Smart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this paper, a first approach to the design of a portable device for non-contact monitoring of respiratory rate by capacitive sensing is presented. The sensing system is integrated into a smart vest for an untethered, low-cost and comfortable breathing monitoring of Chronic Obstructive Pulmonary Disease (COPD) patients during the rest period between respiratory rehabilitation exercises at home. To provide an extensible solution to the remote monitoring using this sensor and other devices, the design and preliminary development of an e-Health platform based on the Internet of Medical Things (IoMT) paradigm is also presented. In order to validate the proposed solution, two quasi-experimental studies have been developed, comparing the estimations with respect to the golden standard. In a first study with healthy subjects, the mean value of the respiratory rate error, the standard deviation of the error and the correlation coefficient were 0.01 breaths per minute (bpm), 0.97 bpm and 0.995 (p < 0.00001), respectively. In a second study with COPD patients, the values were −0.14 bpm, 0.28 bpm and 0.9988 (p < 0.0000001), respectively. The results for the rest period show the technical and functional feasibility of the prototype and serve as a preliminary validation of the device for respiratory rate monitoring of patients with COPD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rahmani, A. M., Gia, T. N., Negash, B., Anzanpour, A., Azimi, I., Jiang, M., & Liljeberg, P. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2017.02.014 · Cited by 1,198
Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients.
Fieselmann, J. F., Hendryx, M. S., Helms, C. M., & Wakefield, D. S. (1993) · Journal of General Internal Medicine · doi:10.1007/bf02600071 · Cited by 399 · cited 1×
“The respiratory rate has been used to anticipate dangerous events such as cardiac arrest [13], to classify patients in intensive care units [14] and to predict complications or exacerbations in patients with cardiopulmonary diseases [15].”
Baig, M. M., GholamHosseini, H., Moqeem, A. A., Mirza, F., & Lindén, M. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0760-1 · Cited by 351 · cited 1×
“In general, there are recent works presenting a diversity of wearable devices for the collection of biomedical parameters in IoT platforms, including posture [45], respiratory rate [46], blood pressure [47], blood glucose level [48] and more [49].”
BackgroundChest wall volumes during inspiratory loaded breathing in COPD patients
Coutinho Myrrha, M. A., Vieira, D. S. R., Moraes, K. S., Lage, S. M., Parreira, V. F., & Britto, R. R. (2013) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2013.04.017 · Cited by 30 · cited 2×
“Respiratory monitoring during two minutes at rest has been proposed as a method to evaluate respiratory rehabilitation efficacy [65] and the improvements in the breathing skills [66,67].”
MethodCiudin, A., Salvador, R., Budoy, A., Ciudin, A., Spinu, C., Diaconu, M. G., Constantin, V., Sánchez, J., Nicolau, C., & Alcaraz, A. (2014) · Endocrinología y Nutrición · doi:10.1016/j.endonu.2013.10.004 · Cited by 25
Cited by
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Wearables and the Internet of Things (IoT), Applications, Opportunities, and Challenges: A Survey
John Dian, F., Vahidnia, R., & Rahmati, A. (2020) · IEEE Access · doi:10.1109/access.2020.2986329 · Cited by 386
A comprehensive survey on multimodal medical signals fusion for smart healthcare systems
Muhammad, G., Alshehri, F., Karray, F., Saddik, A. E., Alsulaiman, M., & Falk, T. H. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.06.007 · Cited by 287
Ahmed, S. F., Alam, M. S. B., Afrin, S., Rafa, S. J., Rafa, N., & Gandomi, A. H. (2024) · Information Fusion · doi:10.1016/j.inffus.2023.102060 · Cited by 258
Metadata
- Authors
- Naranjo-Hernández, D., Talaminos-Barroso, A., Reina-Tosina, J., Roa, L. M., Barbarov-Rostan, G., Cejudo-Ramos, P., Márquez-Martín, E., & Ortega-Ruiz, F.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2018-07-03
- Volume
- 18
- Issue
- 7
- Pages
- 2144
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2809767447
- Cited by
- 89
- References
- 5
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Smart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing. https://app.cochat.ai/papers/10.3390/s18072144
- The paper
- Naranjo-Hernández, D., Talaminos-Barroso, A., Reina-Tosina, J., Roa, L. M., Barbarov-Rostan, G., Cejudo-Ramos, P., Márquez-Martín, E., & Ortega-Ruiz, F. (2018). Smart Vest for Respiratory Rate Monitoring of COPD Patients Based on Non-Contact Capacitive Sensing. Sensors. https://doi.org/10.3390/s18072144
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.