Influence of Artefact Correction and Recording Device Type on the Practical Application of a Non-Linear Heart Rate Variability Biomarker for Aerobic Threshold Determination
Open accessAbstract
Recent study points to the value of a non-linear heart rate variability (HRV) biomarker using detrended fluctuation analysis (DFA a1) for aerobic threshold determination (HRVT). Significance of recording artefact, correction methods and device bias on DFA a1 during exercise and HRVT is unclear. Gas exchange and HRV data were obtained from 17 participants during an incremental treadmill run using both ECG and Polar H7 as recording devices. First, artefacts were randomly placed in the ECG time series to equal 1, 3 and 6% missed beats with correction by Kubios software’s automatic and medium threshold method. Based on linear regression, Bland Altman analysis and Wilcoxon paired testing, there was bias present with increasing artefact quantity. Regardless of artefact correction method, 1 to 3% missed beat artefact introduced small but discernible bias in raw DFA a1 measurements. At 6% artefact using medium correction, proportional bias was found (maximum 19%). Despite this bias, the mean HRVT determination was within 1 bpm across all artefact levels and correction modalities. Second, the HRVT ascertained from synchronous ECG vs. Polar H7 recordings did show an average bias of minus 4 bpm. Polar H7 results suggest that device related bias is possible but in the reverse direction as artefact related bias.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Artifact correction can lead to variable results in terms of DFA a1 bias during incremental tests.
“In terms of DFA a1 bias during the incremental tests, artifact correction can lead to variable results [24].”
From Validity of the Polar H10 Sensor for Heart Rate Variability Analysis during Resting State and Incremental Exercise in Recreational Men and Women (2022) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · see citing works
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · see citing works
Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series
Peng, C., Havlin, S., Stanley, E., & Goldberger, A. L. (1995) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166141 · Cited by 3,865 · see citing works
Kubios HRV–heart rate variability analysis software.
Tarvainen, M. P., Niskanen, J.-P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.07.024 · Cited by 2,720 · cited 2× · see citing works
“Kubios preprocessing settings were at the default values including the RR detrending method which was kept at “Smoothn priors” (Lambda = 500 [22]).”
MethodBiostatistics 104: correlational analysis.
Chan, Y. H. (2003) · PubMed · Cited by 1,223 · see citing works
Monitoring training status with HR measures: do all roads lead to Rome?
Buchheit, M. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00073 · Cited by 909 · see citing works
Michael, S., Graham, K. S., & Davis, G. M. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00301 · Cited by 626 · see citing works
Validity and reliability of combining three methods to determine ventilatory threshold
GASKILL, S. E., RUBY, B. C., WALKER, A. J., SANCHEZ, O. A., SERFASS, R. C., & LEON, A. S. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00007 · Cited by 444 · see citing works
RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise
Gilgen-Ammann, R., Schweizer, T., & Wyss, T. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04142-5 · Cited by 438 · see citing works
Lipponen, J. A., & Tarvainen, M. P. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1640306 · Cited by 374 · see citing works
Confidence in Altman–Bland plots: A critical review of the method of differences
Ludbrook, J. (2009) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2009.05288.x · Cited by 369 · see citing works
Plews, D. J., Scott, B., Altini, M., Wood, M., Kilding, A. E., & Laursen, P. B. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0668 · Cited by 323 · see citing works
Role of editing of R–R intervals in the analysis of heart rate variability
Peltola, M. A. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00148 · Cited by 306 · see citing works
Reporting Standards for a Bland–Altman Agreement Analysis: A Review of Methodological Reviews
Gerke, O. (2020) · Diagnostics · doi:10.3390/diagnostics10050334 · Cited by 246 · see citing works
Kingsley, M., Lewis, M. J., & Marson, R. E. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-817878 · Cited by 230 · see citing works
ECG artifacts and heart period variability: Don't miss a beat!
Berntson, G. G., & Stowell, J. R. (1998) · Psychophysiology · doi:10.1111/1469-8986.3510127 · Cited by 223 · see citing works
Accuracy of commercially available heart rate monitors in athletes: a prospective study
Pasadyn, S. R., Soudan, M., Gillinov, M., Houghtaling, P., Phelan, D., Gillinov, N., Bittel, B., & Desai, M. Y. (2019) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2019.06.05 · Cited by 135 · see citing works
Short‐term correlation properties of R–R interval dynamics at different exercise intensity levels
Hautala, A. J., Mäkikallio, T. H., Seppänen, T., Huikuri, H. V., & Tulppo, M. P. (2003) · Clinical Physiology and Functional Imaging · doi:10.1046/j.1475-097x.2003.00499.x · Cited by 134 · see citing works
A Note on the Influence of Outliers on Parametric and Nonparametric Tests
Zimmerman, D. W. (1994) · The Journal of General Psychology · doi:10.1080/00221309.1994.9921213 · Cited by 132 · see citing works
Porto, L. G. G., & Junqueira, L. F. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02175.x · Cited by 130 · see citing works
Caminal, P., Sola, F., Gomis, P., Guasch, E., Perera-Lluna, A., Soriano, N. P., & Mont, L. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-3808-0 · Cited by 108 · see citing works
Correlation properties of heart rate variability during endurance exercise: A systematic review
Gronwald, T., & Hoos, O. (2019) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12697 · Cited by 101 · see citing works
Self-citationAlcántara, J. M. A., Plaza‐Florido, A., Amaro‐Gahete, F. J., Acosta, F. M., Migueles, J. H., Molina‐García, P., Sacha, J., Sánchez‐Delgado, G., & Martínez‐Téllez, B. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020325 · Cited by 97 · see citing works
Non-Linear Analyses of Heart Rate Variability During Heavy Exercise and Recovery in Cyclists
CASTIES, J. F. O., Mottet, D., & Gallais, D. L. (2006) · International Journal of Sports Medicine · doi:10.1055/s-2005-872968 · Cited by 92 · see citing works
Rogers, B., Giles, D., Draper, N., Hoos, O., & Gronwald, T. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2020.596567 · Cited by 91 · see citing works
Self-citationGronwald, T., Rogers, B., & Hoos, O. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.550572 · Cited by 86 · see citing works
Self-citationHeart Rate Variability During Exercise: A Comparison of Artefact Correction Methods
Giles, D., & Draper, N. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001800 · Cited by 65 · see citing works
Self-citationThe impact of artifact correction methods of RR series on heart rate variability parameters
Soler, A. I. R., Silva, L. E. V., Fazan, R., & Murta, L. O. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00927.2016 · Cited by 58 · see citing works
An Analysis of the Effects of Noisy Electrocardiogram Signal on Heartbeat Detection Performance
Apandi, Z. F. M., Ikeura, R., Hayakawa, S., & Tsutsumi, S. (2020) · Bioengineering · doi:10.3390/bioengineering7020053 · Cited by 52 · see citing works
Non-linear dynamics of heart rate variability during incremental cycling exercise
Gronwald, T., Hoos, O., Ludyga, S., & Hottenrott, K. (2018) · Research in Sports Medicine · doi:10.1080/15438627.2018.1502182 · Cited by 44 · see citing works
Self-citationStapelberg, N. J. C., Neumann, D. L., Shum, D., McConnell, H. W., & Hamilton‐Craig, I. R. (2017) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12483 · Cited by 38 · see citing works
Gronwald, T., Hoos, O., & Hottenrott, K. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020194 · Cited by 36 · see citing works
Self-citationPeltola, M. A., Seppänen, T., Mäkikallio, T. H., & Huikuri, H. V. (2004) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2004.92531.x · Cited by 31 · see citing works
Effectiveness of the Chest Strap Electrocardiogram to Detect Atrial Fibrillation
Hartikainen, S., Lipponen, J. A., Hiltunen, P., Rissanen, T. T., Kolk, I., Tarvainen, M. P., Martikainen, T. J., Castrén, M. K., Väliaho, E., & Jäntti, H. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.02.028 · Cited by 31 · see citing works
Tapanainen, J. M., Seppänen, T., Laukkanen, R. M. T., et al. (1999) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.1999.tb00359.x · Cited by 27 · see citing works
Non-linear dynamics of cardiac autonomic activity during cycling exercise with varied cadence
Gronwald, T., Ludyga, S., Hoos, O., & Hottenrott, K. (2018) · Human Movement Science · doi:10.1016/j.humov.2018.06.013 · Cited by 23 · see citing works
Self-citationRibeiro, G. D. S., Neves, V. R., Deresz, L. F., Melo, R. D., Lago, P. D., & Karsten, M. (2018) · Brazilian Journal of Physical Therapy · doi:10.1016/j.bjpt.2018.03.008 · Cited by 22 · see citing works
Accuracy of the Garmin 920 XT HRM to perform HRV analysis
Cassirame, J., Vanhaesebrouck, R., Chevrolat, S., & Mourot, L. (2017) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-017-0593-8 · Cited by 20 · see citing works
Self-citationHeart Rate Variability Analysis in Exercise Physiology
Hottenrott, K., & Hoos, O. (2017) · CRC Press eBooks · doi:10.4324/9781315372921-11 · Cited by 20 · see citing works
ECG Time Series Variability Analysis
Porta, A., Faes, L., Nollo, G., et al. (2017) · CRC Press eBooks · doi:10.4324/9781315372921 · Cited by 20 · see citing works
Gronwald, T., Hoos, O., & Hottenrott, K. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00999 · Cited by 16 · see citing works
Self-citationEffects of R-R time series accuracy on heart rate variability indexes
Cassirame, J., Chevrolat, S., & Mourot, L. (2019) · Movement & Sport Sciences - Science & Motricité · doi:10.1051/sm/2019006 · Cited by 10 · see citing works
Self-citationNonlinear forecasting and the dynamics of cardiac rhythm
Lippman, N., Steín, K. M., & Lerman, B. B. (1995) · Journal of Electrocardiology · doi:10.1016/s0022-0736(95)80018-2 · Cited by 8 · see citing works
Jiang, X., Guo, X., Zhang, N., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0195894 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Schaffarczyk, M., Rogers, B., Reer, R., & Gronwald, T. (2022) · Sensors · doi:10.3390/s22176536 · Cited by 349 · see citing works
Self-citation
- Authors
- Rogers, B., Giles, D., Draper, N., Mourot, L., & Gronwald, T.
- Affiliations
- University of Central Florida (US)
- Lattice Training Ltd., Chesterfield S41 9AT, UK
- University of Canterbury (NZ)
- Tomsk Polytechnic University (RU)
- MSH Medical School Hamburg – University of Applied Sciences and Medical University (DE)
- Corresponding author
- Rogers, Bruce
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-01-26
- Volume
- 21
- Issue
- 3
- Pages
- 821
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7865269
- OpenAlex
- W3124184716
- Cited by
- 54
- References
- 44
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 13 · 2023: 12 · 2022: 8 · 2021: 5
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- University of Canterbury Research Repository (University of Canterbury) (submittedVersion, cc-by)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- heart rate variability, aerobic threshold, detrended fluctuation analysis, artifact removal, ECG, gas exchange
- MeSH terms
- Electrocardiography, Exercise Test, Heart Rate, Humans, Biomarkers, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review