Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

A Comprehensive Analysis on Wearable Acceleration Sensors in Human Activity Recognition

Open access
Janidarmian, Majid, Roshan Fekr, Atena, Radecka, Katarzyna, Zilic, Zeljko · 2017 · Sensors

Abstract

Sensor-based motion recognition integrates the emerging area of wearable sensors with novel machine learning techniques to make sense of low-level sensor data and provide rich contextual information in a real-life application. Although Human Activity Recognition (HAR) problem has been drawing the attention of researchers, it is still a subject of much debate due to the diverse nature of human activities and their tracking methods. Finding the best predictive model in this problem while considering different sources of heterogeneities can be very difficult to analyze theoretically, which stresses the need of an experimental study. Therefore, in this paper, we first create the most complete dataset, focusing on accelerometer sensors, with various sources of heterogeneities. We then conduct an extensive analysis on feature representations and classification techniques (the most comprehensive comparison yet with 293 classifiers) for activity recognition. Principal component analysis is applied to reduce the feature vector dimension while keeping essential information. The average classification accuracy of eight sensor positions is reported to be 96.44% ± 1.62% with 10-fold evaluation, whereas accuracy of 79.92% ± 9.68% is reached in the subject-independent evaluation. This study presents significant evidence that we can build predictive models for HAR problem under more realistic conditions, and still achieve highly accurate results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s17030529

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure A1 The list of the classifiers we explored in this paper. The numbers indicate the classifiers IDs.
Figure A1 The list of the classifiers we explored in this paper. The numbers indicate the classifiers IDs.CC BY · PubMed Central
Figure 1 Sensor-based activity recognition procedure.
Figure 1 Sensor-based activity recognition procedure.CC BY · PubMed Central
Figure 2 The pairwise scatter plots of the first four components.
Figure 2 The pairwise scatter plots of the first four components.CC BY · PubMed Central
Figure 3 The rectangular tree map that presents dense volumes of data in a space filling layout to see datasets contributions in each target position. Laying Down (LD), Ascending Stairs (AS), Descending Stairs (DS). The number inside each rectangle indicates the dataset number (see first column of Table 2).
Figure 3 The rectangular tree map that presents dense volumes of data in a space filling layout to see datasets contributions in each target position. Laying Down (LD), Ascending Stairs (AS), Descending Stairs (DS). The number inside each rectangle indicates the dataset number (see first column of Table 2).CC BY · PubMed Central
Figure 4 The minimum and maximum accuracy of each classifier over different window sizes, ranging from 1 s to 15 s, with the waist accelerometer data.
Figure 4 The minimum and maximum accuracy of each classifier over different window sizes, ranging from 1 s to 15 s, with the waist accelerometer data.CC BY · PubMed Central
Figure 5 The range of topClassifiers accuracies for (a) Waist; (b) RLA; (c) LLA; (d) RUL; (e) LUL; (f) RLL; (g) LLL; and (h) Chest.
Figure 5 The range of topClassifiers accuracies for (a) Waist; (b) RLA; (c) LLA; (d) RUL; (e) LUL; (f) RLL; (g) LLL; and (h) Chest.CC BY · PubMed Central
Figure 6 The rank of window sizes in providing the best accuracy in each position.
Figure 6 The rank of window sizes in providing the best accuracy in each position.CC BY · PubMed Central
Figure 7 Effect of window size to gain meaningful information for the activity classification in (a) 3D and (b) 2D representations.
Figure 7 Effect of window size to gain meaningful information for the activity classification in (a) 3D and (b) 2D representations.CC BY · PubMed Central
Figure 8 Illustration of some Pareto fronts when minimizing two objectives (misclassification and classification runtime) according to the obtained results in the waist.
Figure 8 Illustration of some Pareto fronts when minimizing two objectives (misclassification and classification runtime) according to the obtained results in the waist.CC BY · PubMed Central
Figure 9 (a) Overall view of the non-dominated classifiers (classifier ID) and their power in providing high recognition accuracy (b) recognition system capabilities for diverse overlap values.
Figure 9 (a) Overall view of the non-dominated classifiers (classifier ID) and their power in providing high recognition accuracy (b) recognition system capabilities for diverse overlap values.CC BY · PubMed Central
Figure 10 Analysis of number of classifiers, which provide good results (90%–99%) by taking different overlap sizes into account for different positions.
Figure 10 Analysis of number of classifiers, which provide good results (90%–99%) by taking different overlap sizes into account for different positions.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Research works printed but not linked: 6

  1. Ugulino, W., Cardador, D., Vega, K., Velloso, E., Milidiu, R., and Fuks, H. (2012). Advances in Artificial Intelligence—SBIA 2012, Proceedings of the 21st Brazilian Symposium on Artificial Intelligence, Curitiba, Brazil, 20–25 October 2012, Springer.
  2. Peterek, T., Penhaker, M., Gajdoš, P., and Dohnálek, P. (2014). Innovations in Bio-Inspired Computing and Applications, Springer.
  3. Balaprakash, P., Tiwari, A., Wild, S., Jarvis, S.A., Wright, S.A., and Hammond, S.D. (2014). International Workshop on Performance Modeling, Benchmarking and Simulation of High Performance Computer Systems, Springer Lecture Notes in Computer Science.
  4. Theodoridis, S., and Koutroumbas, K. (2008). Pattern Recognition, Elsevier/Academic Press. [4th ed.].
  5. Bishop, C.M. (2006). Pattern Recognition and Machine Learning, Springer.
  6. Vernon, S.S. (2010). Intelligent and Biosensors, InTech. Chapter 10.

Cited by

See all 224

Metadata

Authors
Janidarmian, M., Roshan Fekr, A., Radecka, K., & Zilic, Z.
Affiliations
  • McGill University (CA)
  • Electrical and Computer Engineering Department, McGill University, Montréal, QC H3A 0E9, Canada
Corresponding author
Janidarmian, Majid
Venue
Sensors
Publisher
MDPI AG
Published
2017-03-07
Volume
17
Issue
3
Pages
529
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2593796416
Cited by
217
References
59
Citations by year
2026: 8 · 2025: 13 · 2024: 22 · 2023: 21 · 2022: 25 · 2021: 35 · 2020: 44 · 2019: 27 · 2018: 18 · 2017: 4
FWCI
10.56
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
Keywords
human activity recognition, wearable accelerometers, activity dataset, feature representation, classifier comparison, principal component analysis, sensor placement
MeSH terms
Acceleration, Machine Learning, Wearable Electronic Devices, Humans, Human Activities, Motion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comprehensive Analysis on Wearable Acceleration Sensors in Human Activity Recognition. https://app.cochat.ai/papers/10.3390/s17030529
The paper
Janidarmian, M., Roshan Fekr, A., Radecka, K., & Zilic, Z. (2017). A Comprehensive Analysis on Wearable Acceleration Sensors in Human Activity Recognition. Sensors. https://doi.org/10.3390/s17030529

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.