Active Magnetic-Field Stabilization with Atomic Magnetometer
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
A magnetically-quiet environment is important for detecting faint magnetic-field signals or nonmagnetic spin-dependent interactions. Passive magnetic shielding using layers of large magnetic-permeability materials is widely used to reduce the magnetic-field noise. The magnetic-field noise can also be actively monitored with magnetometers and then compensated, acting as a complementary method to the passive shielding. We present here a general model to quantitatively depict and optimize the performance of active magnetic-field stabilization and experimentally verify our model using optically-pumped atomic magnetometers. We experimentally demonstrate a magnetic-field noise rejection ratio of larger than ∼800 at low frequencies and an environment with a magnetic-field noise floor of ∼40 fT/Hz1/2 in unshielded Earth’s field. The proposed model provides a general guidance on analyzing and improving the performance of active magnetic-field stabilization with magnetometers. This work offers the possibility of sensitive detections of magnetic-field signals in a variety of unshielded natural environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 Optimization of the active magnetic-field stabilization system. (a) Amplitude–frequency responses of the feedback controller and the magnetometer. (b) Phase–frequency responses of the feedback controller and the magnetometer. (c) The calculated noise rejection ratios under different parameter settings of the feedback controller. The dashed black lines in (a,b) are the calculated amplitude- and phase- frequency responses of the magnetometer. The solid lines in (a,b) are the calculated amplitude- and phase- frequency responses of −1/[FB(s)×MG(s)]. Different colors of the lines indicate different parameters of the feedback controllers, i.e., orange (blue) for a PID module with a small (big) integration coefficient KI, and green for a PI²D module.](https://figures.cochat.ai/paper-figures/636fb654b51e44e791413fe9287859d8/active-magnetic-field-stabilization-with-atomic-magnetometer-figure-2.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“If we want to realize a high CMRR in a low-frequency band for MCG signals, then the OPMs should have wide bandwidths, which usually benefit the consistency of OPMs (51).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [51]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Improved Experimental Limit on the Electric Dipole Moment of the Neutron
Baker, C. A., Doyle, D. D., Geltenbort, P., Green, K., van der Grinten, M. G. D., Harris, P. G., Iaydjiev, P., Ivanov, S. N., May, D. J. R., Pendlebury, J. M., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.131801 · Cited by 1,311
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Optically Driven Spin Precession
Bell, W. E., & Bloom, A. L. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.280 · Cited by 366
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Developments in alkali -metal atomic magnetometry
Seltzer, S. J. (2008) · Cited by 308
New Limit on Lorentz- andCPT-Violating Neutron Spin Interactions
Brown, J. M., Smullin, S. J., Kornack, T. W., & Romalis, M. V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.151604 · Cited by 295
Light Shifts in the Alkali Atoms
Mathur, B. S., Tang, H., & Happer, W. (1968) · Physical Review · doi:10.1103/physrev.171.11 · Cited by 286 · cited 1×
“Such a phenomenon is quite interesting since it proves that, with the active magnetic-field stabilization system, some of the magnetic-like-noise of the magnetometer for field stabilization, for example, the noise originating from the vector light shift [51], are taken as the magnetic-field noise and is actively stabi…”
Background(2013) · doi:10.1017/cbo9780511846380 · Cited by 286
Research works printed but not linked: 3
- Bork, J., Hahlbohm, H., Klein, R., and Schnabel, A. (2000, January 13–17). The 8-layered magnetically shielded room of the PTB: Design and construction. Proceedings of the 12th International Conference on Biomagnetism (Biomag2000), Espoo, Finland.
- Keviczky, L., Bars, R., Hetthéssy, J., and Bányász, C. (2019). Control Engineering, Springer. · DOI
- Keviczky, L., Bars, R., Hetthéssy, J., and Bányász, C. (2019). Proofs and derivations (by chapters). Control Engineering, Springer. · DOI
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“If we want to realize a high CMRR in a low-frequency band for MCG signals, then the OPMs should have wide bandwidths, which usually benefit the consistency of OPMs ( 51 ).”
Self-citationSensitive magnetometry in challenging environments
Fu, K. C., Iwata, G. Z., Wickenbrock, A., & Budker, D. (2020) · AVS Quantum Science · doi:10.1116/5.0025186 · Cited by 132
Two-photon electromagnetic induction imaging with an atomic magnetometer
Maddox, B., & Renzoni, F. (2023) · Applied Physics Letters · doi:10.1063/5.0147291 · Cited by 19
VCSEL frequency stabilization for optically pumped magnetometers
Yan, Y., Liu, G., Lin, H., Yin, K., Wang, K., & Lu, J. (2021) · Chinese Optics Letters · doi:10.3788/col202119.121407 · Cited by 16
Tian, P., Le, Y., Zhang, H., & Zheng, S. (2025) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2025.3538134 · Cited by 14
Dual-Species All-Optical Magnetometer Based on a Cs-K Hybrid Vapor Cell
Ding, Y., Xiao, W., Zhao, Y., Wu, T., Peng, X., & Guo, H. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.034066 · Cited by 15
Self-citationA high performance active noise control system for magnetic fields
Pyragius, T., & Jensen, K. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062650 · Cited by 19
Active stabilization of terrestrial magnetic field with potassium atomic magnetometer
Ding, Y., Zhang, R., Zheng, J., Chen, J., Peng, X., Wu, T., & Guo, H. M. (2022) · Review of Scientific Instruments · doi:10.1063/5.0073636 · Cited by 14
Self-citationFrequency Response of Optically Pumped Magnetometer with Nonlinear Zeeman Effect
Zhang, R., Wu, T., Chen, J., Peng, X., & Guo, H. M. (2020) · Applied Sciences · doi:10.3390/app10207031 · Cited by 14
“As closed-loop magnetic-noise-compensation setups require adequate knowledge of the system response, our work can also help to improve the performance of the active magnetic-field stabilization operated in the Earth’s field [29,37] which is attractive for ultralow-field nuclear magnetic resonance [7] and for recording…”
BackgroundSelf-citationSimple and active magnetic-field stabilization for cold atom experiments
Duan, Z.-X., Wu, W.-T., Lin, Y., & Yang, S.-J. (2022) · Review of Scientific Instruments · doi:10.1063/5.0119778 · Cited by 13
Li, S., Dai, P., Liu, J., Xu, Z., & Chida, K. (2022) · Optical Materials Express · doi:10.1364/ome.462911 · Cited by 14
Langevin approach to magnetic-field-gradient-induced spin relaxation in a coated cell
Zheng, J., Xiao, W., Li, S., Peng, X., Wu, T., & Guo, H. M. (2024) · Physical Review A · doi:10.1103/physreva.109.022803 · Cited by 10
Self-citationIn-situ magnetic fields monitoring and compensation for zero-field atomic magnetometers
Yan, Y., Zhang, K., Liu, Z., Liu, Z., Li, X., Zhou, Y., & Lu, J. (2024) · Measurement · doi:10.1016/j.measurement.2024.115410 · Cited by 11
Compensation of complex environmental magnetic field disturbances for biomagnetic field measurements
Wang, H., Li, H., Sun, J., Liu, X., & Liu, X. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/adafd4 · Cited by 9
“Zhang et al [11] devised a PI 2 D control module to enhance the disturbance rejection ratio.”
Unambiguous measurement in an unshielded microscale magnetometer with sensitivity below 1 pT / Hz
Taylor, H. A. M., Bounds, C. C., Tritt, A., & Turner, L. D. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.024047 · Cited by 11
MRA-TESO-Based High-Precision Active Magnetic Compensation Method
Jin, Y., Cui, P., Zhang, H., Li, Y., & Yang, Z. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2025.3592993 · Cited by 8
“However, this modification can adversely a ff ect system stability [22].”
Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer
Lu, F., Wang, S., Xu, N., Li, B., Lu, J., & Han, B. (2022) · Photonics · doi:10.3390/photonics9110792 · Cited by 8
“However, the background magnetic fields are difficult to maintain at zero due to the magnetic field drift, which will lead to measurement error [12–14], as it also occurs in magnetometers of other principles, such as fluxgate and non-SERF atomic magnetometers [15,16].”
Indirect Zero-Field Nuclear Magnetic Resonance Spectroscopy
Buckenmaier, K., Neumann, R., Bullinger, F., Kempf, N., Povolni, P., Engelmann, J., Samlow, J., Hövener, J., Scheffler, K., Ortmeier, A., et al. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c00874 · Cited by 6
Quantum Sensing of Magnetic Fields Using Global Optimization Algorithms
Xiao, W., Ding, Y., Wu, T., Peng, X., & Guo, H. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024042 · Cited by 4
Self-citationCompensation of power line-induced magnetic interference in trapped-ion system
Han, H., Xie, Y., Zhang, M.-C., Qin, Q., Zhang, J., Su, W.-B., Zhan, T., Wu, C.-W., Chen, P., & Wu, W. (2023) · Applied Physics B · doi:10.1007/s00340-023-08106-8 · Cited by 6
Influence of Atomic Magnetometer’s Orientation on Its Frequency Response
Zhang, R. (2025) · Sensors · doi:10.3390/s25051364 · Cited by 3
“…closed-loop feedback processes, such as the closed-loop operation of the atomic magnetometer [55,64] or active magnetic field stabilization [65–67], this variable gain modifies the loop transfer function, altering key performance parameters including bandwidth, overshoot, and potentially…”
Self-citationAtomic Comagnetometer with a Closed-Loop Optically Aligned 87 Rb Dual-Frequency Oscillator
Wang, Z., Peng, X., Xiong, Z., Zheng, J., Luo, H., & Guo, H. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.024021 · Cited by 3
Self-citationWang, H., Chen, Y., Li, H., Wang, X., Meng, Y., Sun, J., & Liu, X. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3545058 · Cited by 3
“For MSRs where the static field does not meet the initial operating conditions of OPMs, it is first necessary to utilize coils to reduce the residual dc field [18], [19].”
Person-Sized Magnetoencephalography Systems with Optically Pumped Magnetometers
Schwindt, P. D. D., & Borna, A. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_7 · Cited by 4
Wu, H., Zhang, H., Tian, P., Zhao, X., & Zheng, S. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad74a7 · Cited by 2
Fiber-Coupled OPM in Purely Coil-Shielded Environment
Wu, T., Peng, X., Chen, J., & Guo, H. M. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_9 · Cited by 2
Self-citationPetrenko, M. V., Pazgalev, A. S., & Vershovskii, A. K. (2021) · IEEE Magnetics Letters · doi:10.1109/lmag.2021.3132851 · Cited by 2
Scalar Potassium Magnetometer Based On Amplitude Modulated Nonlinear Magneto-Optical Rotation
Ding, Y., Zhang, R., Zheng, J., Chen, J., Peng, X., Wu, T., & Guo, H. M. (2021) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs52194.2021.9604283
“More details about the integrated cesium magnetometer and the method of magnetic-field stabilization could be found in [5-6].”
MethodSelf-citationWang, H., Chen, Y., Li, H., Wang, X., Meng, Y., Sun, J., & Liu, X. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4844833
RCIESO based multi-source magnetic disturbance compensation method for magnetic shielding cylinder
Yao, J., Cui, P., Jin, Y., Gong, A., & Yangyang, C. (2026) · Measurement Science and Technology · doi:10.1088/1361-6501/ae5326
“For reasons of shielding effectiveness and cost, the current approach for achieving ultra-low magnetic field environments predominantly combines passive magnetic shielding with active magnetic compensation (AMC) [10, 11].”
Wang, X., Wang, Y., Yuan, J. M., Feng, C., Wang, W., Zhang, J., Shi, Y., & Liu, S. (2026) · Review of Scientific Instruments · doi:10.1063/5.0310496
Wen, R., 罗海军, Zhao, X., Zhao, T., & Yang, C. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.118306
Metadata
- Authors
- Zhang, R., Ding, Y., Yang, Y., Zheng, Z., Chen, J., Peng, X., Wu, T., & Guo, H.
- Affiliations
- National University of Defense Technology (CN)
- Peking University (CN)
- Corresponding author
- Guo, Hong
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-07-30
- Volume
- 20
- Issue
- 15
- Pages
- 4241
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7435849
- OpenAlex
- W3046171984
- Cited by
- 32
- References
- 58
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 5 · 2023: 6 · 2022: 6 · 2021: 4 · 2020: 2
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- the National Natural Science Foundation of China (No. 61571018, No. 61531003, No. 91436210)
- the National Science Fund for Distinguished Young Scholars of China (No. 61225003)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Keywords
- atomic magnetometer, magnetic noise, optically pumped magnetometers, magnetic shielding, magnetic field compensation, spin-dependent interactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.