Active Magnetic-Field Stabilization with Atomic Magnetometer
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
A magnetically-quiet environment is important for detecting faint magnetic-field signals or nonmagnetic spin-dependent interactions. Passive magnetic shielding using layers of large magnetic-permeability materials is widely used to reduce the magnetic-field noise. The magnetic-field noise can also be actively monitored with magnetometers and then compensated, acting as a complementary method to the passive shielding. We present here a general model to quantitatively depict and optimize the performance of active magnetic-field stabilization and experimentally verify our model using optically-pumped atomic magnetometers. We experimentally demonstrate a magnetic-field noise rejection ratio of larger than ∼800 at low frequencies and an environment with a magnetic-field noise floor of ∼40 fT/Hz1/2 in unshielded Earth’s field. The proposed model provides a general guidance on analyzing and improving the performance of active magnetic-field stabilization with magnetometers. This work offers the possibility of sensitive detections of magnetic-field signals in a variety of unshielded natural environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 Optimization of the active magnetic-field stabilization system. (a) Amplitude–frequency responses of the feedback controller and the magnetometer. (b) Phase–frequency responses of the feedback controller and the magnetometer. (c) The calculated noise rejection ratios under different parameter settings of the feedback controller. The dashed black lines in (a,b) are the calculated amplitude- and phase- frequency responses of the magnetometer. The solid lines in (a,b) are the calculated amplitude- and phase- frequency responses of −1/[FB(s)×MG(s)]. Different colors of the lines indicate different parameters of the feedback controllers, i.e., orange (blue) for a PID module with a small (big) integration coefficient KI, and green for a PI²D module.](https://figures.cochat.ai/paper-figures/636fb654b51e44e791413fe9287859d8/active-magnetic-field-stabilization-with-atomic-magnetometer-figure-2.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“If we want to realize a high CMRR in a low-frequency band for MCG signals, then the OPMs should have wide bandwidths, which usually benefit the consistency of OPMs (51).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [51]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Improved Experimental Limit on the Electric Dipole Moment of the Neutron
Baker, C. A., Doyle, D. D., Geltenbort, P., Green, K., van der Grinten, M. G. D., Harris, P. G., Iaydjiev, P., Ivanov, S. N., May, D. J. R., Pendlebury, J. M., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.131801 · Cited by 1,311
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Optically Driven Spin Precession
Bell, W. E., & Bloom, A. L. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.280 · Cited by 366
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Developments in alkali -metal atomic magnetometry
Seltzer, S. J. (2008) · Cited by 308
New Limit on Lorentz- andCPT-Violating Neutron Spin Interactions
Brown, J. M., Smullin, S. J., Kornack, T. W., & Romalis, M. V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.151604 · Cited by 295
Light Shifts in the Alkali Atoms
Mathur, B. S., Tang, H., & Happer, W. (1968) · Physical Review · doi:10.1103/physrev.171.11 · Cited by 286 · cited 1×
“Such a phenomenon is quite interesting since it proves that, with the active magnetic-field stabilization system, some of the magnetic-like-noise of the magnetometer for field stabilization, for example, the noise originating from the vector light shift [51], are taken as the magnetic-field noise and is actively stabi…”
Background(2013) · doi:10.1017/cbo9780511846380 · Cited by 286
Portable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257 · cited 1×
“Furthermore, a magnetic-field noise level of about tens of fT/Hz1/2 and a wide range of operational magnetic field covering Earth’s magnetic field is attractive for ultralow-field nuclear magnetic resonance [52,53] and for recording bio-magnetic signals from human brain activities [54,55].”
BackgroundHolmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
A low-noise ferrite magnetic shield
Kornack, T. W., Smullin, S. J., Lee, S.-K., & Romalis, M. V. (2007) · Applied Physics Letters · doi:10.1063/1.2737357 · Cited by 247 · cited 1×
“Passive magnetic shielding is widely used for suppressing the magnetic-field noise and is based on multi-layers of high magnetic permeability materials, such as mu-metal [19–24] and ferrite [25], or superconductors [26].”
BackgroundNew limits on spatial anisotropy from optically-pumped sup201 Hg and Hg 199
Lamoreaux, S. K., Jacobs, J. P., Heckel, B. R., Raab, F. J., & Fortson, E. N. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.3125 · Cited by 235
Atomic Electric Dipole Moment Measurement Using Spin Exchange Pumped Masers of129Xeand3He
Rosenberry, M. A., & Chupp, T. E. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.22 · Cited by 223
Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers
Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba8792 · Cited by 222 · cited 1×
“Furthermore, a magnetic-field noise level of about tens of fT/Hz1/2 and a wide range of operational magnetic field covering Earth’s magnetic field is attractive for ultralow-field nuclear magnetic resonance [52,53] and for recording bio-magnetic signals from human brain activities [54,55].”
BackgroundSelf-citationSearch for axionlike dark matter through nuclear spin precession in electric and magnetic fields
Abel, C., Ayres, N. J., Ban, G., Bison, G., Bodek, K., Бондар, В. М., Daum, M., Fairbairn, M., Flambaum, V. V., Geltenbort, P. W., et al. (2017) · reroDoc Digital Library · doi:10.3929/ethz-b-000217066 · Cited by 193
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
Search for Axionlike Dark Matter with a Liquid-State Nuclear Spin Comagnetometer
Wu, T., Blanchard, J. W., Centers, G. P., Figueroa, N. L., Garcon, A., Graham, P. W., Kimball, D. F. J., Rajendran, S., Stadnik, Y. V., Sushkov, A. O., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.122.191302 · Cited by 183 · cited 1×
“A magnetically-quiet environment is also important for the fundamental-physics experiments, such as measurements of permanent electric dipole moments (EDMs) [11–13], searches for exotic spin-dependent interactions mediated by hypothetical bosonic fields [14,15], and tests of fundamental symmetries [16–18], acting as a…”
BackgroundSelf-citationSearch for Axionlike Dark Matter through Nuclear Spin Precession in Electric and Magnetic Fields
Abel, C., Ayres, N. J., Ban, G., Bison, G., Bodek, K., Bondar, V., Daum, M., Fairbairn, M., Flambaum, V. V., Geltenbort, P., et al. (2017) · Physical Review X · doi:10.1103/physrevx.7.041034 · Cited by 172
Tayler, M. C. D., Theis, T., Sjolander, T. F., Blanchard, J. W., Kentner, A., Pustelny, S., Pines, A., & Budker, D. (2017) · Review of Scientific Instruments · doi:10.1063/1.5003347 · Cited by 141
Blanchard, J. W., & Budker, D. (2016) · Wiley eBooks · doi:10.1002/9780470034590.emrstm1369 · Cited by 113
Limits of Low Magnetic Field Environments in Magnetic Shields
Sun, Z., Fierlinger, P., Han, J., Li, L., Liu, T., Schnabel, A., Stuiber, S., & Voigt, J. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2987267 · Cited by 109
Nonlinear magneto-optical rotation with amplitude modulated light
Gawlik, W., Krzemień, L., Pustelny, S., Sangla, D., Zachorowski, J., Graf, M., Sushkov, A. O., & Budker, D. (2006) · Applied Physics Letters · doi:10.1063/1.2190457 · Cited by 107
A magnetically shielded room with ultra low residual field and gradient
Altarev, I., Babcock, E., Beck, D., Burghoff, M., Chesnevskaya, S., Chupp, T., Degenkolb, S., Fan, I., Fierlinger, P., Frei, A., et al. (2014) · Review of Scientific Instruments · doi:10.1063/1.4886146 · Cited by 107
A low-noise ferrite magnetic shield
Kornack, T. W., Lee, S. K., Romalis, M. V., & Smullin, S. (2007) · CERN Document Server (European Organization for Nuclear Research) · Cited by 101
Sachdeva, N., Fan, I., Babcock, E., Burghoff, M., Chupp, T. E., Degenkolb, S., Fierlinger, P., Haude, S., Kraegeloh, E., Kilian, W., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.143003 · Cited by 93
A large-scale magnetic shield with 106 damping at millihertz frequencies
Altarev, I., Bales, M., howard, B. D., Chupp, T. E., Fierlinger, K., Fierlinger, P., Kuchler, F., Lins, T., Marino, M. G., Nießen, B., et al. (2015) · Journal of Applied Physics · doi:10.1063/1.4919366 · Cited by 84
Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Sulai, I. A., DeLand, Z. J., Bulatowicz, M. D., Wahl, C. P., Wakai, R. T., & Walker, T. G. (2019) · Review of Scientific Instruments · doi:10.1063/1.5091007 · Cited by 79 · cited 1×
“, using several identical magnetometers inside the magnetic shield and subtracting the measurement results of these magnetometers [28] The noise rejection ratio in the low-frequency region can be improved by actively stabilizing the magnetic field [29–31].”
MethodAfach, S., Bison, G., Bodek, K., Burri, F., Chowdhuri, Z., Daum, M., Fertl, M., Franke, B., Grujić, Z. D., Hélaine, V., et al. (2014) · Journal of Applied Physics · doi:10.1063/1.4894158 · Cited by 76
Experimental benchmarking of quantum control in zero-field nuclear magnetic resonance
Jiang, M., Wu, T., Blanchard, J. W., Feng, G., Peng, X., & Budker, D. (2018) · Science Advances · doi:10.1126/sciadv.aar6327 · Cited by 74
Self-citationPlatzek, D., Nowak, H., Gießler, F., Röther, J., & Eiselt, M. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149779 · Cited by 73 · cited 4×
“In [21], the magnetic field outside the magnetic shield is monitored with SQUID sensors and actively stabilized, realizing a 30-fold improved noise rejection ratio of 2×106 at 0.01 Hz compared with that of the same magnetic shield without field stabilization.”
BackgroundMethodInfluentialConstraints on long-range spin-gravity and monopole-dipole couplings of the proton
Kimball, D. F. J., Dudley, J., Li, Y., Patel, D., & Valdez, J. (2017) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.96.075004 · Cited by 66
Magnetic Gradiometer for the Detection of Zero- to Ultralow-Field Nuclear Magnetic Resonance
Jiang, M., Picazo‐Frutos, R., Wu, T., Blanchard, J. W., Peng, X., & Budker, D. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.024005 · Cited by 53 · cited 1×
“Furthermore, a magnetic-field noise level of about tens of fT/Hz1/2 and a wide range of operational magnetic field covering Earth’s magnetic field is attractive for ultralow-field nuclear magnetic resonance [52,53] and for recording bio-magnetic signals from human brain activities [54,55].”
BackgroundSelf-citationKeviczky, L., Bars, R., Hetthéssy, J., & Bányász, C. (2018) · Advanced textbooks in control and signal processing · doi:10.1007/978-981-10-8297-9 · Cited by 52
Characterization of high-temperature performance of cesium vapor cells with anti-relaxation coating
Li, W., Balabas, M. V., Peng, X., Pustelny, S., Wickenbrock, A., Guo, H. M., & Budker, D. (2017) · Journal of Applied Physics · doi:10.1063/1.4976017 · Cited by 49 · cited 2×
“A circularly-polarized pump laser is used to polarize the cesium atoms in a self-made paraffin coated vapor cell [38].”
BackgroundMethodSelf-citationMagnetic shield for wide-bandwidth magnetic measurements for nondestructive testing and biomagnetism
Ma, Y. P., & Wikswo, J. P. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142195 · Cited by 45
Wide-bandwidth atomic magnetometry via instantaneous-phase retrieval
Wilson, N., Perrella, C., Anderson, R., Luiten, A. N., & Light, P. S. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.013213 · Cited by 42 · cited 2×
“If the magnetometer is operated in the instantaneous-phase retrieval mode, the bandwidth can even go beyond the Larmor frequency [44].”
BackgroundStability and Control of Linear Systems
Bacciotti, A. (2018) · Studies in systems, decision and control · doi:10.1007/978-3-030-02405-5 · Cited by 40
Satellite magnetic field measurements: Applications in studying the deep Earth
Constable, C. G., & Constable, S. (2004) · Geophysical monograph · doi:10.1029/150gm13 · Cited by 36 · cited 1×
“environmental magnetic-field noise has an inverse-power-law frequency dependence and is higher at lower frequencies, the reduced performance of the passive magnetic shielding in suppressing the low-frequency magnetic-field noise needs to be compensated [27].”
BackgroundMicrotesla NMR J-coupling spectroscopy with an unshielded atomic magnetometer
Bevilacqua, G., Biancalana, V., Baranga, A. B.-A., Dancheva, Y. V., & Rossi, C. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.12.018 · Cited by 30 · cited 1×
“Furthermore, a magnetic-field noise level of about tens of fT/Hz1/2 and a wide range of operational magnetic field covering Earth’s magnetic field is attractive for ultralow-field nuclear magnetic resonance [52,53] and for recording bio-magnetic signals from human brain activities [54,55].”
BackgroundExperimental benchmarking of quantum control in zero-field nuclear magnetic resonance
Jiang, M., Wu, T., Blanchard, J. W., Feng, G., Peng, X., & Budker, D. (2018) · GSI Repository (German Federal Government) · Cited by 28
Self-citationHigh-performance magnetically shielded room
Kajiwara, G., Harakawa, K., OGATA, H., & Kado, H. (1996) · IEEE Transactions on Magnetics · doi:10.1109/20.511401 · Cited by 27
Active magnetic shielding for biomagnetic measurement using spatial gradient fields
Hilgenfeld, B., hmel, E. S., Nowak, H., & Haueisen, J. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/3/303 · Cited by 26 · cited 1×
“Many types of magnetometers have been used for active magnetic-field stabilization, including, but not limited to, optically-pumped atomic magnetometer (OPM) [32], superconducting quantum interference device (SQUID) [29], Hall sensor [33], fluxgate [34], and anisotropic magnetoresistive sensor [35].”
MethodMagnetic field stabilization for magnetically shielded volumes by external field coils
Bryś, T., Czekaj, S., Daum, M., Fierlinger, P., George, D. C., Henneck, R., Kasprzak, M., Kirch, K., Kuźniak, M., Kuehne, G., et al. (2005) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2005.08.040 · Cited by 26
Dynamic shielding of the magnetic fields
Baltag, O., Costandache, D., Rau, M. C., Iftemie, A., & Rau, I. (2010) · Advances in Electrical and Computer Engineering · doi:10.4316/aece.2010.04022 · Cited by 26 · cited 1×
“Many types of magnetometers have been used for active magnetic-field stabilization, including, but not limited to, optically-pumped atomic magnetometer (OPM) [32], superconducting quantum interference device (SQUID) [29], Hall sensor [33], fluxgate [34], and anisotropic magnetoresistive sensor [35].”
MethodStray magnetic field compensation with a scalar atomic magnetometer
Belfi, J., Bevilacqua, G., Biancalana, V., Cecchi, R., Dancheva, Y. V., & Moi, L. (2010) · Review of Scientific Instruments · doi:10.1063/1.3441980 · Cited by 23 · cited 1×
“The demonstrated noise rejection ratio of the active magnetic-field stabilization is typically smaller than that of the magnetic shield and ranges from 10 to 1000 [6,29,33,36], depending on the noise level and response properties of the magnetometer and the parameter settings of the feedback controller.”
BackgroundSelf-Adaptive Loop for External-Disturbance Reduction in a Differential Measurement Setup
Bevilacqua, G., Biancalana, V., Dancheva, Y., & Vigilante, A. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.014029 · Cited by 22 · cited 1×
“Many types of magnetometers have been used for active magnetic-field stabilization, including, but not limited to, optically-pumped atomic magnetometer (OPM) [32], superconducting quantum interference device (SQUID) [29], Hall sensor [33], fluxgate [34], and anisotropic magnetoresistive sensor [35].”
MethodResmer, F., Nowak, H., Gießler, F., & Haueisen, J. (2004) · Superconductor Science and Technology · doi:10.1088/0953-2048/17/12/001 · Cited by 18 · cited 1×
“The demonstrated noise rejection ratio of the active magnetic-field stabilization is typically smaller than that of the magnetic shield and ranges from 10 to 1000 [6,29,33,36], depending on the noise level and response properties of the magnetometer and the parameter settings of the feedback controller.”
BackgroundMagnetoencephalography: From Signals to Dynamic Cortical Networks
Taylor, M. J., Urbain, C. M., & Pang, E. E. W. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5 · Cited by 18
Automatic Shielding-Shimming Magnetic Field Compensator for Excluded Volume Applications
Forte, G. O., Farrher, G., Canali, L. R., & Anoardo, E. (2009) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2009.2030174 · Cited by 15 · cited 2×
“Many types of magnetometers have been used for active magnetic-field stabilization, including, but not limited to, optically-pumped atomic magnetometer (OPM) [32], superconducting quantum interference device (SQUID) [29], Hall sensor [33], fluxgate [34], and anisotropic magnetoresistive sensor [35].”
BackgroundMethodNeuromagnetic SQUID measurement in a superconducting magnetic shield
Ohta, H., Aono, M., Matsui, T., Uchikawa, Y., Kobayashi, K., Tanabe, K., Takeuchi, S., Narasaki, K., Tsunematsu, S., Koyabu, Y., et al. (1999) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.783921 · Cited by 15 · cited 1×
“Passive magnetic shielding is widely used for suppressing the magnetic-field noise and is based on multi-layers of high magnetic permeability materials, such as mu-metal [19–24] and ferrite [25], or superconductors [26].”
BackgroundFrequency Response of a Close-Loop Bell-Bloom Magnetometer
Zhang, R., Pang, B., Li, W., Yang, Y., Chen, J., Peng, X., & Guo, H. M. (2018) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2018.8597470 · Cited by 12 · cited 3×
“The bandwidth of the OPM operated under the open-loop mode is determined by the linewidth of the resonance signal and is about 3 Hz in our system, see Figure 1c. Running the same OPM in the closed loop can extend the bandwidth to be larger than ∼1000 Hz, which is determined by the low-pass filter of the LIA [43] and i…”
BackgroundSelf-citationMagnetic field stabilization for magnetically shielded volumes by external field coils
Bryś, T., Czekaj, S., Daum, M., Fierlinger, P., George, D. C., Henneck, R., Hochman, Z., Kasprzak, M., Kohlik, K., Kirch, K., et al. (2005) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.110.020 · Cited by 8
Stability of Linear Control Systems
Keviczky, L., Bars, R., Hetthéssy, J., & Bányász, C. (2018) · Advanced textbooks in control and signal processing · doi:10.1007/978-981-10-8321-1_5 · Cited by 3 · cited 1×
“An accurate and complete analysis on the system status is based on the Nyquist stability criterion by examining the roots of the equation 1 + FR(s)× FB(s)× MG(s) = 0 [49,50].”
MethodDescription of Continuous Linear Systems in the Time, Operator and Frequency Domain
Keviczky, L., Bars, R., Hetthéssy, J., & Bányász, C. (2018) · Advanced textbooks in control and signal processing · doi:10.1007/978-981-10-8297-9_2 · Cited by 3 · cited 1×
“The transfer function theoretically models a linear-time-invariant (LTI) system’s output for each possible input [48] and provides a direct way to quantitatively analyze the system’s characteristics, such as the stability and the frequency response.”
BackgroundZhang, R., Pang, B., Ding, Y., Li, W., Chen, J., Peng, X., & Guo, H. M. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8856049 · Cited by 3 · cited 5×
“The vapor cell, together with the optical components such as the wave plates, polarizers, and mirrors, are mounted in a 3D-printed structure, which has a size of 5× 24× 27 cm3 and is placed at the center of the coils [37].”
BackgroundMethodSelf-citationDesign of Conventional Regulators
Keviczky, L., Bars, R., Hetthéssy, J., & Bányász, C. (2018) · Advanced textbooks in control and signal processing · doi:10.1007/978-981-10-8297-9_8 · Cited by 1 · cited 1×
“The readout from the OPM sensor is used as an input signal for the feedback controller, which consists of PID modules (Proportion-Integration-Differentiation, Stanford Research Systems, SIM960) [45] and a VOC source (voltage-controlled current, Stanford Research Systems, LDC501).”
Method
Research works printed but not linked: 3
- Bork, J., Hahlbohm, H., Klein, R., and Schnabel, A. (2000, January 13–17). The 8-layered magnetically shielded room of the PTB: Design and construction. Proceedings of the 12th International Conference on Biomagnetism (Biomag2000), Espoo, Finland.
- Keviczky, L., Bars, R., Hetthéssy, J., and Bányász, C. (2019). Control Engineering, Springer. · DOI
- Keviczky, L., Bars, R., Hetthéssy, J., and Bányász, C. (2019). Proofs and derivations (by chapters). Control Engineering, Springer. · DOI
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“If we want to realize a high CMRR in a low-frequency band for MCG signals, then the OPMs should have wide bandwidths, which usually benefit the consistency of OPMs ( 51 ).”
Self-citationSensitive magnetometry in challenging environments
Fu, K. C., Iwata, G. Z., Wickenbrock, A., & Budker, D. (2020) · AVS Quantum Science · doi:10.1116/5.0025186 · Cited by 132
Two-photon electromagnetic induction imaging with an atomic magnetometer
Maddox, B., & Renzoni, F. (2023) · Applied Physics Letters · doi:10.1063/5.0147291 · Cited by 19
VCSEL frequency stabilization for optically pumped magnetometers
Yan, Y., Liu, G., Lin, H., Yin, K., Wang, K., & Lu, J. (2021) · Chinese Optics Letters · doi:10.3788/col202119.121407 · Cited by 16
Tian, P., Le, Y., Zhang, H., & Zheng, S. (2025) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2025.3538134 · Cited by 14
Metadata
- Authors
- Zhang, R., Ding, Y., Yang, Y., Zheng, Z., Chen, J., Peng, X., Wu, T., & Guo, H.
- Affiliations
- National University of Defense Technology (CN)
- Peking University (CN)
- Corresponding author
- Guo, Hong
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-07-30
- Volume
- 20
- Issue
- 15
- Pages
- 4241
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7435849
- OpenAlex
- W3046171984
- Cited by
- 32
- References
- 58
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 5 · 2023: 6 · 2022: 6 · 2021: 4 · 2020: 2
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- the National Natural Science Foundation of China (No. 61571018, No. 61531003, No. 91436210)
- the National Science Fund for Distinguished Young Scholars of China (No. 61225003)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Keywords
- atomic magnetometer, magnetic noise, optically pumped magnetometers, magnetic shielding, magnetic field compensation, spin-dependent interactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.