Reducing Noise, Artifacts and Interference in Single-Channel EMG Signals: A Review
Open accessThe DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Abstract
Electromyography (EMG) is gaining importance in many research and clinical applications, including muscle fatigue detection, control of robotic mechanisms and prostheses, clinical diagnosis of neuromuscular diseases and quantification of force. However, EMG signals can be contaminated by various types of noise, interference and artifacts, leading to potential data misinterpretation. Even assuming best practices, the acquired signal may still contain contaminants. The aim of this paper is to review methods employed to reduce the contamination of single channel EMG signals. Specifically, we focus on methods which enable a full reconstruction of the EMG signal without loss of information. This includes subtraction methods used in the time domain, denoising methods performed after the signal decomposition and hybrid approaches that combine multiple methods. Finally, this paper provides a discussion on the suitability of the individual methods based on the type of contaminant(s) present in the signal and the specific requirements of the application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yaşlı Kadınlarda Üreme Sağlığı
Kokanalı, D., & Engin Üstün, Y. (n.d.) · DergiPark (Istanbul University) · Cited by 170,090
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564 · cited 1×
“[95] developed a new decomposition method called the empirical-mode decomposition.”
MethodVariational Mode Decomposition
Dragomiretskiy, K., & Zosso, D. (2014) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2288675 · Cited by 9,184 · cited 1×
“[107] have developed a new decomposition method called variational mode decomposition (VMD).”
MethodIdeal spatial adaptation by wavelet shrinkage
Donoho, D. L., & Johnstone, I. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.425 · Cited by 8,760 · cited 3×
“Since [91] published their method, several other threshold selection procedures have also been explored.”
MethodInfluentialENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715 · cited 1×
“[100] used an extension of EMD called the ensemble EMD (EEMD) developed by [101].”
MethodAdaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Mallat, S. (1999) · A Wavelet Tour of Signal Processing · doi:10.1016/b978-012466606-1/50008-8 · Cited by 1,770
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629 · cited 2×
“Indeed, the relative contribution of all frequency components in the EMG signal should remain untouched [29].”
BackgroundCOMPLEMENTARY ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOVEL NOISE ENHANCED DATA ANALYSIS METHOD
YEH, J.-R., SHIEH, J.-S., & HUANG, N. E. (2010) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536910000422 · Cited by 1,510 · cited 1×
“An improved algorithm derived from the EEMD was also introduced by [103].”
MethodIEEE Transactions on Signal Processing
(2023) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.78 · Cited by 1,455
IEEE Transactions on Biomedical Engineering
(2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.10 · Cited by 1,400
Filtering the surface EMG signal: Movement artifact and baseline noise contamination
De Luca, C. J., Donald Gilmore, L., Kuznetsov, M., & Roy, S. H. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.01.027 · Cited by 1,277 · cited 6×
“Baseline noise (BL), also referred to as inherent noise, represents the signal detected by the equipment when the muscle is not contracted [10].”
BackgroundMethodInfluentialComputer methods and programs in biomedicine
(1985) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(85)90039-2 · Cited by 1,151
Surface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000 · cited 1×
“In terms of the optimal decomposition level, level 4 appears to be the most widely used [5,19,71,77,82,85,86], while the level 3 is also frequently chosen [25,72,87–90].”
BackgroundDevelopment of EMD-Based Denoising Methods Inspired by Wavelet Thresholding
Kopsinis, Y., & McLaughlin, S. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2009.2013885 · Cited by 676 · cited 2×
“CEEMD was applied to EMG denoising by [104] along with an improved version of the interval thresholding (IT) method designed by [98].”
MethodSampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634 · cited 1×
“MAs that come from the change in skin– electrode interface impedance are usually in the frequency range of 0–20 Hz, while MAs that arise from the motion of the cables can be up to 50 Hz [16].”
BackgroundStandards for Reporting EMG Data*
(2000) · Measurement of Human Locomotion · doi:10.1201/9781420036985.ax2 · Cited by 626
IEEE Transactions on Neural Systems and Rehabilitation Engineering
(2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.7333 · Cited by 569
Computational and Mathematical Methods in Medicine
Jones, P., & Sivaloganathan, S. (2011) · Computational and Mathematical Methods in Medicine · doi:10.1155/2011/303089 · Cited by 527
IEEE Journal of Biomedical and Health Informatics
(2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2021.3126038 · Cited by 525
On the computational complexity of the empirical mode decomposition algorithm
Wang, Y.-H., Yeh, C.-H., Young, H.-W. V., Hu, K., & Lo, M.-T. (2014) · Physica A: Statistical Mechanics and its Applications · doi:10.1016/j.physa.2014.01.020 · Cited by 415 · cited 1×
“[117] tested the computational complexity of the EMD/EEMD and demonstrated that the result was equivalent to the Fourier transform.”
MethodProceedings IEEE International Conference on Acoustics, Speech and Signal Processing
Świętojański, P., & Renals, S. J. (2015) · Cited by 405
Drake, J. D. M., & Callaghan, J. P. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.07.003 · Cited by 399 · cited 3×
“Its frequency spectrum goes up to 100 Hz [12].”
BackgroundMethodMijović, B., De Vos, M., Gligorijević, I., Taelman, J., & Van Huffel, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2051440 · Cited by 382
Investigation into the origin of the noise of surface electrodes
Huigen, E., Peper, A., & Grimbergen, C. A. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344216 · Cited by 353 · cited 1×
“This results in a lower signal-to-noise ratio (SNR), which can also be modelled as the addition of flicker noise (1/ f ) or pink noise (1/ f n ) (Figure 2) [11].”
Background(2003) · Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439) · doi:10.1109/iembs.2003.1279435 · Cited by 337
VAN BOXTEL, A. (2001) · Psychophysiology · doi:10.1017/s004857720199016x · Cited by 292
Medical and Biological Engineering and Computing 1997-2005
Voigt, H., & Magjarević, R. (2014) · Launching IFMBE into the 21st Century: 50 Years and Counting · doi:10.1007/978-3-642-30160-5_8 · Cited by 258
Tutorial. Surface EMG detection, conditioning and pre-processing: Best practices
Merletti, R., & Cerone, G. L. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102440 · Cited by 233 · cited 4×
“Additionally, band-stop filters such as notch filters introduce a hole in the spectrum that removes not only the PLI component but also the EMG signal within this frequency band [6].”
BackgroundMethodInfluentialRemoving ECG noise from surface EMG signals using adaptive filtering
Lu, G., Brittain, J.-S., Holland, P., Yianni, J., Green, A. L., Stein, J. F., Aziz, T. Z., & Wang, S. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.063 · Cited by 222 · cited 1×
“The RLS algorithm was used by [51] and a variant of the RLS algorithm was also submitted by [52] to remove the ECG artifact.”
MethodHigh-pass filtering to remove electrocardiographic interference from torso EMG recordings
Redfern, M., Hughes, R., & Chaffin, D. (1993) · Clinical Biomechanics · doi:10.1016/s0268-0033(05)80009-9 · Cited by 209 · cited 1×
“[28] compared high-pass filters with cutoff frequencies of 10, 30 and 60 Hz in ECG removal; they advocated for the use of the 30 Hz cutoff.”
MethodEMG signal filtering based on Empirical Mode Decomposition
Andrade, A. O., Nasuto, S., Kyberd, P., Sweeney-Reed, C. M., & Van Kanijn, F. R. (2006) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2006.03.003 · Cited by 196 · cited 2×
“[7] used EMD to filter WGN from an EMG signal.”
BackgroundMethodReducing Motion Artifacts and Interference in Biopotential Recording
Webster, J. G. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325244 · Cited by 181 · cited 1×
“Ambient noise is caused by electromagnetic radiation that can arise from other equipment, such as electrical wires, televisions and radios [13].”
Background(2012) · InTech eBooks · doi:10.5772/3315 · Cited by 174 · cited 1×
“Since it originates from power lines, PLI has a frequency centered at either 50 Hz (Europe) or 60 Hz (North-America) [14].”
Background(1992) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1992.589383 · Cited by 162
Spectral analysis of human inspiratory diaphragmatic electromyograms
Schweitzer, T. W., Fitzgerald, J. W., Bowden, J. A., & Lynne-Davies, P. (1979) · Journal of Applied Physiology · doi:10.1152/jappl.1979.46.1.152 · Cited by 148 · cited 2×
“However, [27] established that the resulting square waves are more detrimental than the interference itself.”
BackgroundJournal of Clinical Monitoring and Computing
(2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/10877.1573-2614 · Cited by 134
Surface EMG data aggregation processing for intelligent prosthetic action recognition
Li, C., Li, G., Jiang, G., Chen, D., & Liu, H. (2018) · Neural Computing and Applications · doi:10.1007/s00521-018-3909-z · Cited by 132 · cited 2×
“In terms of the optimal decomposition level, level 4 appears to be the most widely used [5,19,71,77,82,85,86], while the level 3 is also frequently chosen [25,72,87–90].”
BackgroundAutomated Biosignal Quality Analysis for Electromyography Using a One-Class Support Vector Machine
Fraser, G. D., Chan, A. D. C., Green, J. R., & MacIsaac, D. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2317296 · Cited by 130 · cited 1×
“Mitigation) [8].”
The origin of skin-stretch-caused motion artifacts under electrodes
Talhouet, H. D., & Webster, J. G. (1996) · Physiological Measurement · doi:10.1088/0967-3334/17/2/003 · Cited by 124 · cited 1×
“The most common source of perturbation is body movement during recording, which can generate changes in the skin–electrode interface impedance and even give rise to fluctuations due to the motion of the cables [15].”
BackgroundMethods to reduce the variability of EMG power spectrum estimates
Baratta, R. V., Solomonow, M., Zhou, B.-H., & Zhu, M. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00031-x · Cited by 124 · cited 8×
“However, in contrast to [17], who estimated the coefficients using two regressions, they performed a frequency analysis on the reference noisy signal ( x n ( t ) ) to obtain A , f and Φ .”
BackgroundMethodInfluentialAdaptive filtering for ECG rejection from surface EMG recordings
Marque, C. K., Bisch, C., Dantas, R., Elayoubi, S., Brosse, V., & Pérot, C. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.10.001 · Cited by 123 · cited 1×
“The RLS algorithm was used by [51] and a variant of the RLS algorithm was also submitted by [52] to remove the ECG artifact.”
MethodIdentification of Contaminant Type in Surface Electromyography (EMG) Signals
McCool, P., Fraser, G. D., Chan, A. D. C., Petropoulakis, L., & Soraghan, J. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2299573 · Cited by 101 · cited 1×
“Mitigation (henceforth referred to as contamination, reduction and/or denoising) attempts to remove or reduce contaminants in the recorded biosignal [9].”
BackgroundFiltering of surface EMG using ensemble empirical mode decomposition
Zhang, X., & Zhou, P. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.10.009 · Cited by 101 · cited 2×
“According to [100], band-pass filtering allows for the reduction in the signal’s bandwidth, thus increasing the frequency resolution when the signal needs to be decomposed.”
BackgroundMethodAdaptive whitening of the electromyogram to improve amplitude estimation
Clancy, E., & Farry, K. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.844217 · Cited by 99 · cited 1×
“[24] highlighted that cutoff frequencies greater than 20 Hz may not be appropriate for fatigue analysis.”
BackgroundQuantification and solutions of arm movements effect on sEMG pattern recognition
Liu, J., Zhang, D., Sheng, X., & Zhu, X. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.05.001 · Cited by 93 · cited 1×
“Indeed, while the performance of these devices is good in controlled laboratory environments, their real-word performance is not entirely reliable due to the infinite sources of disturbance [4].”
BackgroundNeural-ICA and wavelet transform for artifacts removal in surface EMG
Azzerboni, B., Carpentieri, M., Foresta, F. L., & Morabito, F. C. (2005) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2004.1381194 · Cited by 90 · cited 1×
“[110] introduced a method combining the wavelet transform and ICA to denoise the multichannel EMG.”
MethodReal time ECG artifact removal for myoelectric prosthesis control
Zhou, P., Lock, B. A., & Kuiken, T. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/4/006 · Cited by 89 · cited 1×
“A variant of this method is to set a threshold on the amplitude of the signal and to clip the amplitude to this value if the signal goes over the previously set threshold [30,31].”
MethodEMG Signal Filtering Based on Variational Mode Decomposition and Sub-Band Thresholding
Ma, S., Lv, B., Lin, C., Sheng, X., & Zhu, X. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2987528 · Cited by 76
Deng, Y., Wolf, W., Schnell, R., & Appel, U. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867924 · Cited by 73 · cited 2×
“However, its redundancy was criticized by [56], who designed a variant of the ESAIC (ESC) that overcomes this problem.”
BackgroundOrtolan, R. L., Mori, R. N., Pereira, R. R., Cabral, C. M. N., Pereira, J. C., & Cliquet, A. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.810432 · Cited by 72 · cited 2×
“The classic ANC based on the FIR filter and the LMS algorithm were also employed by [53] to remove the power-line interference.”
MethodA Hybrid WD-EEMD sEMG Feature Extraction Technique for Lower Limb Activity Recognition
Vijayvargiya, A., Gupta, V., Kumar, R., Dey, N., & Tavares, J. M. R. S. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3095594 · Cited by 71 · cited 3×
“It is the same for [19], which uses the WT to remove the WGN and then the EEMD for the PLI and BW.”
BackgroundMethodZivanovic, M., & González‐Izal, M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.03.015 · Cited by 60 · cited 1×
“[34] extended this approach by making it adaptive over the time of the trial.”
BackgroundSurface electromyography signal denoising via EEMD and improved wavelet thresholds
Sun, Z., Xi, X., Yuan, C., Yang, Y., & Hua, X. (2020) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2020359 · Cited by 58 · cited 1×
“Another denoising algorithm based on EEMD and an improved wavelet threshold was introduced by [102] to remove random noise.”
MethodVMD-based denoising methods for surface electromyography signals
Xiao, F., Yang, D., Guo, X., & Wang, Y. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab33e4 · Cited by 58 · cited 6×
“Two EMG denoising schemes based on VMD were developed by [106].”
BackgroundMethodInfluentialZhou, P., & Kuiken, T. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/12/005 · Cited by 58
A frequency domain Hampel filter for blind rejection of sinusoidal interference from electromyograms
Allen, D. P. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.10.019 · Cited by 54 · cited 2×
“The method proposed by [66] thus allows more than one spike to be detected at any frequency.”
MethodA Comparative Study of Wavelet Denoising of Surface Electromyographic Signals
Jiang, C., & Kuo, S.-L. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352679 · Cited by 54 · cited 2×
“These results appear to be consistent with the literature, since most studies have reported using either the db2 [73–79] or the db4 [67,80–84].”
ResultIntelligent automation and soft computing
Bălaş, V. E. (2015) · Advances in Robotics & Automation · Cited by 50
Pilkar, R. B., Yarossi, M. P., Ramanujam, A., Rajagopalan, V., Bayram, M. B., Mitchell, M., Canton, S. P., & Forrest, G. F. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2624763 · Cited by 48 · cited 1×
“EMD-based denoising methods have also been performed to remove electrical stimulation [96] and ECG [97].”
MethodImproved Prosthetic Control Based on Myoelectric Pattern Recognition via Wavelet-Based De-Noising
Maier, J., Naber, A., & Ortiz-Catalan, M. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2771273 · Cited by 47 · cited 3×
“In prosthetic control, more than any other application, it is critical to maintain a robust interpretation of the intentions of the user, and for this, a clean EMG signal appears to be a prerequisite [5].”
BackgroundMethodTaelman, J., Huffel, S. V., & Spaepen, A. J. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352382 · Cited by 45 · cited 2×
“In fact, the authors used 6 [111], 8 [113] and 18 [112] levels of decomposition.”
MethodRemoving Cardiac Artifacts From Single-Channel Respiratory Electromyograms
Petersen, E., Sauer, J., Graßhoff, J., & Rostalski, P. (2020) · IEEE Access · doi:10.1109/access.2020.2972731 · Cited by 45 · cited 4×
“These results appear to be consistent with the literature, since most studies have reported using either the db2 [73–79] or the db4 [67,80–84].”
BackgroundMethodResultInfluentialAbbaspour, S., Fallah, A., Lindén, M., & GholamHosseini, H. (2015) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2015.11.003 · Cited by 45 · cited 2×
“For example, [58] used wavelet thresholding to remove the remaining noise from its ANC.”
BackgroundMethodDenoising of surface EMG with a modified Wiener filtering approach
Aschero, G., & Gizdulich, P. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.02.003 · Cited by 42 · cited 1×
“[62] designed a comparable solution in which the background noise is acquired in real time via a separated channel.”
BackgroundWAVELET-BASED DENOISING ALGORITHM FOR ROBUST EMG PATTERN RECOGNITION
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2010) · Fluctuation and Noise Letters · doi:10.1142/s0219477511000466 · Cited by 41 · cited 1×
“The HAD function can be stated as follows: Another popular function is the soft function (SOF), which is an extension of the hard function [92].”
BackgroundXu, L., Peri, E., Vullings, R., Rabotti, C., Dijk, J. P. V., & Mischi, M. (2020) · Sensors · doi:10.3390/s20174890 · Cited by 41 · cited 1×
“Since then, many variations of this method have been reported [26,48–50].”
Methodvon Tscharner, V., Eskofier, B. M., & Federolf, P. (2011) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.03.004 · Cited by 40
Removal of ECG contamination from diaphragmatic EMG by nonlinear filtering
Liang, H., Lin, Z., & Yin, F. (2004) · Nonlinear Analysis · doi:10.1016/j.na.2004.09.018 · Cited by 39 · cited 1×
“Other nonlinear ANC using the state space were also investigated [59,60].”
MethodRemoving harmonic power line interference from biopotential signals in low cost acquisition systems
Costa, M. H., & Tavares, M. C. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.03.004 · Cited by 37 · cited 1×
“[54] presented a derived version of this procedure, adapting it to also take into account the harmonics of PLI.”
MethodWavelet De-Noising of Electromyography
Qingju, Z., & Zhizeng, L. (2006) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2006.257406 · Cited by 34
Costa, J. D., Seixas, J. M., & de Sá, A. M. F. L. M. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.09.004 · Cited by 32 · cited 1×
“[39] submitted a distinct approach in which two different moving averages are applied to the rectified signal in order to detect the QRS complex.”
MethodShin, H., Lee, C., & Lee, M. (2009) · Journal of Medical Systems · doi:10.1007/s10916-009-9289-2 · Cited by 29 · cited 1×
“An algorithm based on the discrete cosine transform (DCT), which is derived from the Fourier transform, was also explored by [64].”
MethodLiu, J., Ying, D., & Zhou, P. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.09.008 · Cited by 28
Detection of ADC clipping, quantization noise, and amplifier saturation in surface electromyography
Fraser, G. D., Chan, A. D. C., Green, J. R., & MacIsaac, D. (2012) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2012.6226629 · Cited by 27 · cited 2×
“A similar scheme was introduced by [44] to extract the ECG signal.”
MethodBeck, T. W., DeFreitas, J. M., Cramer, J. T., & Stout, J. R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/001 · Cited by 25 · cited 1×
“[32] also employed a similar approach to attenuate the PLI.”
MethodGaliana-Merino, J. J., Fernández, D. R., & Martinez-Espla, J. J. (2013) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.04.022 · Cited by 24 · cited 1×
“[33] presented an analogous method using the stationary wavelet packet transform to estimate the amplitude and phase of the noisy signal.”
MethodThreshold Parameters Selection for Empirical Mode Decomposition-Based EMG Signal Denoising
Ashraf, H., Waris, A., Gilani, S. O., Tariq, M. U., & Alquhayz, H. (2021) · Intelligent Automation & Soft Computing · doi:10.32604/iasc.2021.014765 · Cited by 23 · cited 1×
“Other thresholding methods for EMD denoising were also studied by [99].”
MethodMarker, R. J., & Maluf, K. S. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2014.08.003 · Cited by 21 · cited 2×
“Yet, the advantage of these last two methods over a simple high-pass filter is that the detection of the QRS complex allows users to either change the filter’s cutoff frequency [44] or totally ignore the filter when it is not necessary [45].”
BackgroundXi, X., Zhang, Y., Zhao, Y., She, Q., & Luo, Z. (2019) · Review of Scientific Instruments · doi:10.1063/1.5057725 · Cited by 21 · cited 1×
“CEEMD was applied to EMG denoising by [104] along with an improved version of the interval thresholding (IT) method designed by [98].”
MethodWang, H., Bi, Z.-Y., Fan, W.-J., Zhou, Y., Zhou, Y., Li, F., Wang, K., Lü, X., & Wang, Z. (2021) · IEEE Access · doi:10.1109/access.2021.3077644 · Cited by 17 · cited 1×
“In terms of the optimal decomposition level, level 4 appears to be the most widely used [5,19,71,77,82,85,86], while the level 3 is also frequently chosen [25,72,87–90].”
BackgroundBoostEMD: An Extension of EMD Method and Its Application for Denoising of EMG Signals
Damaševičius, R., Vasiljevas, M., Martišius, I., Jusas, V., Birvinskas, D., & Woźniak, M. (2015) · Elektronika ir Elektrotechnika · doi:10.5755/j01.eee.21.6.13763 · Cited by 17 · cited 1×
“A further extension of the EMD method, called BoostEMD, was designed by [105].”
MethodCorvini, G., D’Anna, C., & Conforto, S. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103420 · Cited by 15 · cited 1×
“Since these features are extracted from a frequency representation of the sEMG signal, any deformation of the spectrum due to an external cause could present a misleading picture of the fatigue state of the muscle [3].”
BackgroundKim, M., Moon, Y., Hunt, J., McKenzie, K. A., Horin, A. P., McGuire, M., Kim, K., Hargrove, L. J., & Jayaraman, A. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.660583 · Cited by 13 · cited 2×
“[61] also reproduced this procedure to reduce the contamination caused by electrical stimulation.”
BackgroundMethodThe application of Empirical Mode Decomposition in elimination of ECG contamination from EMG signals
Naji, M., Firoozabadi, M., & Kahrizi, S. (2011) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme.2011.6168590 · Cited by 12 · cited 2×
“EMD-based denoising methods have also been performed to remove electrical stimulation [96] and ECG [97].”
MethodInterference cancellation in EMG signal Using ANFIS
Kezi, C., Vijila, S., & Kumar, C. E. S. (n.d.) · Cited by 12
Comparative study of wavelet denoising in myoelectric control applications
Sharma, T., & Veer, K. (2016) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2016.1139200 · Cited by 12 · cited 2×
“In terms of the optimal decomposition level, level 4 appears to be the most widely used [5,19,71,77,82,85,86], while the level 3 is also frequently chosen [25,72,87–90].”
BackgroundMethodBaseline Adaptive Wavelet Thresholding Technique for sEMG Denoising
Bartolomeo, L. D., Zecca, M., Sessa, S., Lin, Z., Mukaeda, Y., Ishii, H., Takanishi, A., Pham, T. D., Zhou, X., Tanaka, H., et al. (2011) · AIP conference proceedings · doi:10.1063/1.3596644 · Cited by 10 · cited 2×
“[77] proposed using a quiet trial to estimate the background noise as reported with the Fourier transform.”
BackgroundMethodResearch on AR-AKF Model Denoising of the EMG Signal
Chen, S., Luo, Z., & Hua, T. (2021) · Computational and Mathematical Methods in Medicine · doi:10.1155/2021/9409560 · Cited by 10 · cited 1×
“Other nonlinear ANC using the state space were also investigated [59,60].”
MethodZivanovic, M., Niegowski, M., Lecumberri, P., & Gómez, M. (2017) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.01.008 · Cited by 8 · cited 1×
“It is described as a long-term drift that can be observed through the variation of the DC components [18].”
BackgroundA Review of Surface EMG in Clinical Rehabilitation Care Systems Design
Chan, B., Saad, I., Bolong, N., & Siew, K. E. (2021) · IEEE Student Conference on Research and Development (SCOReD) · doi:10.1109/scored53546.2021.9652736 · Cited by 7 · cited 1×
“However, inserting electrodes is an invasive procedure and implanted electrodes cause patient discomfort during muscle movement; sEMG was introduced to overcome these problems [1].”
BackgroundEnhancing classification accuracy of wrist movement by denoising sEMG signals
Abbas, B., Farooq, O., Uzzaman, Y., Khan, A. A., & Vyas, A. L. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610860 · Cited by 7
Noise Detection for Biosignals Using an Orthogonal Wavelet Packet Tree Denoising Algorithm
Schimmack, M., & Mercorelli, P. (2016) · International Journal of Electronics and Telecommunications · doi:10.1515/eletel-2016-0002 · Cited by 4
Metadata
- Authors
- Boyer, M., Bouyer, L., Roy, J.-S., & Campeau-Lecours, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2023-03-08
- Volume
- 23
- Issue
- 6
- Pages
- 2927
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W4323569095
- Cited by
- 200
- References
- 93
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.