CoChat

Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges

Open access

The DOI matches its Crossref record; 146 of the 150 references it cites were found in a registry or an index.

Abstract

The world’s population is aging: the expansion of the older adult population with multiple physical and health issues is now a huge socio-economic concern worldwide. Among these issues, the loss of mobility among older adults due to musculoskeletal disorders is especially serious as it has severe social, mental and physical consequences. Human body joint monitoring and early diagnosis of these disorders will be a strong and effective solution to this problem. A smart joint monitoring system can identify and record important musculoskeletal-related parameters. Such devices can be utilized for continuous monitoring of joint movements during the normal daily activities of older adults and the healing process of joints (hips, knees or ankles) during the post-surgery period. A viable monitoring system can be developed by combining miniaturized, durable, low-cost and compact sensors with the advanced communication technologies and data processing techniques. In this study, we have presented and compared different joint monitoring methods and sensing technologies recently reported. A discussion on sensors’ data processing, interpretation, and analysis techniques is also presented. Finally, current research focus, as well as future prospects and development challenges in joint monitoring systems are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s19112629

Cites

146 of 146 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (a) Synovial joints; (b) Types of synovial joints. Image source: https://opentextbc.ca/anatomyandphysiology/chapter/9-4-synovial-joints/under a Creative Commons Attribution 4.0 International License.
Figure 1 (a) Synovial joints; (b) Types of synovial joints. Image source: https://opentextbc.ca/anatomyandphysiology/chapter/9-4-synovial-joints/under a Creative Commons Attribution 4.0 International License.CC BY · PubMed Central
Figure 2 Proportion of total global years lived with disability (YLDs) in older age (50 years and more) groups attributable to each major set of health conditions in developing countries (a) 50–69 years; (b) 70+ years; and developed countries (c) 50–69 years; (d) 70+ years. Source: The Global Burden of Disease Study 2010 (GBD 2010).
Figure 2 Proportion of total global years lived with disability (YLDs) in older age (50 years and more) groups attributable to each major set of health conditions in developing countries (a) 50–69 years; (b) 70+ years; and developed countries (c) 50–69 years; (d) 70+ years. Source: The Global Burden of Disease Study 2010 (GBD 2010).CC BY · PubMed Central
Figure 3 Joint monitoring sensor technologies and monitored parameters.
Figure 3 Joint monitoring sensor technologies and monitored parameters.CC BY · PubMed Central
Figure 4 Different types of human body joints’ movements.
Figure 4 Different types of human body joints’ movements.CC BY · PubMed Central
Figure 5 (a) Optical fiber configuration and working principle; (b) construction and operation method of the fiber-optic curvature sensor with a “teeth-like” sensitive zone; (c) flexible optical fiber sensors (OFS)-based joint monitoring system configuration.
Figure 5 (a) Optical fiber configuration and working principle; (b) construction and operation method of the fiber-optic curvature sensor with a “teeth-like” sensitive zone; (c) flexible optical fiber sensors (OFS)-based joint monitoring system configuration.CC BY · PubMed Central
Figure 6 Components and working principle of optical-based goniometer system. The system was composed of five components: (1) a semiconductor laser as light source, (2) a Si p–i–n photodiode as photo detector, (3,4) two linear polarizers as polarizing and analyzing filters, and (5) a single-mode optical fiber as stress-induced birefringence polarization controller (SIBPC).
Figure 6 Components and working principle of optical-based goniometer system. The system was composed of five components: (1) a semiconductor laser as light source, (2) a Si p–i–n photodiode as photo detector, (3,4) two linear polarizers as polarizing and analyzing filters, and (5) a single-mode optical fiber as stress-induced birefringence polarization controller (SIBPC).CC BY · PubMed Central
Figure 7 (a) Sensing setup of optical-based goniometer system for human elbow joint measurement; (b) operation method of the system.
Figure 7 (a) Sensing setup of optical-based goniometer system for human elbow joint measurement; (b) operation method of the system.CC BY · PubMed Central
Figure 8 Block diagram of imaging-based human skeletal tracking.
Figure 8 Block diagram of imaging-based human skeletal tracking.CC BY · PubMed Central
Figure 9 (a) Distributed camera networks for skeletal tracking; (b) Microsoft Kinect sensor system.
Figure 9 (a) Distributed camera networks for skeletal tracking; (b) Microsoft Kinect sensor system.CC BY · PubMed Central
Figure 10 Schematic design of conductive wire sensor-based wearable joint monitoring device.
Figure 10 Schematic design of conductive wire sensor-based wearable joint monitoring device.CC BY · PubMed Central
Figure 11 Inertial measurement unit (IMU) sensors’ orientation and position for knee angle measurement.
Figure 11 Inertial measurement unit (IMU) sensors’ orientation and position for knee angle measurement.CC BY · PubMed Central
Figure 12 Process flow of joint angle measurement with IMU devices.
Figure 12 Process flow of joint angle measurement with IMU devices.CC BY · PubMed Central
Figure 13 A simplified block diagram of sensor fusion methods.
Figure 13 A simplified block diagram of sensor fusion methods.CC BY · PubMed Central
Figure 14 A generic flow diagram of a joint monitoring system.
Figure 14 A generic flow diagram of a joint monitoring system.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 6

  1. OpenStax (2019, June 06). Anatomy and Physiology: Chapter 9.4 Synovial Joints. Available online: http://cnx.org/contents/14fb4ad7-39a1-4eee-ab6e-3ef2482e3e22@8.24.
  2. Seel, T., and Schauer, T. (2013, January 14–15). IMU-based joint angle measurement made practical. Proceedings of the 4th European Conference on Technically Assisted Rehabilitation, Berlin, Germany. · DOI · Paper page
  3. Bergmann, T., and Peterson, D. (2010). Chiropractic Technique: Chapter 2 Joint Anatomy and Basic Biomechanics. Chiropractic Technique, Elsevier/Mosby.
  4. Slightam, J.E. (2016). Modeling and Simulation of Biologically Inspired 3D-Printed Fluid Power Robotic System Architectures. [Ph.D. Thesis, Milwaukee School of Engineering].
  5. Rakheja, 2012, Knee Deformity Recognition and Deform Angle Measurement, Int. J. Appl. Inf. Syst., 3, 47
  6. Yousefpour, 2014, A comparative study on sentiment analysis, Adv. Environ. Biol., 8, 53

Cited by

See all 187

Metadata

Authors
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J.
Affiliations
  • McMaster University (CA)
  • St. Joseph’s Healthcare Hamilton (CA)
Corresponding author
Deen, M. Jamal
Venue
Sensors
Publisher
MDPI AG
Published
2019-06-10
Volume
19
Issue
11
Pages
2629
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2948471521
Cited by
187
References
150
Citations by year
2026: 14 · 2025: 27 · 2024: 41 · 2023: 28 · 2022: 24 · 2021: 25 · 2020: 25 · 2019: 3
FWCI
2.04
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Canada Research Chairs (xx)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
joint monitoring, musculoskeletal disorders, older adults, mobility loss, wearable sensors, intelligent monitoring system, sensor data processing, early diagnosis, postoperative rehabilitation, population aging
MeSH terms
Wearable Electronic Devices, Aged, Biomechanical Phenomena, Female, Humans, Joints, Monitoring, Physiologic, Movement, Range of Motion, Articular, Human Body

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.