S., Kim, M., Khan, R., Oh, E., Kumar, A., Anda‐Duran, I. D., Ding, H., et al. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.123.031247 · Cited by 34
“Weihs et al, 2022 28 Thomas et al 2021 29 Khosroazad et al, 2023 30 Mantua et al, 2016 31 Suzuki et al 2007 32 Khosroazad et al, 2023 30 Hsu et al, 2017 33 Au-Yeung et al, 2022 34 Physical activity Liang et al, 2010 35 VandeBunte et al, 2022 36 Bangen et al, 2023 37 Suzuki and Murase, 2010 38…”
Background
Metadata
- Authors
- Mantua, J., Gravel, N., & Spencer, R.
- Affiliations
- University of Massachusetts Amherst (US)
- Corresponding author
- Spencer, Rebecca
- ORCID
- Spencer, Rebecca
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-05-05
- Volume
- 16
- Issue
- 5
- Pages
- 646
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4883337
- OpenAlex
- W2346707803
- Cited by
- 314
- References
- 24
- Citations by year
- 2026: 12 · 2025: 21 · 2024: 23 · 2023: 32 · 2022: 22 · 2021: 35 · 2020: 47 · 2019: 60 · 2018: 30 · 2017: 29 · 2016: 2
- FWCI
- 57.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Scholarworks (University of Massachusetts Amherst) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- ScholarWorks@UMassAmherst (University of Massachusetts Amherst) (submittedVersion, cc-by)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
- Keywords
- sleep monitoring, wearable devices, actigraphy, polysomnography, device validity, total sleep time, sleep efficiency, light sleep, slow-wave sleep, NREM sleep, REM sleep, Fitbit, misfit
- MeSH terms
- Humans, Sleep, Wrist, Reproducibility of Results, Polysomnography, Actigraphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.