Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A 64-channel 0.13-μm CMOS system on a chip (SoC) for neuroelectrical monitoring and responsive neurostimulation is presented. The ΔΣ-based neural channel records signals with rail-to-rail dc offset at the input without any area-intensive dc-removing passive components, which leads to a compact 0.013-mm2integration area of recording and stimulation circuits. The channel consumes 630 nW, yields a signal to noise and distortion ratio of 72.2 dB, a 1.13-μVrms integrated input-referred noise over 0.1-500 Hz frequency range, and a noise efficiency factor of 2.86. Analog multipliers are implemented in each channel with minimum additional area cost by reusing the multi-bit current-digital to analog converter that is originally placed for current-mode stimulation. The multipliers are used for compact implementation of bandpass finite impulse response filters, as well as voltage gain scaling. A tri-core low-power DSP conducts phase-synchrony-based neurophysiological event detection and triggers a subset of 64 programmable arbitrary-waveform current-mode stimulators for subsequent neuromodulation. Two ultra-wideband (UWB) wireless transmitters communicate to receivers located at 10 cm to 2 m distance from the implanted SoC with data rates of 10-46 Mb/s, respectively. An inductive link that operates at 1.5 MHz provides power to the SoC and is also used to communicate commands to an on-chip ASK receiver. The chip occupies 6 mm2while consuming 1.07 and 5.44 mW with delay-based and voltage controlled oscillator-based UWB transmitters, respectively. The SoC is validated in vivo using epilepsy monitoring (seizure detection) and treatment (seizure suppression) experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A model of safe levels for electrical stimulation
Shannon, R. V. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126616 · Cited by 526 · cited 1×
“The stimulation current was chosen according to safety considerations [36], which was three times lower than the maximum deliverable”
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
Cited by
Kim, C., Joshi, S., Courellis, H., Wang, J., Miller, C., & Cauwenberghs, G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2870555 · Cited by 104
Uehlin, J. P., Smith, W. A., Pamula, V. R., Pepin, E. P., Perlmutter, S., Sathe, V., & Rudell, J. C. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991524 · Cited by 81
“[11], [26]–[28], dynamic voltage supplies save energy when stimulating below the maximum output voltage [29].”
BackgroundTrack-and-Zoom Neural Analog-to-Digital Converter With Blind Stimulation Artifact Rejection
Reza Pazhouhandeh, M., Chang, M., Valiante, T. A., & Genov, R. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.2991526 · Cited by 74
“efficient spectrum equalizing techniques [17], [23], which do not require high dynamic range amplifiers, allow hosting of”
BackgroundSelf-citationDabbaghian, A., Yousefi, T., Fatmi, S. Z., Shafia, P., & Kassiri, H. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2936327 · Cited by 56
Self-citationRozgic, D., Hokhikyan, V., Jiang, W., Akita, I., Basir - Kazeruni, S., Chandrakumar, H., & Markovic, D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2889040 · Cited by 49
Metadata
- Authors
- Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Perez Velazquez, J. L., Carlen, P., & Genov, R.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2017
- Pages
- 1-18
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2767011766
- Cited by
- 160
- References
- 4
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator. https://app.cochat.ai/papers/10.1109/jssc.2017.2749426
- The paper
- Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Perez Velazquez, J. L., Carlen, P., & Genov, R. (2017). Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2017.2749426
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.