A magnetically-quiet environment is important for detecting faint magnetic-field signals or nonmagnetic spin-dependent interactions. Passive magnetic shielding using layers of large magnetic-permeability materials is widely used to reduce the magnetic-field noise. The magnetic-field noise can also be actively monitored with magnetometers and then compensated, acting as a complementary method to the passive shielding. We present here a general model to quantitatively depict and optimize the performance of active magnetic-field stabilization and experimentally verify our model using optically-pumped atomic magnetometers. We experimentally demonstrate a magnetic-field noise rejection ratio of larger than ∼800 at low frequencies and an environment with a magnetic-field noise floor of ∼40 fT/Hz1/2 in unshielded Earth’s field. The proposed model provides a general guidance on analyzing and improving the performance of active magnetic-field stabilization with magnetometers. This work offers the possibility of sensitive detections of magnetic-field signals in a variety of unshielded natural environments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s20154241

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Active magnetic-field stabilization using optically-pumped atomic magnetometers (OPMs). (a) Schematics of the active magnetic-field stabilization system. The OPMs are placed in the center of two sets of Helmholtz coils. The readout from the bottom OPM sensor, OPM-S, is used as an input signal for the feedback controller (the PID modules and the voltage-controlled current source), which drives the inner layer of coils to compensate for the magnetic-field fluctuations. (b) Schematics of the OPM sensors. The Cs vapor cell is kept at room temperature. A circularly-polarized pump beam is amplitude modulated to synchronize the Larmor precession of the atomic spins. The optical rotation of a linearly-polarized probe beam is used to monitor the Larmor precession of the atomic spins. (c) A typical magnetic resonance signal of our OPM sensor in a 20,000 nT bias field. (d) The block diagram of the magnetic-field stabilization system. BE(s): the environmental magnetic-field variation in the Laplace domain, BC(s): the magnetic field produced by the inner layer of coils to actively compensate for the magnetic-field variation, BS(s): the noise-suppressed magnetic field and is equal to BE(s)−BC(s), FR(s): the transfer function of the bottom OPM sensor, Setpoint: the target magnetic field to be stabilized to and is unchanged during the experiment, FB(s): the transfer function of the feedback controller, MG(s): the transfer function of the magnetic-field generator, or the inner layer of coils.
Figure 1 Active magnetic-field stabilization using optically-pumped atomic magnetometers (OPMs). (a) Schematics of the active magnetic-field stabilization system. The OPMs are placed in the center of two sets of Helmholtz coils. The readout from the bottom OPM sensor, OPM-S, is used as an input signal for the feedback controller (the PID modules and the voltage-controlled current source), which drives the inner layer of coils to compensate for the magnetic-field fluctuations. (b) Schematics of the OPM sensors. The Cs vapor cell is kept at room temperature. A circularly-polarized pump beam is amplitude modulated to synchronize the Larmor precession of the atomic spins. The optical rotation of a linearly-polarized probe beam is used to monitor the Larmor precession of the atomic spins. (c) A typical magnetic resonance signal of our OPM sensor in a 20,000 nT bias field. (d) The block diagram of the magnetic-field stabilization system. BE(s): the environmental magnetic-field variation in the Laplace domain, BC(s): the magnetic field produced by the inner layer of coils to actively compensate for the magnetic-field variation, BS(s): the noise-suppressed magnetic field and is equal to BE(s)−BC(s), FR(s): the transfer function of the bottom OPM sensor, Setpoint: the target magnetic field to be stabilized to and is unchanged during the experiment, FB(s): the transfer function of the feedback controller, MG(s): the transfer function of the magnetic-field generator, or the inner layer of coils.CC BY · PubMed Central
Figure 2 Optimization of the active magnetic-field stabilization system. (a) Amplitude–frequency responses of the feedback controller and the magnetometer. (b) Phase–frequency responses of the feedback controller and the magnetometer. (c) The calculated noise rejection ratios under different parameter settings of the feedback controller. The dashed black lines in (a,b) are the calculated amplitude- and phase- frequency responses of the magnetometer. The solid lines in (a,b) are the calculated amplitude- and phase- frequency responses of −1/[FB(s)×MG(s)]. Different colors of the lines indicate different parameters of the feedback controllers, i.e., orange (blue) for a PID module with a small (big) integration coefficient KI, and green for a PI²D module.
Figure 2 Optimization of the active magnetic-field stabilization system. (a) Amplitude–frequency responses of the feedback controller and the magnetometer. (b) Phase–frequency responses of the feedback controller and the magnetometer. (c) The calculated noise rejection ratios under different parameter settings of the feedback controller. The dashed black lines in (a,b) are the calculated amplitude- and phase- frequency responses of the magnetometer. The solid lines in (a,b) are the calculated amplitude- and phase- frequency responses of −1/[FB(s)×MG(s)]. Different colors of the lines indicate different parameters of the feedback controllers, i.e., orange (blue) for a PID module with a small (big) integration coefficient KI, and green for a PI²D module.CC BY · PubMed Central
Figure 3 Noise rejection ratio of the active magnetic-field stabilization system. The green triangles and light blue circles show the experimentally measured noise rejection ratios using a PID module and a PI²D module, respectively. The calculated noise rejection ratios using a PID module and a PI²D module are shown by the black dashed line and dark blue solid line, respectively.
Figure 3 Noise rejection ratio of the active magnetic-field stabilization system. The green triangles and light blue circles show the experimentally measured noise rejection ratios using a PID module and a PI²D module, respectively. The calculated noise rejection ratios using a PID module and a PI²D module are shown by the black dashed line and dark blue solid line, respectively.CC BY · PubMed Central
Figure 4 Noise spectral density (NSD) measured with the OPM sensors after active magnetic-field stabilization under different strength of bias magnetic field. (a) The NSD of OPM-M sensor, i.e., the magnetometer used for monitoring the magnetic-field noise after magnetic-field stabilization. (b) The NSD of OPM-S, i.e., the magnetometer used for magnetic-field stabilization. (c) The NSD of the gradiometer. (d) The NSD of OPM-M, OPM-S, and the gradiometer at 10 Hz under different strength of bias magnetic field.
Figure 4 Noise spectral density (NSD) measured with the OPM sensors after active magnetic-field stabilization under different strength of bias magnetic field. (a) The NSD of OPM-M sensor, i.e., the magnetometer used for monitoring the magnetic-field noise after magnetic-field stabilization. (b) The NSD of OPM-S, i.e., the magnetometer used for magnetic-field stabilization. (c) The NSD of the gradiometer. (d) The NSD of OPM-M, OPM-S, and the gradiometer at 10 Hz under different strength of bias magnetic field.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 3

  1. Bork, J., Hahlbohm, H., Klein, R., and Schnabel, A. (2000, January 13–17). The 8-layered magnetically shielded room of the PTB: Design and construction. Proceedings of the 12th International Conference on Biomagnetism (Biomag2000), Espoo, Finland.
  2. Keviczky, L., Bars, R., Hetthéssy, J., and Bányász, C. (2019). Control Engineering, Springer. · DOI
  3. Keviczky, L., Bars, R., Hetthéssy, J., and Bányász, C. (2019). Proofs and derivations (by chapters). Control Engineering, Springer. · DOI

Cited by

See all 32

Metadata

Authors
Zhang, R., Ding, Y., Yang, Y., Zheng, Z., Chen, J., Peng, X., Wu, T., & Guo, H.
Affiliations
  • National University of Defense Technology (CN)
  • Peking University (CN)
Corresponding author
Guo, Hong
Venue
Sensors
Publisher
MDPI AG
Published
2020-07-30
Volume
20
Issue
15
Pages
4241
ISSN
1424-8220 (ISSN-L)
OpenAlex
W3046171984
Cited by
32
References
58
Citations by year
2026: 3 · 2025: 6 · 2024: 5 · 2023: 6 · 2022: 6 · 2021: 4 · 2020: 2
FWCI
1.83
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • the National Natural Science Foundation of China (No. 61571018, No. 61531003, No. 91436210)
  • the National Science Fund for Distinguished Young Scholars of China (No. 61225003)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
Keywords
atomic magnetometer, magnetic noise, optically pumped magnetometers, magnetic shielding, magnetic field compensation, spin-dependent interactions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.