Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds
Open accessThe DOI matches its Crossref record; 61 of the 62 references it cites were found in a registry or an index.
Abstract
This study assessed the Stryd running power meter validity at sub-maximal speeds (8 to 19 km/h). Six recreational runners performed an incremental indoor running test. Power output (PO), ground contact time (GCT) and leg spring stiffness (LSS) were compared to reference measures recorded by portable metabolic analyser, force platforms and motion capture system. A Bayesian framework was conducted for systems validity and comparisons. We observed strong and positive linear relationships between Stryd PO and oxygen consumption ( R 2 = 0.82 , B F 10 > 100 ), and between Stryd PO and external mechanical power ( R 2 = 0.88 , B F 10 > 100 ). Stryd power meter underestimated PO ( B F 10 > 100 ) whereas GCT and LSS values did not show any significant differences with the reference measures ( B F 10 = 0.008 , B F 10 = 0.007 , respectively). We conclude that the Stryd power meter provides valid measures of GCT and LSS but underestimates the absolute values of PO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 Mechanical stride changes during the MAS test. The top plots (a,b) represent changes in GCT over speed and stride frequency respectively. The bottom plots (c,d) represent changes in leg stiffness (kleg) over speed and stride frequency according to McMahon and Cheng [22]. In each figures, dots represent the group mean values, error bars the standard deviation in both x, y axes. The solid line is the regression line from the Bayesian linear model, surrounded by the 95% credible intervals.](https://figures.cochat.ai/paper-figures/01e73a6d9c1844629d06f725e2ba1430/validity-of-the-stryd-power-meter-in-measuring-running-parameters-at-submaximal-figure-2.jpg)



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The same applied to the validity and reliability of the running power meter (Stryd) for variables of contact time and leg spring stiffness during a maximal incremental test (Imbach et al., 2020).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Imbach et al., 2020
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Also, the study showed that it is a useful tool for quantifying running intensity at submaximal speeds (Imbach et al., 2020).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Imbach et al., 2020
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Random effects structure for confirmatory hypothesis testing: Keep it maximal
Barr, D. J., Levy, R., Scheepers, C., & Tily, H. J. (2013) · Journal of Memory and Language · doi:10.1016/j.jml.2012.11.001 · Cited by 10,328 · cited 1×
“Through a design-driven approach [35], subject varying intercept and slopes were included in addition to fixed effects.”
Methodbrms : An R Package for Bayesian Multilevel Models Using Stan
Bürkner, P.-C. (2017) · Journal of Statistical Software · doi:10.18637/jss.v080.i01 · Cited by 9,476 · cited 1×
“Bayes factors were estimated through a bridge sampling and using the R package “brms” [39].”
MethodVehtari, A., Gelman, A., Simpson, D., Carpenter, B., & Bürkner, P.-C. (2021) · Bayesian Analysis · doi:10.1214/20-ba1221 · Cited by 1,810 · cited 1×
“The Hamilton Monte Carlo algorithm was used to infer the parameters of models and caution has been taken to diagnose their convergence [32].”
MethodBayesian Cognitive Modeling: A Practical Course
Lee, M. D., & Wagenmakers, E.-J. (2014) · doi:10.1017/cbo9781139087759 · Cited by 1,795
The spring-mass model for running and hopping
Blickhan, R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90224-8 · Cited by 1,673
The mechanics of running: How does stiffness couple with speed?
McMahon, T. A., & Cheng, G. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90042-2 · Cited by 1,121
Leg stiffness and stride frequency in human running
Farley, C. T., & González, O. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00029-1 · Cited by 737
Mechanical work and efficiency in level walking and running
Cavagna, G. A., & Kaneko, M. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011866 · Cited by 664
The Slow Component of Oxygen Uptake Kinetics in Humans
GAESSER, G. A., & POOLE, D. C. (1996) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-199600240-00004 · Cited by 663
Research works printed but not linked: 2
- Smith S. Digital Signal Processing: A Practical Guide for Engineers and Scientists Elsevier Burlington, MA, USA 2013
- Jeffreys H. Theory of Probability Oxford Univ. Press Oxford, UK 1961
Cited by
Wearables for Running Gait Analysis: A Systematic Review
Mason, R., Pearson, L. T., Barry, G., Young, F., Lennon, O., Godfrey, A., & Stuart, S. (2022) · Sports Medicine · doi:10.1007/s40279-022-01760-6 · Cited by 196
Migliaccio, G. M., Padulo, J., & Russo, L. (2024) · Applied Sciences · doi:10.3390/app14156649 · Cited by 95
Ruiz‐Alias, S. A., Olaya-Cuartero, J., Ñancupil‐Andrade, A. A., & García‐Pinillos, F. (2022) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2022-0069 · Cited by 53
Training Monitoring in Sports: It Is Time to Embrace Cognitive Demand
Perrey, S. (2022) · Sports · doi:10.3390/sports10040056 · Cited by 52
Self-citationRunning power: lab based vs . portable devices measurements and its relationship with aerobic power
Taboga, P., Giovanelli, N., Spinazzè, E., Cuzzolin, F., Fedele, G., Zanuso, S., & Lazzer, S. (2021) · European Journal of Sport Science · doi:10.1080/17461391.2021.1966104 · Cited by 42
Leg Stiffness, Joint Stiffness, and Running-Related Injury: Evidence From a Prospective Cohort Study
Davis, J. J., & Gruber, A. H. (2021) · Orthopaedic Journal of Sports Medicine · doi:10.1177/23259671211011213 · Cited by 31
Is Stryd critical power a meaningful parameter for runners?
Dearing, C. G., & Paton, C. D. (2022) · Biology of Sport · doi:10.5114/biolsport.2023.118025 · Cited by 26
Perrotin, N., Gardan, N., Lesprillier, A., Goff, C. L., Seigneur, J.-M., Abdi, E., Sañudo, B., & Taïar, R. (2021) · Applied Sciences · doi:10.3390/app11052093 · Cited by 24
Validation of the RunScribe inertial measurement unit for walking gait measurement
Lewin, M., Price, C., & Nester, C. (2022) · PLoS ONE · doi:10.1371/journal.pone.0273308 · Cited by 21
Running Critical Power: A Comparison Of Different Theoretical Models
Ruiz‐Alias, S. A., Ñancupil‐Andrade, A. A., Pérez‐Castilla, A., & García‐Pinillos, F. (2023) · International Journal of Sports Medicine · doi:10.1055/a-2069-2192 · Cited by 19
van Rassel, C. R., Ajayi, O. O., Sales, K. M., Griffiths, J. K., Fletcher, J. R., Edwards, W. B., & MacInnis, M. J. (2023) · Sensors · doi:10.3390/s23218729 · Cited by 19
Reliability and validity of the Stryd Power Meter during different walking conditions
Jauregi, A. P., García-Tabar, I., Carrier, B., Navalta, J. W., & Cámara, J. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.11.041 · Cited by 18
Rodríguez‐Barbero, S., González‐Mohíno, F., González‐Ravé, J. M., Rodrigo‐Carranza, V., & Santos‐García, D. J. (2024) · Sports Biomechanics · doi:10.1080/14763141.2023.2298960 · Cited by 17
Running Critical Power and W´: Influence of the Environment, Timing and Time Trial Order
Ruiz‐Alias, S. A., Ñancupil‐Andrade, A. A., Pérez‐Castilla, A., & García‐Pinillos, F. (2023) · International Journal of Sports Medicine · doi:10.1055/a-2201-7081 · Cited by 17
Influence of the World Athletics Stack Height Regulation on Track Running Performance
Ruiz‐Alias, S. A., Pérez‐Castilla, A., Soto-Hermoso, V. M., & García‐Pinillos, F. (2023) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004523 · Cited by 15
Clustering Runners’ Response to Different Midsole Stack Heights: A Field Study
Kögel, J., Huerta, S., Gambietz, M., Ullrich, M., Heyde, C., Dorschky, E., & Eskofier, B. M. (2024) · Sensors · doi:10.3390/s24144694 · Cited by 14
Ruiz‐Alias, S. A., Ñancupil‐Andrade, A. A., Pérez‐Castilla, A., & García‐Pinillos, F. (2023) · European Journal of Applied Physiology · doi:10.1007/s00421-023-05243-y · Cited by 14
Berzosa, C., Comeras-Chueca, C., Bascuas, P. J., Gutiérrez, H., & Bataller-Cervero, A. V. (2024) · Sensors · doi:10.3390/s24113570 · Cited by 14
Barrett, A. M. S., & Maunder, E. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05792-4 · Cited by 12
Ruiz‐Alias, S. A., Ñancupil‐Andrade, A. A., Pérez‐Castilla, A., & García‐Pinillos, F. (2023) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371231200295 · Cited by 12
Uddin, M. Z., Seeberg, T. M., Kocbach, J., Liverud, A. E., Gonzalez-Sanchez, V. E., Sandbakk, Ø. B., & Meyer, F. (2021) · Sensors · doi:10.3390/s21196500 · Cited by 12
Davis, J. J., Meardon, S. A., Brown, A. W., Raglin, J. S., Harezlak, J., & Gruber, A. H. (2024) · Sensors · doi:10.3390/s24092892 · Cited by 11
Rodríguez‐Barbero, S., González‐Ravé, J. M., Vanwanseele, B., Santos‐García, D. J., de la Cruz, V. M., & González‐Mohíno, F. (2025) · Applied Sciences · doi:10.3390/app15020903 · Cited by 11
Prediction of Half-Marathon Power Target using the 9/3-Minute Running Critical Power Test
Olaya-Cuartero, J., Pueo, B., Villalón-Gasch, L., & Jiménez-Olmedo, J. M. (2023) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2023.526 · Cited by 10
Stryd biomechanical parameters as indicators of running economy and performance
Jaén‐Carrillo, D., Ruiz‐Alias, S. A., Olaya-Cuartero, J., & García‐Pinillos, F. (2024) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/17543371231220760 · Cited by 10
Ruiz‐Alias, S. A., Ñancupil‐Andrade, A. A., Pérez‐Castilla, A., & García‐Pinillos, F. (2023) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004609 · Cited by 10
Jaén‐Carrillo, D., Ruiz‐Alias, S. A., & García‐Pinillos, F. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05840-z · Cited by 9
Brewer, M. A., Morrow, N. S. J., Peng, X., Obajemu, O., Boyer, K. E., & Gilbert, J. E. (2025) · Annual Conference on Human-Computer Interaction and Sports (SportsHCI) · doi:10.1145/3749385.3749389 · Cited by 9
Gabrecht, M. T., Wang, H., & Matthies, D. J. C. (2023) · International Workshop on Sensor-based Activity Recognition and Interaction (iWOAR) · doi:10.1145/3615834.3615853 · Cited by 9
Running critical power: between-day, interlimb and interunit reliability
Ruiz‐Alias, S. A., Ñancupil‐Andrade, A. A., Pérez‐Castilla, A., & García‐Pinillos, F. (2024) · Sports Engineering · doi:10.1007/s12283-024-00452-w · Cited by 9
Ruiz‐Alias, S. A., Pérez‐Castilla, A., Soto-Hermoso, V. M., & García‐Pinillos, F. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1979-5849 · Cited by 9
Osmani, F., Lago-Fuentes, C., Alemany-Iturriaga, J., & Barcala-Furelos, M. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1155037 · Cited by 8
“In addition, SmO2 also did not present correlations with variables such as power (W) and RPE, as these variables were previously validated for maximal incremental efforts (Haddad et al., 2017; Imbach et al., 2020).”
BackgroundMethodDurability of physiological and biomechanical variables during a marathon
Hunter, B., Lena, A., & Muniz‐Pumares, D. (2025) · Journal of Sports Sciences · doi:10.1080/02640414.2025.2567780 · Cited by 7
Alda-Blanco, A., Rodríguez‐Barbero, S., Rodrigo‐Carranza, V., Valero, F., Chico, P., & González‐Mohíno, F. (2024) · Sports · doi:10.3390/sports12120329 · Cited by 7
Mechanical Running Power and Energy Expenditure in Uphill and Downhill Running
Gravina-Cognetti, F., Chaverri, D., Planas, A., Montraveta, J., Carrasco‐Marginet, M., Puigarnau, S., Espasa-Labrador, J., & Iglesias, X. (2025) · Sports · doi:10.3390/sports13090294 · Cited by 7
Does Power Output at Critical Power Intensity Interchange between Cycling and Running?
Olaya-Cuartero, J., Pueo, B., Penichet-Tomás, A., & Villalón-Gasch, L. (2023) · Applied Sciences · doi:10.3390/app13095511 · Cited by 7
Validity and Reliability of the VmaxPro IMU for back squat exercise in multipower machine
Olaya-Cuartero, J., Villalón-Gasch, L., Penichet-Tomás, A., & Jiménez-Olmedo, J. M. (2022) · Journal of Physical Education and Sport · doi:10.7752/jpes.2022.11369 · Cited by 7
Genitrini, M., Fritz, J., STÖGGL, T. L., & Schwameder, H. (2023) · Sports · doi:10.3390/sports11100188 · Cited by 7
Running Economy in the Vertical Kilometer
Bascuas, P. J., Gutiérrez, H., Piedrafita, E., Rabal-Pelay, J., Berzosa, C., & Bataller-Cervero, A. V. (2023) · Sensors · doi:10.3390/s23239349 · Cited by 7
Running work capacity over critical power: a variable rather than a constant parameter
Ruiz‐Alias, S. A., Ñancupil‐Andrade, A. A., Pérez‐Castilla, A., & García‐Pinillos, F. (2024) · Sports Engineering · doi:10.1007/s12283-024-00454-8 · Cited by 6
Dewanti, R. A., & Hermawan, I. (2022) · Journal of Physical Education and Sport · doi:10.7752/jpes.2022.12390 · Cited by 6
Hingrand, C., Olivier, N., Combes, A., Bensaid, S., & Daussin, F. (2023) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004598 · Cited by 6
Olaya-Cuartero, J., Plaza-Morales, D., Jiménez-Olmedo, J. M., & Lipińska, P. (2023) · Journal of Physical Education and Sport · doi:10.7752/jpes.2023.09274 · Cited by 6
Power or speed: Which metric is more accurate for modelling endurance running performance on track?
Ruiz‐Alias, S. A., Ñancupil‐Andrade, A. A., Pérez‐Castilla, A., & García‐Pinillos, F. (2024) · European Journal of Sport Science · doi:10.1002/ejsc.12210 · Cited by 5
Acute effects of interval training on running kinematics in runners: A systematic review
Rodríguez‐Barbero, S., González‐Mohíno, F., Rodrigo‐Carranza, V., Santos‐García, D. J., Boullosa, D. A., & González‐Ravé, J. M. (2023) · Gait & Posture · doi:10.1016/j.gaitpost.2023.04.009 · Cited by 5
Reliability and Validity of the SHFT Running Power Meter
Linkis, J. E., Bonne, T. C., Bejder, J., Rasmussen, E. K., Andersen, A. B., & Nordsborg, N. B. (2021) · Sensors · doi:10.3390/s21227516 · Cited by 5
Grand challenges in physical neuroergonomics
Perrey, S. (2023) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2023.1137854 · Cited by 4
Self-citationPrediction of Half-Marathon Power Target using the 9/3-Minute Running Critical Power Test
Olaya-Cuartero, J., Pueo, B., Villalón-Gasch, L., & Jiménez-Olmedo, J. M. (2023) · Journal of Sports Science and Medicine · doi:10.52082/jssm.2023.525 · Cited by 4
Running Functional Threshold versus Critical Power: Same Concept but Different Values
Ñancupil‐Andrade, A. A., Ruiz‐Alias, S. A., Pérez‐Castilla, A., Jaén‐Carrillo, D., & García‐Pinillos, F. (2023) · International Journal of Sports Medicine · doi:10.1055/a-2155-6813 · Cited by 4
Jauregi, A. P., & Ozaeta-Beaskoetxea, E. (2025) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000005207 · Cited by 3
Jaén‐Carrillo, D., Bruce, C. D., Gobbo, C., Howe, C. A., & Lawley, J. S. (2026) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2025-0607 · Cited by 3
Foot Pod Technology and Their Utility for Change of Direction Testing: A Technological Review
Albarrán, E. J., & CRONIN, J. W. (2025) · Strength and conditioning journal · doi:10.1519/ssc.0000000000000901 · Cited by 2
Validity of Stryd Running Power for Estimating Metabolic Demand During Incline Treadmill Running
van Rassel, C. R., Gow, S., Watanabe, T., Jaén‐Carrillo, D., & MacInnis, M. J. (2026) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2025-0382 · Cited by 2
Jaén‐Carrillo, D., Bruce, C. D., Lawley, J. S., & Zanini, M. (2026) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.70299 · Cited by 2
Hudgins, J. H., Pastina, J. T., Gillis, I. L., Abel, M. G., Bergstrom, H. C., Black, W. S., & Best, S. A. (2024) · Journal of Sports Sciences · doi:10.1080/02640414.2024.2426903 · Cited by 2
Jaén‐Carrillo, D., Lawley, J. S., Rubio-Peirotén, A., & Cartón-Llorente, A. (2025) · International Journal of Sports Science & Coaching · doi:10.1177/17479541251345777 · Cited by 2
Alda-Blanco, A., González‐Mohíno, F., González‐Ravé, J. M., & Santos‐Concejero, J. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1653896 · Cited by 2
The Stryd Foot Pod Is a Valid Measure of Stepping Cadence During Treadmill Walking and Running
Shivgulam, M. E., Petterson, J. L., Pellerine, L. P., Kimmerly, D. S., & O'Brien, M. W. (2023) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2022-0031 · Cited by 2
Estimation of horizontal running power using foot-worn inertial measurement units
Apte, S., Falbriard, M., Meyer, F., Millet, G. P., Grémeaux, V., & Aminian, K. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1167816 · Cited by 2
Short, T., Stickley, C., Freemyer, B. G., Takata, A., & Yamada, P. M. (2024) · International journal of exercise science · doi:10.70252/uutg9352 · Cited by 1
Ruiz‐Alias, S. A., Marcos‐Blanco, A., Fernández‐Navarrete, I., Pérez‐Castilla, A., & García‐Pinillos, F. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.12254 · Cited by 1
Gabrecht, M. T., Huang, C., Matthies, D. J. C., & Jetter, H.-C. (2025) · International Conference on PErvasive Technologies Related to Assistive Environments (PETRA) · doi:10.1145/3733155.3733202 · Cited by 1
Jaén‐Carrillo, D., Cartón-Llorente, A., García‐Ramos, A., & Santos, L. (2026) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000005402 · Cited by 1
Jaén‐Carrillo, D., & Cartón-Llorente, A. (2026) · Sensors · doi:10.3390/s26103244 · Cited by 1
Short, T., & Yamada, P. M. (2024) · International journal of exercise science · doi:10.70252/ythn9269 · Cited by 1
Karparova, I., & Dimitrov, D. (2023) · RESEARCH IN KINESIOLOGY · doi:10.46705/rik2351106k · Cited by 1
Smith, S. (2021) · Liverpool John Moores University · doi:10.24377/ljmu.t.00014975
A tecnologia como auxílio no treinamento de corrida e triathlon
Pinto, R. D. F. P. (2024) · doi:10.47749/t/unicamp.2024.1408546
Running critical power modeling: insights into physiological and neuromuscular performance factors
Ruiz‐Alias, S. A., Marcos‐Blanco, A., Fernández‐Navarrete, I., Pérez‐Castilla, A., & García‐Pinillos, F. (2025) · International Journal of Sports Medicine · doi:10.1055/a-2558-6349
Wearable Assessment of Level and Uphill Running at Critical IntensityPreprint
Kirner, N., & Hoogkamer, W. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.04.25.650654
The influence of menstrual cycle in heart rate variability and performance
Barría-Miranda, F., Azócar-Gallardo, J., Ñancupil-Andrade, L., Ñancupil‐Andrade, A. A., García-Carrillo, E., Campos-Uribe, V., & Barria, M. A. C. (2025) · Journal of Human Sport and Exercise · doi:10.55860/zetvkm28
Novel Wearable Technology Methods to Guide and Monitor Endurance Training
van Rassel, C. R. (2025) · doi:10.11575/prism/49133
Ñancupil‐Andrade, A. A. (2023) · Institutional Repository of the University of Granada (University of Granada)
Exploring the Efficacy of Exercise Interventions To Improve Phase Angle
Short, T. (2023) · ScholarSpace (University of Hawaii at Manoa)
Ruiz‐Alias, S. A. (2024) · Institutional Repository of the University of Granada (University of Granada)
Jaén‐Carrillo, D., Rubio-Peirotén, A., Santos, L., & Cartón-Llorente, A. (2026) · German Journal of Exercise and Sport Research · doi:10.1007/s12662-026-01092-x
The Influence of Endurance Training on the Relationship Between Running Power and Oxygen Consumption
Alda-Blanco, A., Rodríguez‐Barbero, S., Salinero, J. J., & González‐Mohíno, F. (2026) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2025-0464
Rodríguez-Medina, J. (2025) · Buleria (Universidad de León) · doi:10.18002/10612/27428
Modelling responses to training loads to lead performance in sports
Imbach, F. (2021) · theses.fr (ABES) · doi:10.70675/3bb43f7bz5dd5z4fb2za648z46fc3e18be7e
Self-citationRistanović, L. (2024) · National Repository of Dissertations in Serbia
Hanka, H., & Kankaanrinne, E. (2026) · Theseus (Ammattikorkeakoulujen)
Alda-Blanco, A., Salinero, J. J., Rodríguez‐Barbero, S., Valero, F., & González‐Mohíno, F. (2026) · Applied Sciences · doi:10.3390/app16115526
Sirakov, I. (2026) · Journal of Physical Education and Sport · doi:10.7752/jpes.2026.05097
Olaya-Cuartero, J. (2026) · European journal of human movement · doi:10.21134/eurjhm.2026.56.7
Hamilton, K. C., Harden, J. E., & Rein, K. P. (2026) · Current Research in Physiology · doi:10.1016/j.crphys.2026.100189
Intensity monitoring in endurance sports: Technology matters but remember the brainPreprint
Seiler-Viken, S. A., Mentzoni, F., Seiler, S., Skarli, S., & Losnegard, T. (2026) · Research Square · doi:10.21203/rs.3.rs-10698806/v1
Cartón-Llorente, A., García‐Pinillos, F., & Jaén‐Carrillo, D. (2026) · European Journal of Sport Science · doi:10.1002/ejsc.70275
Gélinas, O. (2026) · Le dépôt institutionnel (Université du Québec à Trois-Rivières)
Metadata
- Authors
- Imbach, F., Candau, R., Chailan, R., & Perrey, S.
- Affiliations
- Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement (FR)
- Seenovate, 34000 Montpellier, France
- EuroMov Digital Health in Motion, Univ Montpellier, IMT Mines Ales, 34090 Montpellier, France
- Corresponding author
- Imbach, Frank
- Venue
- Sports
- Publisher
- MDPI AG
- Published
- 2020-07-20
- Volume
- 8
- Issue
- 7
- Pages
- 103
- ISSN
- 2075-4663 (ISSN-L)
- PMC
- PMC7404478
- OpenAlex
- W3044114303
- Semantic Scholar
- 21955b969d00ca81f6463bcdd8a5573ef84e39d9
- Cited by
- 72
- References
- 62
- Citations by year
- 2026: 9 · 2025: 14 · 2024: 13 · 2023: 21 · 2022: 8 · 2021: 7
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Association Nationale de la Recherche et de la Technologie (2018/0653)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- running power, ground contact time, oxygen consumption, incremental running test, recreational runners
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.