Recent Progress of Fiber-Optic Sensors for the Structural Health Monitoring of Civil Infrastructure
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In recent years, with the development of materials science and architectural art, ensuring the safety of modern buildings is the top priority while they are developing toward higher, lighter, and more unique trends. Structural health monitoring (SHM) is currently an extremely effective and vital safeguard measure. Because of the fiber-optic sensor’s (FOS) inherent distinctive advantages (such as small size, lightweight, immunity to electromagnetic interference (EMI) and corrosion, and embedding capability), a significant number of innovative sensing systems have been exploited in the civil engineering for SHM used in projects (including buildings, bridges, tunnels, etc.). The purpose of this review article is devoted to presenting a summary of the basic principles of various fiber-optic sensors, classification and principles of FOS, typical and functional fiber-optic sensors (FOSs), and the practical application status of the FOS technology in SHM of civil infrastructure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magalhães, F., Cunha, A., & Caetano, E. (2012) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2011.06.011 · Cited by 655
Goyal, D., & Pabla, B. S. (2016) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-015-9145-0 · Cited by 508
Fibre optic sensors for the structural health monitoring of building structures
Bremer, K., Wollweber, M., Weigand, F., Rahlves, M., Kuhne, M., Helbig, R., & Roth, B. (2016) · Procedia Technology · doi:10.1016/j.protcy.2016.08.065 · Cited by 96
Cited by
Optical Fiber Sensors and Sensing Networks: Overview of the Main Principles and Applications
Pendão, C., & Silva, I. (2022) · Sensors · doi:10.3390/s22197554 · Cited by 305
Recent Advancements in Non-Destructive Testing Techniques for Structural Health Monitoring
Kot, P., Muradov, M., Gkantou, M., Kamaris, G. S., Hashim, K., & Yeboah, D. (2021) · Applied Sciences · doi:10.3390/app11062750 · Cited by 279
“A FOS is a cylindrical symmetric structure, which comprises a central core with a diameter between 4 and 600 µm and a uniform refractive index [31].”
InfluentialHassani, S., & Dackermann, U. (2023) · Sensors · doi:10.3390/s23063293 · Cited by 146
AI in structural health monitoring for infrastructure maintenance and safety
Plevris, V., & Papazafeiropoulos, G. (2024) · Infrastructures · doi:10.3390/infrastructures9120225 · Cited by 132
Metadata
- Authors
- Wu, T., Liu, G., Fu, S., & Xing, F.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-08-12
- Volume
- 20
- Issue
- 16
- Pages
- 4517
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3048601677
- Cited by
- 204
- References
- 3
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.