Review of Recent Microwave Planar Resonator-Based Sensors: Techniques of Complex Permittivity Extraction, Applications, Open Challenges and Future Research Directions
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Recent developments in the field of microwave planar sensors have led to a renewed interest in industrial, chemical, biological and medical applications that are capable of performing real-time and non-invasive measurement of material properties. Among the plausible advantages of microwave planar sensors is that they have a compact size, a low cost and the ease of fabrication and integration compared to prevailing sensors. However, some of their main drawbacks can be considered that restrict their usage and limit the range of applications such as their sensitivity and selectivity. The development of high-sensitivity microwave planar sensors is required for highly accurate complex permittivity measurements to monitor the small variations among different material samples. Therefore, the purpose of this paper is to review recent research on the development of microwave planar sensors and further challenges of their sensitivity and selectivity. Furthermore, the techniques of the complex permittivity extraction (real and imaginary parts) are discussed based on the different approaches of mathematical models. The outcomes of this review may facilitate improvements of and an alternative solution for the enhancement of microwave planar sensors’ normalized sensitivity for material characterization, especially in biochemical and beverage industry applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Material Characterization Using Complementary Split-Ring Resonators
BOYBAY, M. S., & Ramahi, O. M. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2203450 · Cited by 491 · cited 2×
“A variety of microwave planar sensors are used for material characterization and their constituents in order to be used for monitoring in the food industry and for biomedical and quality control purposes [44,165,166].”
BackgroundMethodMetamaterial-based microfluidic sensor for dielectric characterization
Withayachumnankul, W., Jaruwongrungsee, K., Tuantranont, A., Fumeaux, C., & Abbott, D. (2013) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2012.10.027 · Cited by 473 · cited 4×
“[16] Sensors Actuators A: Physical SRR PET film microfluidic channel 2.”
BackgroundInfluentialStrongly Enhanced Sensitivity in Planar Microwave Sensors Based on Metamaterial Coupling
Abdolrazzaghi, M., Daneshmand, M., & Iyer, A. K. (2018) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2018.2791942 · Cited by 353 · cited 4×
“[95] IEEE Transactions on Microwave Theory and Techniques Metamaterial coupling 2.”
BackgroundMethodResultInfluentialAn overview of dielectric properties measuring techniques
Raghavan, M. S. V. A. G. S. V. (2005) · Cited by 331
Chemical and Biological Sensors for Food-Quality Monitoring and Smart Packaging
Mustafa, F., & Andreescu, S. (2018) · Foods · doi:10.3390/foods7100168 · Cited by 329
Chuma, E. L., Iano, Y., Fontgalland, G. F., & Roger, L. L. B. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2872859 · Cited by 310 · cited 1×
“[15] IEEE Sensors Journal CSRR Glass capillary 2.”
BackgroundCurrent development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269
Biosensing using split-ring resonators at microwave regime
Lee, H.-J., & Yook, J.-G. (2008) · Applied Physics Letters · doi:10.1063/1.2946656 · Cited by 262 · cited 2×
“Figure 17 demonstrates the measurement of the quality factor obtained from the scattering parameter S21 based on the bandpass [36,85,86] and bandstop responses [16,76,88–91].”
MethodComplementary Split-Ring Resonator-Loaded Microfluidic Ethanol Chemical Sensor
Salim, A., & Lim, S. (2016) · Sensors · doi:10.3390/s16111802 · Cited by 253
Microwave reflective biosensor for glucose level detection in aqueous solutions
Ebrahimi, A., Scott, J., & Ghorbani, K. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2019.111662 · Cited by 223 · cited 2×
“[107] Sensors and Actuators, A: Physical Microwave reflective 2.”
Background
Cited by
Noninvasive Glucose Sensing in Aqueous Solutions Using an Active Split-Ring Resonator
Abdolrazzaghi, M., Katchinskiy, N., Elezzabi, A. Y., Light, P. E., & Daneshmand, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3090050 · Cited by 207
Resistive Measurement Method for MQ Sensors Based on ADCs of Microcontrollers
Kaunkid, S., Aurasopon, A., Khamsen, W., Takeang, C., Piladaeng, N., & Lloret, J. (2024) · IEEE Access · doi:10.1109/access.2024.3472697 · Cited by 14
“This sensor is less affected by environmental factors such as humidity or temperature variations, ensuring consistent performance in diverse operating conditions [1], [2].”
Background
Metadata
- Authors
- Alahnomi, R. A., Zakaria, Z., Yussof, Z. M., Althuwayb, A. A., Alhegazi, A., Alsariera, H., & Rahman, N. A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-03-24
- Volume
- 21
- Issue
- 7
- Pages
- 2267
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3137747229
- Cited by
- 200
- References
- 46
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review of Recent Microwave Planar Resonator-Based Sensors: Techniques of Complex Permittivity Extraction, Applications, Open Challenges and Future Research Directions. https://app.cochat.ai/papers/10.3390/s21072267
- The paper
- Alahnomi, R. A., Zakaria, Z., Yussof, Z. M., Althuwayb, A. A., Alhegazi, A., Alsariera, H., & Rahman, N. A. (2021). Review of Recent Microwave Planar Resonator-Based Sensors: Techniques of Complex Permittivity Extraction, Applications, Open Challenges and Future Research Directions. Sensors. https://doi.org/10.3390/s21072267
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.