The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors
Open accessAbstract
Specialized myoelectric sensors have been used in prosthetics for decades, but, with recent advancements in wearable sensors, wireless communication and embedded technologies, wearable electromyographic (EMG) armbands are now commercially available for the general public. Due to physical, processing, and cost constraints, however, these armbands typically sample EMG signals at a lower frequency (e.g., 200 Hz for the Myo armband) than their clinical counterparts. It remains unclear whether existing EMG feature extraction methods, which largely evolved based on EMG signals sampled at 1000 Hz or above, are still effective for use with these emerging lower-bandwidth systems. In this study, the effects of sampling rate (low: 200 Hz vs. high: 1000 Hz) on the classification of hand and finger movements were evaluated for twenty-six different individual features and eight sets of multiple features using a variety of datasets comprised of both able-bodied and amputee subjects. The results show that, on average, classification accuracies drop significantly ( p < 0.05) from 2% to 56% depending on the evaluated features when using the lower sampling rate, and especially for transradial amputee subjects. Importantly, for these subjects, no number of existing features can be combined to compensate for this loss in higher-frequency content. From these results, we identify two new sets of recommended EMG features (along with a novel feature, L-scale) that provide better performance for these emerging low-sampling rate systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
New Effect Size Rules of Thumb
Sawilowsky, S. S. (2009) · Journal of Modern Applied Statistical Methods · doi:10.22237/jmasm/1257035100 · Cited by 3,254
L-Moments: Analysis and Estimation of Distributions Using Linear Combinations of Order Statistics
Hosking, J. R. M. (1990) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1990.tb01775.x · Cited by 3,146
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Self-citationMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Self-citationThe Appropriate Use of Approximate Entropy and Sample Entropy with Short Data Sets
Yentes, J. M., Hunt, N., Schmid, K. K., Kaipust, J. P., McGrath, D., & Stergiou, N. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0668-3 · Cited by 893
Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829
EMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
Self-citationHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Study of stability of time-domain features for electromyographic pattern recognition
Tkach, D., Huang, H., & Kuiken, T. A. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-21 · Cited by 582
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Comparison of six electromyography acquisition setups on hand movement classification tasks
Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186132 · Cited by 421
Evaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Al-Timemy, A. H., Khushaba, R. N., Bugmann, G., & Escudero, J. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2445634 · Cited by 336
Enabling always-available input with muscle-computer interfaces
Saponas, T. S., Tan, D. S., Morris, D., Balakrishnan, R., Turner, J., & Landay, J. A. (2009) · Proceedings of the 22nd annual ACM symposium on User interface software and technology · doi:10.1145/1622176.1622208 · Cited by 328
Khushaba, R. N., Takruri, M., Miro, J. V., & Kodagoda, S. (2014) · Neural Networks · doi:10.1016/j.neunet.2014.03.010 · Cited by 204
Combined influence of forearm orientation and muscular contraction on EMG pattern recognition
Khushaba, R. N., Al-Timemy, A., Kodagoda, S., & Nazarpour, K. (2016) · Expert Systems with Applications · doi:10.1016/j.eswa.2016.05.031 · Cited by 196
Samuel, O. W., Zhou, H., Li, X., Wang, H., Zhang, H., Sangaiah, A. K., & Li, G. (2018) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2017.04.003 · Cited by 193
Huang, H., Zhou, P., Li, G., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910282 · Cited by 187
Feature extraction of the first difference of EMG time series for EMG pattern recognition
Phinyomark, A., Quaine, F., Charbonnier, S., Servière, C., Tarpin-Bernard, F., & Laurillau, Y. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.06.013 · Cited by 166
Self-citationBunderson, N. E., & Kuiken, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2182525 · Cited by 124
Recognition of Electromyographic Signals Using Cascaded Kernel Learning Machine
Liu, Y., Huang, H., & Weng, C.-H. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897253 · Cited by 121
Fractal analysis features for weak and single-channel upper-limb EMG signals
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.03.039 · Cited by 115
Self-citationEvaluation of the Myo armband for the classification of hand motions
Guerra, I. M., Hansen, B. W., Grabow, C., Smedegaard, E. J. L., Skogberg, N. B., Uth, X. J., Bruhn, A., Geng, B., & Kamavuako, E. N. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009414 · Cited by 110
Li, G., Li, Y., Yu, L., & Geng, Y. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0265-x · Cited by 109
Evaluating Sign Language Recognition Using the Myo Armband
Abreu, J. G., Teixeira, J. M., Figueiredo, L. S., & Teichrieb, V. (2016) · Symposium on Virtual and Augmented Reality (SVR) · doi:10.1109/svr.2016.21 · Cited by 97
Application of Higher Order Statistics to Surface Electromyogram Signal Classification
Nazarpour, K., Sharafat, A. R., & Firoozabadi, M. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.894829 · Cited by 91
Probability Density Functions of Stationary Surface EMG Signals in Noisy Environments
Thongpanja, S., Phinyomark, A., Quaine, F., Laurillau, Y., Limsakul, C., & Phukpattaranont, P. (2016) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2016.2534378 · Cited by 82
Self-citationNavigating features: a topologically informed chart of electromyographic features space
Phinyomark, A., Khushaba, R. N., Ibáñez‐Marcelo, E., Patania, A., Scheme, E., & Petri, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0734 · Cited by 81
Self-citationPhinyomark, A., Limsakul, C., & Phukpattaranont, P. (2011) · IETE Technical Review · doi:10.4103/0256-4602.83552 · Cited by 76
Self-citationComparison of five time series EMG features extractions using Myo Armband
Arief, Z., Sulistijono, I. A., & Ardiansyah, R. A. (2015) · International Electronics Symposium (IES) · doi:10.1109/elecsym.2015.7380805 · Cited by 72
A feature extraction issue for myoelectric control based on wearable EMG sensors
Phinyomark, A., & Scheme, E. (2018) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2018.8336753 · Cited by 59
Self-citationDesigning Game-Based Myoelectric Prosthesis Training
Tabor, A., Bateman, S., Scheme, E., Flatla, D. R., & Gerling, K. (2017) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3025453.3025676 · Cited by 51
Self-citationRadmand, A., Scheme, E., & Englehart, K. B. (2014) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000041 · Cited by 49
Self-citationImproving myoelectric pattern recognition positional robustness using advanced training protocols
Scheme, E., Biron, K., & Englehart, K. B. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091196 · Cited by 48
Self-citationPhinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Fluctuation and Noise Letters · doi:10.1142/s0219477512500289 · Cited by 48
Self-citationEnabling Low-Power, Multi-Modal Neural Interfaces Through a Common, Low-Bandwidth Feature Space
Irwin, Z. T., Thompson, D. E., Schroeder, K. E., Tat, D. M., Hassani, A., Bullard, A. J., Woo, S. L., Urbanchek, M. G., Sachs, A. J., Cederna, P. S., et al. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2501752 · Cited by 45
EMG feature extraction for tolerance of white Gaussian noise
Phinyomark, A., Limsakul, C., & Phukpattaranont, P. (2008) · Cited by 44
Self-citationKamavuako, E. N., Scheme, E., & Englehart, K. B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046011 · Cited by 43
Self-citationA Bus-Based Smart Myoelectric Electrode/Amplifier—System Requirements
Wilson, A. W., Losier, Y. G., Parker, P. A., & Lovely, D. F. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2159316 · Cited by 35
Exploring the relation between EMG sampling frequency and hand motion recognition accuracy
Chen, H., Zhang, Y., Zhang, Z. D., Fang, Y., Liu, H., & Yao, C. (2017) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2017.8122765 · Cited by 31
Li, Y., Chen, X. '., Zhang, X., & Zhou, P. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.01.005 · Cited by 26
Amirabdollahian, F., & Walters, M. L. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009231 · Cited by 25
EMG pattern recognition using Support Vector Machines classifier for myoelectric control purposes
León, M., Gutiérrez, J. M., Leija, L., & Muñoz, R. (2011) · Pan American Health Care Exchanges · doi:10.1109/pahce.2011.5871873 · Cited by 24
Phinyomark, A., Quaine, F., & Laurillau, Y. (2014) · Advances in medical technologies and clinical practice book series · doi:10.4018/978-1-4666-6090-8.ch015 · Cited by 16
Self-citationMyoelectric Prostheses and Targeted Reinnervation
Hargrove, L. J., Scheme, E., & Englehart, K. B. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch15 · Cited by 4
Self-citation
Cited by
A review of feature selection methods in medical applications
Remeseiro, B., & Bolon-Canedo, V. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103375 · Cited by 804
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
Self-citationJaramillo-Yánez, A., Benalcázar, M. E., & Mena-Maldonado, E. (2020) · Sensors · doi:10.3390/s20092467 · Cited by 259
Bangaru, S. S., Wang, C., & Aghazadeh, F. (2020) · Sensors · doi:10.3390/s20185264 · Cited by 58
Metadata
- Authors
- Phinyomark, A., N. Khushaba, R., & Scheme, E.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-05-18
- Volume
- 18
- Issue
- 5
- Pages
- 1615
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2804301333
- Cited by
- 352
- References
- 50
- FWCI
- 12.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.