Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Polysomnography (PSG) is the “gold standard” for monitoring sleep. Alternatives to PSG are of interest for clinical, research, and personal use. Wrist-worn actigraph devices have been utilized in research settings for measures of sleep for over two decades. Whether sleep measures from commercially available devices are similarly valid is unknown. We sought to determine the validity of five wearable devices: Basis Health Tracker, Misfit Shine, Fitbit Flex, Withings Pulse O2, and a research-based actigraph, Actiwatch Spectrum. We used Wilcoxon Signed Rank tests to assess differences between devices relative to PSG and correlational analysis to assess the strength of the relationship. Data loss was greatest for Fitbit and Misfit. For all devices, we found no difference and strong correlation of total sleep time with PSG. Sleep efficiency differed from PSG for Withings, Misfit, Fitbit, and Basis, while Actiwatch mean values did not differ from that of PSG. Only mean values of sleep efficiency (time asleep/time in bed) from Actiwatch correlated with PSG, yet this correlation was weak. Light sleep time differed from PSG (nREM1 + nREM2) for all devices. Measures of Deep sleep time did not differ from PSG (SWS + REM) for Basis. These results reveal the current strengths and limitations in sleep estimates produced by personal health monitoring devices and point to a need for future development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Several studies have reported similar findings for the Fitbit Flex™ device (Montgomery-Downs et al., 2012; Mantua et al., 2016; Kang et al., 2017).”
From A Critical Review of Consumer Wearables, Mobile Applications, and Equipment for Providing Biofeedback, Monitoring Stress, and Sleep in Physically Active Populations (2018) · cites this paper as Mantua et al., 2016
In the citing paper
“sleep assessment algorithms are frequently proprietary and validated in small populations, making their measurement validity unclear5–8”
From Self-supervised learning of accelerometer data provides new insights for sleep and its association with mortality (2024) · cites this paper as [5]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · Cited by 6,530
Ohayon, M. M., Carskadon, M. A., Guilleminault, C., & Vitiello, M. V. (2004) · Sleep · doi:10.1093/sleep/27.7.1255 · Cited by 3,349
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415 · cited 2×
“it relies on hand-scored data using participant diaries of events (bedtime/wake time and time in bed; [8,9]).”
BackgroundMethodSystematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Marino, M., Li, Y., Rueschman, M. N., Winkelman, J. W., Ellenbogen, J. M., Solet, J. M., Dulin, H., Berkman, L. F., & Buxton, O. M. (2013) · Sleep · doi:10.5665/sleep.3142 · Cited by 1,056 · cited 1×
“The high reliability of the Actiwatch Spectrum for estimating TST is consistent with other studies [12].”
ResultWearable Devices as Facilitators, Not Drivers, of Health Behavior Change
Patel, M. S., Asch, D. A., & Volpp, K. G. (2015) · JAMA · doi:10.1001/jama.2014.14781 · Cited by 808 · cited 1×
“These commercially available products have begun to overcome limitations in cost (as low as $60) and usability, and have been validated several times in the area of physical activity [3–6].”
BackgroundFerguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · cited 1×
“These commercially available products have begun to overcome limitations in cost (as low as $60) and usability, and have been validated several times in the area of physical activity [3–6].”
BackgroundReliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360 · cited 1×
“These commercially available products have begun to overcome limitations in cost (as low as $60) and usability, and have been validated several times in the area of physical activity [3–6].”
BackgroundExploring Goal-setting, Rewards, Self-monitoring, and Sharing to Motivate Physical Activity
Munson, S., & Consolvo, S. (2012) · Proceedings of the 6th International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2012.248691 · Cited by 355 · cited 1×
“Personal health monitoring devices have rapidly gained popularity in the general public, providing the potential to improve feedback and motivation [1,2] towards improvements in physical activity, dietary intake, and sleep.”
Background
Cited by
Items 201–300 of 312
Kelly-Schuette, K. A., Shaker, T. M., Carroll, J., Davis, A. T., Wright, G. P., & Chung, M. H. (2020) · Journal of Graduate Medical Education · doi:10.4300/jgme-d-20-00304.1 · Cited by 7
Maynard, T. R., Appleman, E. R., Cronin‐Golomb, A., & Neargarder, S. A. (2021) · Exploration of Targeted Anti-tumor Therapy · doi:10.37349/emed.2021.00057 · Cited by 11
“Actigraphy bracelets have been valuable in calculating both TST and sleep efficiency [22], having been employed by researchers to measure sleep for decades [23, 24].”
Varma, N., Cygankiewicz, I., & Turakhia, M. P. (2021) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2021-4420 · Cited by 7
Clark, M., & Driller, M. W. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0034 · Cited by 7
Use of a Personal Sleep Self-Monitoring Device for Sleep Self-Management: A Feasibility Study
Torossian, M., LeBlanc, R., & Jacelon, C. S. (2020) · Journal of Gerontological Nursing · doi:10.3928/00989134-20201209-02 · Cited by 6
“However, PSMD technology is has shortcomings when compared to the gold-standard of polysomnography (PSG) (Mantua et al., 2016), especially in groups with existing self-reported sleep disturbances.”
BackgroundBliwise, D. L., Chapple, C. R., Maislisch, L., Roitmann, E., & Burtea, T. (2020) · SLEEP · doi:10.1093/sleep/zsaa141 · Cited by 7
“Additionally, the wearables were associated with a 6% absolute discrepancy (about 24 minutes) from PSG-based TST [6].”
BackgroundMethodResultInfluentialDayyani, F., Chu, C. H., Abedi, A., & Khan, S. S. (2024) · Algorithms · doi:10.3390/a17090383 · Cited by 7
Carlozzi, N. E., Troost, J. P., Sen, S., Choi, S. W., Wu, Z., Miner, J. A., Lombard, W. L., GRAVES, C. M., & Sander, A. M. (2025) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2024.12.022 · Cited by 5
Xu, T. Y., Zhang, Y., & Zhao, S. L. (2024) · Journal of Digestive Diseases · doi:10.1111/1751-2980.13328 · Cited by 8
“Actigraphy, using a wearable device with potentially high accuracy [36], can also provide an objective assessment of sleep quality, but the quality of commercial devices is uneven [37] and it is difficult to have uniform standards for different algorithms.”
Exploiting Wearable Technologies to Measure and Predict Students’ Effort
Moissa, B., Bonnin, G., & Boyer, A. E. (2019) · Springer eBooks · doi:10.1007/978-3-319-64301-4_19 · Cited by 8
Hawkins, M., Iradukunda, F., & Paterno, M. T. (2019) · JMIR Research Protocols · doi:10.2196/12455 · Cited by 7
“The Shine 2 has been shown to provide equivalent estimates of total sleep time as in-lab polysomnography ( r =.87), the gold standard for sleep assessment [31].”
Consumer Technology for Sleep-Disordered Breathing: a Review of the Landscape
Rosa, T. D., Zitser, J., & Capasso, R. (2019) · Current Otorhinolaryngology Reports · doi:10.1007/s40136-019-00222-4 · Cited by 5
Sasaki-Otomaru, A., Yamasue, K., Tochikubo, O., Saito, K., & Inamori, M. (2019) · Clinical and Experimental Hypertension · doi:10.1080/10641963.2019.1590382 · Cited by 5
“Apparently, the commercially available devices for measuring sleep have both strengths and limitations (16).”
BackgroundWearables with Heart Rate Monitors and Dynamic Workout Plans
Ferreira, A. E. N., Coelho, J., & Nogueira, N. (2018) · International Wireless Communications and Mobile Computing Conference (IWCMC) · doi:10.1109/iwcmc.2018.8450275 · Cited by 5
“The accuracy of these devices is discussed, for example in [20], [25], [32], [35] and the results show”
BackgroundEsteves, A. M., Pancotto, H. P., & Silva, A. N. (2019) · Brazilian Journal of Motor Behavior · doi:10.20338/bjmb.v13i4.132 · Cited by 6
Pascoe, M., Wollet, A. R., Minyety, J. D. L. C., Vera, E. M., Miller, H., Celiku, O., Leeper, H. E., Fernandez, K., Reyes, J., Young, D., et al. (2024) · Neuro-Oncology Practice · doi:10.1093/nop/npae048 · Cited by 4
Grau, L., Arbet, J., Ostendorf, D. M., Blankenship, J. M., Panter, S. L., Catenacci, V. A., Melanson, E. L., & Creasy, S. A. (2022) · Sleep Science · doi:10.5935/1984-0063.20220052 · Cited by 4
“Specifically, Mantua et al. (2016) 17 found that the Actiwatch Spectrum and several consumer-grade wearable devices, including models from Fitbit, Misfit, Basis, and Withings, produced similar estimates of TST compared to PSG.”
ResultAssociation of disrupted sleep with 24-hour blood pressure variability in caregivers
Ahn, S., Howie‐Esquivel, J., Davis, E. M., Chung, M. L., Lobo, J. M., & Logan, J. G. (2023) · Heart & Lung · doi:10.1016/j.hrtlng.2023.02.024 · Cited by 5
Evaluation of sound-based sleep stage prediction in shared sleeping settings
Kim, J., Kim, S., Cho, E., Kyung, H., Park, S., Hong, J., Lee, D., Oh, J., & Yoon, I. (2025) · Sleep Medicine · doi:10.1016/j.sleep.2025.106533 · Cited by 5
Naps Do Not Change Delay Discounting Behavior in Young Adults
O’Connor, S., Sonni, A., Karmarkar, U. R., & Spencer, R. M. C. (2018) · Frontiers in Psychology · doi:10.3389/fpsyg.2018.00921 · Cited by 4
Self-citationConcurrent validity of Nokia Go activity tracker in walking and free‐living conditions
Lebleu, J., Detrembleur, C., Guebels, C., Hamblenne, P., & Valet, M. (2019) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.13125 · Cited by 4
The Home-Based Sleep Laboratory
Hanein, Y., & Mirelman, A. (2021) · Journal of Parkinson s Disease · doi:10.3233/jpd-202412 · Cited by 5
Li, J., Sun, M., Zhao, Z., Li, X., Li, G., Wu, C., Qian, K., Hu, B., Yamamoto, Y., & Schuller, B. W. (2023) · EURASIP Journal on Audio Speech and Music Processing · doi:10.1186/s13636-023-00309-3 · Cited by 4
“…of OSA, PSG has limitations including high cost, inconvenience in terms of portability, high application difficulty, and unsuitability for large-scale population screening, as well as its primary focus on snoring loudness and frequency rather than analysis of snoring characteristics [11, 12].”
BackgroundLee, H., Lee, H., & Lim, H. (2023) · Journal of Family Nursing · doi:10.1177/10748407231157406 · Cited by 5
“Actigraphy has been widely used in sleep studies as a non-invasive and cost-effective tool because it provides objective and consistent results for various sleep-related indexes (Mantua et al., 2016; Smith et al., 2018).”
MethodSleep Detection Using Physiological Signals from a Wearable Device
Assaf, M., Rizzotti-Kaddouri, A., & Punceva, M. (2019) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-30335-8_3 · Cited by 4
Jumabhoy, R., Maskevich, S., Dap, P., Anderson, C., Stout, J. C., & Drummond, S. P. A. (2019) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/mx2ae · Cited by 5
Rahimi, M. M., Phillips, C. L., Marshall, N. S., Wassing, R., Pun, T. B., Grunstein, R. R., & Gordon, C. J. (2025) · Sleep And Breathing · doi:10.1007/s11325-025-03326-y · Cited by 3
“Actigraphy, which uses a wrist-worn accelerometer to measure sleep-wake patterns, has been shown to overestimate total sleep time (TST) and wake after sleep onset (WASO) [1, 2].”
Li, Q., Lv, W., Yuwen, W., Jia, Z., Li, X., & Guo, J. (2025) · Sleep Medicine · doi:10.1016/j.sleep.2025.106597 · Cited by 3
Obeidat, B., Hamdan, R. M. A., & Hayajneh, A. A. (2025) · Scientific Reports · doi:10.1038/s41598-025-17351-0 · Cited by 4
Marquard, J. L., Howard, J., & LeBlanc, R. (2023) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000000970 · Cited by 4
A Real-Time Sleep Monitoring System Based on Fiber Optic Sensor
Chen, T., Lyu, W., Chen, S., & Yu, C. (2024) · Asia Communications and Photonics Conference · doi:10.1109/acp/ipoc63121.2024.10810038 · Cited by 3
“In clinical sleep monitoring, polysomnography (PSG) is currently the gold standard for diagnosing sleep disorders [3].”
Do Patients Sleep Better at Home or in the Hospital Following Primary Total Joint Arthroplasty?
Liao, G. Y., Chansky, H. A., Manner, P. A., Brinkmann, E. J., Fernando, N. D., & Hernandez, N. M. (2025) · The Journal of Arthroplasty · doi:10.1016/j.arth.2025.05.020 · Cited by 3
Automatic sleep staging from pulse oximeter using RNN
Casal, R., Persia, L. E. D., & Schlotthauer, G. (2021) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco54536.2021.9616157 · Cited by 5
Cook, S., Wood, E. P., Rodrigues, M., Caldas, J. J., & Delorme, M. (2024) · JMIR Formative Research · doi:10.2196/52195 · Cited by 3
“For instance, research has found that a period of at least 3-5 days is necessary to capture accurate information pertaining to sleep [27].”
BackgroundMethodInfluentialShedding light to sleep studies
Bozkurt, A. Y., Dieffenderfer, J. P., & Krystal, A. D. (2017) · Biosensing and Nanomedicine · doi:10.1117/12.2275625 · Cited by 3
Nelson, E. C., de Keijzer, R., Vollenbroek-Hutten, M. M. R., Verhagen, T., & Noordzij, M. L. (2019) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-030-34833-5_24 · Cited by 5
Current AI applications in medical therapies and services
Catania, L. J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-824477-7.00013-4 · Cited by 3
Simultaneous Measurements Reading from More Than One MiBand 3 Wristbands
Rodak, Z., Tokarz, K., Mielnik, P., & Fojcik, M. (2022) · Lecture notes in networks and systems · doi:10.1007/978-981-16-6309-3_10 · Cited by 3
Yuan, H., Plekhanova, T., Walmsley, R., Reynolds, A. C., Maddison, K. J., Bucan, M., Gehrman, P., Rowlands, A., Ray, D. W., Bennett, D., et al. (2023) · doi:10.1101/2023.07.07.23292251 · Cited by 3
Jemere, T., van der Mei, I. A. F., Honan, C. A., Taylor, B. V., Campbell, J. A., Breslin, M. C., & Laslett, L. L. (2026) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2026.107136 · Cited by 2
James, P., & Redline, S. S. (2019) · Springer eBooks · doi:10.1007/978-3-030-20992-6_3 · Cited by 2
All-night spectral and microstate EEG analysis in patients with recurrent isolated sleep paralysis
Černý, F., Piorecká, V., Kliková, M., Kopřivová, J., Bušková, J., & Piorecký, M. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1321001 · Cited by 2
“Even though RISP is mainly associated with the REM phase, previous studies analyzed the REM and NREM together [26, 27, 28].”
BackgroundValidity of Fitbit Flex® consumer device on the sleep evaluation
López-Flores, M., Fernandez, A. R., Villa-Vicente, J., Iglesias, D. S., & Marroyo, J. A. R. (2020) · Cultura Ciencia y Deporte · doi:10.12800/ccd.v15i43.1397 · Cited by 2
“Sin embargo, existen correlaciones moderadas-altas en las mediciones de ES y TTS entre FF y otros actigrafos (Mantua et al., 2016; Kang et al., 2017).”
BackgroundMantua, J., Gutiérrez, R. L., Isidean, S. D., Alcala, A. N., Testa, K. J., Talaat, K. R., Doty, T. J., & Porter, C. K. (2022) · Sleep Medicine · doi:10.1016/j.sleep.2022.09.008 · Cited by 2
Self-citationMunno, R., Thomson, K. M., & Zonneveld, K. L. M. (2022) · Behavioral Interventions · doi:10.1002/bin.1918 · Cited by 3
Smartphones and Consumer Devices in Management of Obstructive Sleep Apnea
Singh, K., Jain, A., Panchal, I., Madan, H., Chaturvedi, S., Kostojchin, A., Shahzadi, A., Khan, M. M., & Piplani, S. (2023) · Indian Journal of Sleep Medicine · doi:10.5005/jp-journals-10069-0108 · Cited by 3
Acute Changes in Sleep Stages After Concussion in Collegiate Athletes: A Pilot Study
Donahue, C. C., Barnes, L. E., Hertel, J. N., & Resch, J. E. (2025) · Journal of Athletic Training · doi:10.4085/1062-6050-0629.24 · Cited by 2
Considering interpersonal differences in validating wearable sleep-tracking technologies
Liang, Z., & Martell, M. A. C. (2017) · International Conference on Mobile Computing and Ubiquitous Network (ICMU) · doi:10.23919/icmu.2017.8330096 · Cited by 2
“Most of the work in literature assumes that the accuracy of these devices is consistent across individuals [3].”
BackgroundOhlenforst, B., Seth, L., Aalmoes, R., Schreckenberg, D., & van Miltenburg, M. (2020) · Transactions of the Institute of Aviation · doi:10.2478/tar-2020-0018 · Cited by 4
“Polysomnography) and found that the activity trackers did not differ much from the control [10] [11] [12] [13] [14].”
BackgroundWearable Technology Adaptation to Aviation Cabin Crew’s Fatigue Assessments
Çevik, İ., & Dahanayake, A. (2021) · Lecture notes in networks and systems · doi:10.1007/978-3-030-68476-1_23 · Cited by 4
Technologies in the Pediatric Sleep Lab: Present and Future
Etzioni, T., & Pillar, G. (2021) · Springer eBooks · doi:10.1007/978-3-030-65574-7_15 · Cited by 2
Sleep in Hospitalized Patients
Knauert, M. P., & Pisani, M. A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813014-8.00019-6 · Cited by 5
Multiple-signal artificial pancreas systems
Patek, S. D. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00019-3 · Cited by 3
Periodic Limb Movements Detection through Actigraphy Signal Analysis
Zaretskiy, A. P., Mityagin, K. S., Tarasov, V. S., & Moroz, D. N. (2019) · International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon) · doi:10.1109/fareastcon.2019.8934102 · Cited by 2
“Preliminarily, it’s important to exclude from the raw signal low-frequency trend with adaptive digital filtering and move to the analysis of stationary random process at the initial stage in view of the fact to the non-stationarity of the analyzed processes [8].”
BackgroundActigraphy versus Polysomnography to Identify Changes in the Sleep Patterns of Adults with Insomnia
Garcia, A. D. S., Neves, J. D., Vicentini, S. C., Nogueira, G. D. A., Marques, J. M., Barreiros, R. N., Marta, C. B., da Silva, R. C. L., & da Silva, C. R. L. (2020) · Revista Neurociências · doi:10.34024/rnc.2020.v28.10600 · Cited by 3
Crimarco, A. E., Turner‐McGrievy, G. M., & Wright, M. (2018) · Journal of Technology in Behavioral Science · doi:10.1007/s41347-018-0060-8 · Cited by 1
“…that validated the Misfit and other sleeping devices to polysomnography indicated that although the Misfit had strong correlations for total sleep time and minutes of deep sleep, minutes of light sleep were underestimated by an average of 79 min relative to the polysomnography (Mantua et al. 2016).”
ResultCharacterization of sleep efficiency transitions in family caregivers
Ahn, S., Lobo, J. M., Davis, E. M., Howie‐Esquivel, J., Chung, M. L., & Logan, J. G. (2023) · Journal of Behavioral Medicine · doi:10.1007/s10865-023-00461-3 · Cited by 2
“Actigraphy has shown high reliability compared with polysomnography, the gold standard measure of sleep, and has been widely used and validated to measure sleep parameters (Mantua et al., 2016; Marino et al., 2013).”
Choe, J., Oh, Y., Park, C., Kim, Y., Wang, C., & Min, S. D. (2025) · Scientific Reports · doi:10.1038/s41598-025-32036-4 · Cited by 3
“Sleep efficiency is a relatively quantitative and reliable indicator that can compensate for the limitations of self-reported sleep assessments and is frequently used in sleep research 15,16 .”
Kore, R., Boyer, V., Reichenberger, D., Mundinger, J. J., Chang, A. M., & DURMUŞ, D. (2026) · npj Biological Timing and Sleep · doi:10.1038/s44323-026-00088-y · Cited by 1
Sleep disturbances in specific learning disorders: a qualitative and quantitative investigation
Pecini, C., Giuntoli, I., Spoglianti, S., Lieto, M. D., Inguaggiato, E., Gasperini, F., Cristofani, P., Brizzolara, D., Chilosi, A. M., Faraguna, U., et al. (2020) · Minerva Pediatrics · doi:10.23736/s0026-4946.20.05505-x · Cited by 2
Optimizing Behavioral Sleep Strategies
Ong, J. C., & Gamaldo, C. E. (2020) · CONTINUUM Lifelong Learning in Neurology · doi:10.1212/con.0000000000000876 · Cited by 1
Sherwani, S. I., & Bates, B. R. (2020) · Advances in information security, privacy, and ethics book series · doi:10.4018/978-1-7998-3487-8.ch002 · Cited by 2
McCall, C., & Watson, N. F. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815373-4.00010-1 · Cited by 1
Influence of Light Exposure on the Melanopsin Driven Pupil Response and Circadian Rhythm
Abbott, K. S. (2018) · Masters Thesis · Cited by 3
The potential of personal devices in large-scale sleep studies
Roomkham, S. (2020) · Queensland University of Technology · doi:10.5204/thesis.eprints.203907 · Cited by 2
Monitoring Sleep Disorders at Home: How can Wearable Electrode Arrays Help?
Hanein, Y., & Mirelman, A. (2020) · Bioelectronics in Medicine · doi:10.2217/bem-2020-0008 · Cited by 2
Nelson, B. W., Flannery, J., Duell, N., Flournoy, J. C., Prinstein, M. J., & Telzer, E. H. (2021) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/wvpt2 · Cited by 1
Bottenhorn, K. L., Salo, T., Peraza, J. A., Riedel, M. C., Flannery, J. S., Kimbler, A., Toll, A. L., Suarez, D., Cruz, F. M., Zagales, I., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.04.16.589598 · Cited by 1
Activity Tracking’s Newest Companion: Pulse Wave Velocity
Sandberg, K. L., Wright, S. P., & Umans, J. G. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11276
“Although total sleep time determined by the Withings Activité watch was validated by polysomnography, this device, similar to other consumer monitors, does not accurately assess sleep efficiency or sleep architecture, each of which predict health outcomes better than total sleep duration.(11) Additional challenges inc…”
MethodWilliams, J. A. (2017) · Research Exchange (Washington State University)
An Inter-Device Accuracy Comparison of Consumer Sleep Trackers
Zavrel, E. A., & Krieger, A. C. (2019) · Design of Medical Devices Conference (DMD) · doi:10.1115/dmd2019-3205
Thermal imaging developments for respiratory airflow measurement to diagnose apnoea
Usman, M. (2019) · Sheffield Hallam University · doi:10.7190/shu-thesis-00189
“Unavailability of clinicians with the ability of technical competency and the problematic procedure of overnight sleep study and also the problems with contact sensors as mentioned earlier require further developments in this area [41] [50].”
BackgroundWei, J. (2019) · UWSpace (University of Waterloo) · Cited by 1
A Home-Based IoT-Enabled Framework for Sleep Behaviour Assessment
Fallmann, S., Chen, L., & Chen, F. (2019) · IEEE Intl Conf on Dependable, Autonomic and Secure Computing, Intl Conf on Pervasive Intelligence and Computing, Intl Conf on Cloud and Big Data Computing, Intl Conf on Cyber Science and Technology Congress (DASC/PiCom/CBDCom/CyberSciTech) · doi:10.1109/dasc/picom/cbdcom/cyberscitech.2019.00018
“These factors are manifested in sensory data such as accelerometers from which basic sleep factors can be extracted such as sleep efficiency, sleep duration, sleep fragmentation, wake-after-sleep-onset and arousal [15], [17], [18] as well as more advanced ones like sleep stages [5] and sleep positions [20].”
BackgroundHarb, E. N. (2019) · eScholarship (California Digital Library)
Fitbit Sleep Measures in Children with and without Sleep Disordered Breathing
Don, D. M., Koempel, J. A., Fisher, L. M., & Osterbauer, B. (2018) · doi:10.36959/532/319
PUSHING THE BOUNDARIES OF CONSUMER GRADE WEARABLE DEVICES IN HEALTH CARE FOR OLDER ADULTS
Kim, B. Y. (2020) · UWSpace (University of Waterloo)
Rinaldi, R. (2016) · Cerveau & Psycho · doi:10.3917/cerpsy.080.0060
Silva, M. A., & Kemp, E. S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822963-7.00185-7
Sherwani, S. I., & Bates, B. R. (2022) · IGI Global eBooks · doi:10.4018/978-1-6684-6311-6.ch018
Adoption of Medical Technology in Public Healthcare Sector: An Evidence from Developing Country
Dahri, A. S., Jalbani, A. A., & Memon, S. B. (2022) · Springer eBooks · doi:10.1007/978-981-19-3116-1_9 · Cited by 1
Technologies to Assess Psycho-Behavioural Symptoms
Emmert, K., & Maetzler, W. (2023) · Practical issues in geriatrics · doi:10.1007/978-3-031-32246-4_8
Doherty, A., Yuan, H., Plekhanova, T., Walmsley, R., Reynolds, A., Maddison, K., Bucan, M., Gehrman, P., Rowlands, A., Ray, D., et al. (2023) · doi:10.21203/rs.3.rs-3275989/v1
Applications of AI in the psychological and psychiatric fields: what the experts offer us
Collecchia, G., & Gobbi, R. D. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-14054-9.00007-7
Evaluation of Nasal Conditions on Sleep: Integrating Wearable Tech in Surgical Outcomes
Kumar, S., Patra, A. K., & Deepthi, S. (2024) · Indian Journal of Otolaryngology and Head & Neck Surgery · doi:10.1007/s12070-024-04524-y
“Wearable sleep trackers, that are equipped with sensors capable of monitoring several factors like heart rate variability and movement, provide an extensive understanding of sleep cycles [5].”
Uddin, M. Z. (2024) · International Conference on Machine Learning Technologies (ICMLT) · doi:10.1145/3674029.3674039
“Wearable sensors offer the advantage of discreet and continuous monitoring of physiological signals, providing valuable insights into sleep patterns and quality in real-world settings [7].”
Nobue, A., Sano, K., & Ishikawa, M. (2024) · Sensors · doi:10.3390/s24216820 · Cited by 1
“While wristband-type devices may be less accurate in measuring sleep quality compared to traditional polysomnography (PSG) [33,34], recent studies have shown good agreement between Fitbit devices and PSG for various sleep parameters [15–17].”
ResultPsychiatric Illness Across the Menstrual Cycle
(2025) · Frontiers research topics · doi:10.3389/978-2-8325-6049-5
Zhao, B., Wang, W., Ji, Y., & Zheng, M. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3561154
“To achieve high reliability, participants need to individually record key parameters, and skilled researchers must score the data, which is labor-intensive and cannot provide real-time feedback [14].”
Park, J., Kim, J., Kim, H., Ahn, E. K., & Yoon, K. (2025) · Journal of Sleep Medicine · doi:10.13078/jsm.250001
“In contrast, previous studies investigating the validity of smartwatches have typically monitored sleep for a short duration, usually overnight 13,17,26,27 or for 48 hours.”
Khan, M. H., Ahmad, E., Alam, M., Farooq, O., Khan, Y. U., & Sarfraz, M. (2025) · International Conference on Cognitive Computing in Engineering, Communications, Sciences and Biomedical Health Informatics (IC3ECSBHI) · doi:10.1109/ic3ecsbhi63591.2025.10990519
“…of cardiac parameters in abdominal health assessment during goal-directed fluid therapy in high-risk abdominal surgery, and Mantua et al. [14] validated wrist-worn actigraphy devices for sleep monitoring—each emphasizing the promise offered by wearables to expand health monitoring…”
Unraveling the Sandman’s Mystery: Predicting and Explaining Sleep Quality Over Eight Years
Ford, A., Zhang, T., Dong, A., & Bae, S. W. (2025) · International Conference on Activity and Behavior Computing (ABC) · doi:10.1109/abc64332.2025.11118601 · Cited by 1
“The results have shown that the collected sleep data from the wearable, such as total sleep time (TST), bed-time, sleep latency, and heart rate, are in good agreement with the collected data from PSG [21]–[23].”
Sleep regularity and variability in wheelchair athletes: lockdown and return to sport
Sanz-Milone, V., Silva, A., Facundo, L. A., da Cunha, D. T., de Mello, M. T., & Esteves, A. M. (2025) · Brazilian Journal of Motor Behavior · doi:10.20338/bjmb.v19i1.479
Mummaneni, A., Amir, C., Allen, N. B., & Ho, T. C. (2025) · Biological Psychiatry Cognitive Neuroscience and Neuroimaging · doi:10.1016/j.bpsc.2025.10.002 · Cited by 1
Actigraphic sleep tracking and wearables
Grandner, M. A., & Rosenberger, M. E. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13954-3.00008-5
Ferguson, T., Curtis, R., Fraysse, F., Olds, T., Dumuid, D., Brown, W. J., Esterman, A., & Maher, C. A. (2023) · Figshare · doi:10.6084/m9.figshare.22623844
Ferguson, T., Curtis, R., Fraysse, F., Olds, T., Dumuid, D., Brown, W. J., Esterman, A., & Maher, C. A. (2023) · Figshare · doi:10.6084/m9.figshare.22623847
Jiang, T., Yin, X., Zhu, L., Jia, W., Tan, Z., Li, B., & Guo, J. (2023) · Figshare · doi:10.6084/m9.figshare.24741847
Metadata
- Authors
- Mantua, J., Gravel, N., & Spencer, R.
- Affiliations
- University of Massachusetts Amherst (US)
- Corresponding author
- Spencer, Rebecca
- ORCID
- Spencer, Rebecca
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2016-05-05
- Volume
- 16
- Issue
- 5
- Pages
- 646
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4883337
- OpenAlex
- W2346707803
- Cited by
- 314
- References
- 24
- Citations by year
- 2026: 12 · 2025: 21 · 2024: 23 · 2023: 32 · 2022: 22 · 2021: 35 · 2020: 47 · 2019: 60 · 2018: 30 · 2017: 29 · 2016: 2
- FWCI
- 57.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Scholarworks (University of Massachusetts Amherst) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- ScholarWorks@UMassAmherst (University of Massachusetts Amherst) (submittedVersion, cc-by)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Circadian rhythm and melatonin
- Keywords
- sleep monitoring, wearable devices, actigraphy, polysomnography, device validity, total sleep time, sleep efficiency, light sleep, slow-wave sleep, NREM sleep, REM sleep, Fitbit, misfit
- MeSH terms
- Humans, Sleep, Wrist, Reproducibility of Results, Polysomnography, Actigraphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.