Abstract

A gait event is a crucial step towards the effective assessment and rehabilitation of motor dysfunctions. However, for the data acquisition of a three-dimensional motion capture (3D Mo-Cap) system, the high cost of setups, such as the high standard laboratory environment, limits widespread clinical application. Inertial sensors are increasingly being used to recognize and classify physical activities in a variety of applications. Inertial sensors are now sufficiently small in size and light in weight to be part of a body sensor network for the collection of human gait data. The acceleration signal has found important applications in human gait recognition. In this paper, using the experimental data from the heel and toe, first the wavelet method was used to remove noise from the acceleration signal, then, based on the threshold of comprehensive change rate of the acceleration signal, the signal was primarily segmented. Subsequently, the vertical acceleration signals, from heel and toe, were integrated twice, to compute their respective vertical displacement. Four gait events were determined in the segmented signal, based on the characteristics of the vertical displacement of heel and toe. The results indicated that the gait events were consistent with the synchronous record of the motion capture system. The method has achieved gait event subdivision, while it has also ensured the accuracy of the defined gait events. The work acts as a valuable reference, to further study gait recognition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s19245499

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Hardware module and acquisition process diagram of experimental acquisition equipment. (a) The position of heel and toe in lower extremity; (b) data acquisition process; (c) equipment for acceleration signal.
Figure 1 Hardware module and acquisition process diagram of experimental acquisition equipment. (a) The position of heel and toe in lower extremity; (b) data acquisition process; (c) equipment for acceleration signal.CC BY · PubMed Central
Figure 2 Contrast between the heel vertical acceleration signal states, before and after noise elimination. (a) Raw heel acceleration signal; (b) noise-free heel acceleration signal.
Figure 2 Contrast between the heel vertical acceleration signal states, before and after noise elimination. (a) Raw heel acceleration signal; (b) noise-free heel acceleration signal.CC BY · PubMed Central
Figure 3 Contrast between the toe vertical acceleration signal states, before and after noise elimination. (a) Raw toe acceleration signal; (b) noise-free toe acceleration signal.
Figure 3 Contrast between the toe vertical acceleration signal states, before and after noise elimination. (a) Raw toe acceleration signal; (b) noise-free toe acceleration signal.CC BY · PubMed Central
Figure 4 The schematic diagram of lower limb movement throughout the gait cycle.
Figure 4 The schematic diagram of lower limb movement throughout the gait cycle.CC BY · PubMed Central
Figure 5 Preliminary segmentation results of the heel and toe signals. (a) Preliminary segmentation result of the heel signals; (b) preliminary segmentation results of the toe signals.
Figure 5 Preliminary segmentation results of the heel and toe signals. (a) Preliminary segmentation result of the heel signals; (b) preliminary segmentation results of the toe signals.CC BY · PubMed Central
Figure 6 Displacement change of the heel, without filtering.
Figure 6 Displacement change of the heel, without filtering.CC BY · PubMed Central
Figure 7 Displacement change of the toe, without filtering.
Figure 7 Displacement change of the toe, without filtering.CC BY · PubMed Central
Figure 8 Wavelet decomposition of heel and toe displacement. (a) Wavelet decomposition of the heel displacement; (b) wavelet decomposition of the toe displacement.
Figure 8 Wavelet decomposition of heel and toe displacement. (a) Wavelet decomposition of the heel displacement; (b) wavelet decomposition of the toe displacement.CC BY · PubMed Central
Figure 9 Displacement change of the heel with filtering.
Figure 9 Displacement change of the heel with filtering.CC BY · PubMed Central
Figure 10 Displacement change of the toe without filtering.
Figure 10 Displacement change of the toe without filtering.CC BY · PubMed Central
Figure 11 Determination of the heel event.
Figure 11 Determination of the heel event.CC BY · PubMed Central
Figure 12 Determination of the toe event.
Figure 12 Determination of the toe event.CC BY · PubMed Central
Figure 13 The statistical analysis of error. (a) The true error of heel strike (HS) event; (b) the true error of toe strike (TS) event; (c) the true error of heel off (HO) event; (d) the true error of toe off (TO) event.
Figure 13 The statistical analysis of error. (a) The true error of heel strike (HS) event; (b) the true error of toe strike (TS) event; (c) the true error of heel off (HO) event; (d) the true error of toe off (TO) event.CC BY · PubMed Central
Figure 14 The consistency test of the Bland–Altman graph. (a) The Bland–Altman of HS event; (b) the Bland–Altman of TO event; (c) the Bland–Altman of HO event; (d) the Bland–Altman of TO event. The horizontal axis is the mean value of the results of theoretical analysis and the contrast results, and the vertical axis is the difference value of the results of theoretical analysis and the contrast results.
Figure 14 The consistency test of the Bland–Altman graph. (a) The Bland–Altman of HS event; (b) the Bland–Altman of TO event; (c) the Bland–Altman of HO event; (d) the Bland–Altman of TO event. The horizontal axis is the mean value of the results of theoretical analysis and the contrast results, and the vertical axis is the difference value of the results of theoretical analysis and the contrast results.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 3

  1. Gao, 2015, Gait recogIlition for lower extremity electromyographic signals based on PSO-SVM method, J. Electron. Inf. Technol., 37, 1154
  2. Chen, 2016, Human gait events fast recognition method via surface electromyography, China Mech. Eng., 27, 911
  3. Luo, 2009, Hermite interpolation-based wavelet transform modulus maxima reconstruction algorithm’s application to EMG de-noising, J. Electron. Inf. Technol., 31, 857

Cited by

See all 21

Metadata

Authors
Mei, C., Gao, F., & Li, Y.
Affiliations
Hangzhou Dianzi University (CN)
Corresponding author
Gao, Farong
Venue
Sensors
Publisher
MDPI AG
Published
2019-12-12
Volume
19
Issue
24
Pages
5499
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2996526055
Cited by
16
References
46
Citations by year
2026: 1 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 4
FWCI
0.97
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
National Natural Science Foundation of China (U1509203)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
Keywords
gait event detection, acceleration sensors, inertial sensors, wavelet denoising, signal segmentation, vertical displacement, gait recognition, wireless body area networks

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.