CoChat

Sleep Monitoring Based on a Tri-Axial Accelerometer and a Pressure Sensor

Open access

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Sleep disorders are a common affliction for many people even though sleep is one of the most important factors in maintaining good physiological and emotional health. Numerous researchers have proposed various approaches to monitor sleep, such as polysomnography and actigraphy. However, such approaches are costly and often require overnight treatment in clinics. With this in mind, the research presented here has emerged from the question: “Can data be easily collected and analyzed without causing discomfort to patients?” Therefore, the aim of this study is to provide a novel monitoring system for quantifying sleep quality. The data acquisition system is equipped with multimodal sensors, including a three-axis accelerometer and a pressure sensor. To identify sleep quality based on measured data, a novel algorithm, which uses numerous physiological parameters, was proposed. Such parameters include non-REM sleep time, the number of apneic episodes, and sleep durations for dominant poses. To assess the effectiveness of the proposed system, three participants were enrolled in this experimental study for a duration of 20 days. From the experimental results, it can be seen that the proposed monitoring system is effective for quantifying sleep quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s16050750

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Process flow for sleep quality monitoring.
Figure 1 Process flow for sleep quality monitoring.CC BY · PubMed Central
Figure 2 Sleeping postures.
Figure 2 Sleeping postures.CC BY · PubMed Central
Figure 3 Our test-bed environment, (a) test-bed; (b) Polysomnography.
Figure 3 Our test-bed environment, (a) test-bed; (b) Polysomnography.CC BY · PubMed Central
Figure 4 Screenshots of the user interfaces and examples of signals obtained from the sleep quality monitoring system. Screenshots of user interfaces in the sleep quality monitoring system. (a) screenshots of user interfaces in the sleep quality monitoring system; (b) example signals obtained from the sleep quality monitoring system.
Figure 4 Screenshots of the user interfaces and examples of signals obtained from the sleep quality monitoring system. Screenshots of user interfaces in the sleep quality monitoring system. (a) screenshots of user interfaces in the sleep quality monitoring system; (b) example signals obtained from the sleep quality monitoring system.CC BY · PubMed Central
Figure 5 Example of signals obtained from the PSG.
Figure 5 Example of signals obtained from the PSG.CC BY · PubMed Central
Figure 6 Analog-to-digital converter (ADC) board. (a) ADC board; (b) architecture of ADC board.
Figure 6 Analog-to-digital converter (ADC) board. (a) ADC board; (b) architecture of ADC board.CC BY · PubMed Central
Figure 7 Heart rate variability and respiratory rate. (a) Raw data obtained from ADC (100 samples/s, 12-bit resolution); (b) Filtering data using an infinite impulse (IIR) filter for estimating the heart rate; (c) Filtering data using an infinite impulse (IIR) filter for estimating the respiratory rate; (d) Heart peak obtained from filtering data after noise reduction; (e) Selected heart peak.
Figure 7 Heart rate variability and respiratory rate. (a) Raw data obtained from ADC (100 samples/s, 12-bit resolution); (b) Filtering data using an infinite impulse (IIR) filter for estimating the heart rate; (c) Filtering data using an infinite impulse (IIR) filter for estimating the respiratory rate; (d) Heart peak obtained from filtering data after noise reduction; (e) Selected heart peak.CC BY · PubMed Central
Figure 8 Bland–Altman plot with a mean difference of 0.076 that shows the limit of agreement of 95% (dashed lines are mean differences ± the limit of agreement) between the continuous heart rate (HR) of pressure signal and its corresponding electro-cardiogram (ECG) signal.
Figure 8 Bland–Altman plot with a mean difference of 0.076 that shows the limit of agreement of 95% (dashed lines are mean differences ± the limit of agreement) between the continuous heart rate (HR) of pressure signal and its corresponding electro-cardiogram (ECG) signal.CC BY · PubMed Central
Figure 9 Results of the sleeping pose rate and sleeping pose detection. (a) Sleeping pose rate; (b) Sleeping pose detection.
Figure 9 Results of the sleeping pose rate and sleeping pose detection. (a) Sleeping pose rate; (b) Sleeping pose detection.CC BY · PubMed Central
Figure 10 Sleep apnea detection.
Figure 10 Sleep apnea detection.CC BY · PubMed Central
Figure 11 Results of the sleep stage classification.
Figure 11 Results of the sleep stage classification.CC BY · PubMed Central
Figure 12 Example of signals obtained from sensors in the presence of motion artifact. (a) Example of signals obtained from the PSG in the presence of motion artifact; (b) Example of signals obtained from an accelerometer sensor and a pressure sensor in the presence of motion artifacts.
Figure 12 Example of signals obtained from sensors in the presence of motion artifact. (a) Example of signals obtained from the PSG in the presence of motion artifact; (b) Example of signals obtained from an accelerometer sensor and a pressure sensor in the presence of motion artifacts.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Research works printed but not linked: 1

  1. Mack, D., Kell, S., Alwan, M., Turner, B., and Felder, R. (2003, January 25–29). Non-invasive analysis of physiological signals (naps): A vibration sensor that passively detects heart and respiration rates as part of a sensor suite for medical monitoring. Proceedings of the 2003 Summer Bioengineering Conference, Key Biscayne, FL, USA.

Cited by

See all 125

Metadata

Authors
Nam, Y., Kim, Y., & Lee, J.
Affiliations
  • Soonchunhyang University (KR)
  • Worcester Polytechnic Institute (US)
  • Wonkwang University (KR)
Corresponding author
Lee, Jinseok
Venue
Sensors
Publisher
MDPI AG
Published
2016-05-23
Volume
16
Issue
5
Pages
750
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2396951905
Cited by
124
References
25
Citations by year
2026: 5 · 2025: 9 · 2024: 18 · 2023: 15 · 2022: 13 · 2021: 15 · 2020: 15 · 2019: 14 · 2018: 11 · 2017: 8 · 2016: 1
FWCI
7.69
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Soonchunhyang University
  • Ministry of Science, ICT and Future Planning (IITP-2016-H8601-16-1009)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
sleep monitoring, sleep quality, triaxial accelerometer, pressure sensors, multimodal sensor data, apnea detection, sleep position, physiological parameters, wearable monitoring system
MeSH terms
Algorithms, Heart Rate, Humans, Monitoring, Physiologic, Respiration, Sleep Apnea Syndromes, Sleep Wake Disorders, Biosensing Techniques, Blood Pressure Monitors, Polysomnography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sleep Monitoring Based on a Tri-Axial Accelerometer and a Pressure Sensor. https://app.cochat.ai/papers/10.3390/s16050750
The paper
Nam, Y., Kim, Y., & Lee, J. (2016). Sleep Monitoring Based on a Tri-Axial Accelerometer and a Pressure Sensor. Sensors. https://doi.org/10.3390/s16050750

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.