Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds
Open accessThe DOI matches its Crossref record; 61 of the 62 references it cites were found in a registry or an index.
Abstract
This study assessed the Stryd running power meter validity at sub-maximal speeds (8 to 19 km/h). Six recreational runners performed an incremental indoor running test. Power output (PO), ground contact time (GCT) and leg spring stiffness (LSS) were compared to reference measures recorded by portable metabolic analyser, force platforms and motion capture system. A Bayesian framework was conducted for systems validity and comparisons. We observed strong and positive linear relationships between Stryd PO and oxygen consumption ( R 2 = 0.82 , B F 10 > 100 ), and between Stryd PO and external mechanical power ( R 2 = 0.88 , B F 10 > 100 ). Stryd power meter underestimated PO ( B F 10 > 100 ) whereas GCT and LSS values did not show any significant differences with the reference measures ( B F 10 = 0.008 , B F 10 = 0.007 , respectively). We conclude that the Stryd power meter provides valid measures of GCT and LSS but underestimates the absolute values of PO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 Mechanical stride changes during the MAS test. The top plots (a,b) represent changes in GCT over speed and stride frequency respectively. The bottom plots (c,d) represent changes in leg stiffness (kleg) over speed and stride frequency according to McMahon and Cheng [22]. In each figures, dots represent the group mean values, error bars the standard deviation in both x, y axes. The solid line is the regression line from the Bayesian linear model, surrounded by the 95% credible intervals.](https://figures.cochat.ai/paper-figures/01e73a6d9c1844629d06f725e2ba1430/validity-of-the-stryd-power-meter-in-measuring-running-parameters-at-submaximal-figure-2.jpg)



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The same applied to the validity and reliability of the running power meter (Stryd) for variables of contact time and leg spring stiffness during a maximal incremental test (Imbach et al., 2020).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Imbach et al., 2020
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Also, the study showed that it is a useful tool for quantifying running intensity at submaximal speeds (Imbach et al., 2020).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Imbach et al., 2020
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Random effects structure for confirmatory hypothesis testing: Keep it maximal
Barr, D. J., Levy, R., Scheepers, C., & Tily, H. J. (2013) · Journal of Memory and Language · doi:10.1016/j.jml.2012.11.001 · Cited by 10,328 · cited 1×
“Through a design-driven approach [35], subject varying intercept and slopes were included in addition to fixed effects.”
Methodbrms : An R Package for Bayesian Multilevel Models Using Stan
Bürkner, P.-C. (2017) · Journal of Statistical Software · doi:10.18637/jss.v080.i01 · Cited by 9,476 · cited 1×
“Bayes factors were estimated through a bridge sampling and using the R package “brms” [39].”
MethodVehtari, A., Gelman, A., Simpson, D., Carpenter, B., & Bürkner, P.-C. (2021) · Bayesian Analysis · doi:10.1214/20-ba1221 · Cited by 1,810 · cited 1×
“The Hamilton Monte Carlo algorithm was used to infer the parameters of models and caution has been taken to diagnose their convergence [32].”
MethodBayesian Cognitive Modeling: A Practical Course
Lee, M. D., & Wagenmakers, E.-J. (2014) · doi:10.1017/cbo9781139087759 · Cited by 1,795
The spring-mass model for running and hopping
Blickhan, R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90224-8 · Cited by 1,673
The mechanics of running: How does stiffness couple with speed?
McMahon, T. A., & Cheng, G. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90042-2 · Cited by 1,121
Leg stiffness and stride frequency in human running
Farley, C. T., & González, O. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00029-1 · Cited by 737
Mechanical work and efficiency in level walking and running
Cavagna, G. A., & Kaneko, M. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011866 · Cited by 664
The Slow Component of Oxygen Uptake Kinetics in Humans
GAESSER, G. A., & POOLE, D. C. (1996) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-199600240-00004 · Cited by 663
Cavagna, G. A. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.39.1.174 · Cited by 624
Livesey, G., & Elia, M. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.4.608 · Cited by 581
Storage of Elastic Energy in Skeletal Muscles in Man
Asmussen, E., & Bonde‐Petersen, F. (1974) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1974.tb05693.x · Cited by 472
The effect of speed on leg stiffness and joint kinetics in human running
Arampatzis, A., Brüggemann, G.-P., & Metzler, V. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00133-5 · Cited by 435
External, Internal and Total Work in Human Locomotion
Willems, P. A., Cavagna, G. A., & Heglund, N. C. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.2.379 · Cited by 405
Moore, I. S. (2016) · Sports Medicine · doi:10.1007/s40279-016-0474-4 · Cited by 379
A Simple Method for Measuring Stiffness during Running
Morin, J.-B., Dalleau, G., Kyröläinen, H., Jeannin, T., & Belli, A. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.167 · Cited by 376
The energetics of endurance running
di Prampero, P. E., Atchou, G., Brückner, J. C., & Moia, C. (1986) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf02343797 · Cited by 375
Leg power and hopping stiffness: relationship with sprint running performance
CHELLY, S. M., & DENIS, C. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200102000-00024 · Cited by 365
Buist, I., Bredeweg, S. W., Bessem, B., van Mechelen, W., Lemmink, K. A. P. M., & Diercks, R. L. (2010) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.044677 · Cited by 258
Accuracy and reliability of a Cosmed K4b2 portable gas analysis system
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P. (2004) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(04)80039-2 · Cited by 246
Mathematical analysis of running performance and world running records
Peronnet, F., & Thibault, G. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.1.453 · Cited by 246
Running Economy: The Forgotten Factor in Elite Performance
Foster, C., & Lucia, A. (2007) · Sports Medicine · doi:10.2165/00007256-200737040-00011 · Cited by 232
Effects of altered stride frequency and contact time on leg-spring behavior in human running
Morin, J. B., Samozino, P., Zameziati, K., & Belli, A. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.001 · Cited by 224
Portable Global Positioning Units to Complement Accelerometry-Based Physical Activity Monitors
RODRÍGUEZ, D. A., BROWN, A. L., & TROPED, P. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185297.72328.ce · Cited by 218
Accuracy of SRM and Power Tap Power Monitoring Systems for Bicycling
GARDNER, A. S., STEPHENS, S., MARTIN, D. T., LAWTON, E., LEE, H., & JENKINS, D. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000132380.21785.03 · Cited by 183
Assessment of Speed and Position during Human Locomotion Using Nondifferential GPS
TOWNSHEND, A. D., WORRINGHAM, C. J., & STEWART, I. B. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181590bc2 · Cited by 178
Paton, C. D., & Hopkins, W. G. (2001) · Sports Medicine · doi:10.2165/00007256-200131070-00004 · Cited by 178
Energy cost and running mechanics during a treadmill run to voluntary exhaustion in humans
Candau, R. B., Belli, A., Millet, G. Y., Dalleau, G., Barbier, B., & Rouillon, J. D. (1998) · European Journal of Applied Physiology · doi:10.1007/s004210050363 · Cited by 173
Self-citationVO2 slow component: physiological and functional significance.
Poole, D. C., Barstow, T. J., Gaesser, G. A., Willis, W. T., & Whipp, B. J. (1994) · PubMed · Cited by 162
Paton, C. D., & Hopkins, W. G. (2002) · Sports Medicine · doi:10.2165/00007256-200232140-00006 · Cited by 126
Influence of Step Rate on Shin Injury and Anterior Knee Pain in High School Runners
Luedke, L. E., Heiderscheit, B. C., Williams, D. S. B., & Rauh, M. J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000890 · Cited by 114
García‐Pinillos, F., Roche-Seruendo, L. E., Marcén-Cinca, N., Marco-Contreras, L. A., & Román, P. Á. L. (2018) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002595 · Cited by 111
The dynamic calibration of bicycle power measuring cranks
Jones, S., & Passfield, L. (1998) · Kent Academic Repository (University of Kent) · Cited by 109
The Record Power Profile to Assess Performance in Elite Cyclists
Pinot, J., & Grappe, F. (2011) · International Journal of Sports Medicine · doi:10.1055/s-0031-1279773 · Cited by 109
Effect of Protocol on Determination of Velocity at V̇O2max and on its Time to Exhaustion
Billat, V. L., Hill, D. W., Pinoteau, J., Petit, B., & Koralsztein, J.-P. (1996) · Archives of Physiology and Biochemistry · doi:10.1076/apab.104.3.313.12908 · Cited by 100
Keir, D. A., Murias, J. M., Paterson, D. H., & Kowalchuk, J. M. (2014) · Experimental Physiology · doi:10.1113/expphysiol.2014.080812 · Cited by 97
Validity and Reliability of a Commercial Fitness Watch for Measuring Running Dynamics
Adams, D. J., Pozzi, F., Carroll, A., Rombach, A., & Zeni, J. (2016) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2016.6391 · Cited by 90
Mechanical efficiency of positive work in running at different speeds
ITO, A., KOMI, P. V., SJÖDIN, B., BOSCO, C., & KARLSSON, J. (1983) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198315040-00009 · Cited by 79
Changes in Spring-Mass Model Parameters and Energy Cost During Track Running to Exhaustion
SLAWINSKI, J. S., Heubert, R., Quièvre, J., Billat, V. L., & Hannon, C. (2008) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31816a4475 · Cited by 66
Validity of sports watches when estimating energy expenditure during running
Roos, L., Taube, W., Beeler, N., & Wyss, T. (2017) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-017-0089-6 · Cited by 54
Reliability of Trail Walking and Running Tasks Using the Stryd Power Meter
Navalta, J. W., Montes, J., Bodell, N. G., Aguilar, C. D., Radzak, K. N., Manning, J. W., & DeBeliso, M. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4068 · Cited by 54
An Assessment of Running Power as a Training Metric for Elite and Recreational Runners
Aubry, R. L., Power, G. A., & Burr, J. F. (2018) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002650 · Cited by 52
The Relationship between Running Power and Running Economy in Well-Trained Distance Runners
Austin, C., Hokanson, J. F., McGinnis, P. M., & Patrick, S. (2018) · Sports · doi:10.3390/sports6040142 · Cited by 50
García‐Pinillos, F., Román, P. Á. L., Roche-Seruendo, L. E., & García‐Ramos, A. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.11.037 · Cited by 50
Field Testing of in Cross-Country Skiers With Portable Breath-by-Breath System
Doyon, K. H., Perrey, S., Abe, D., & Hughson, R. L. (2001) · Canadian Journal of Applied Physiology · doi:10.1139/h01-001 · Cited by 46
Self-citationMechanical efficiency in athletes during running
Kyröläinen, H., Komi, P. V., & Belli, A. (1995) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.1995.tb00036.x · Cited by 45
Accuracy and Repeatability of the Polar®RS800sd to Evaluate Stride Rate and Running Speed
Hausswirth, C., Meur, Y. L., Couturier, A., Bernard, T., & Brisswalter, J. (2009) · International Journal of Sports Medicine · doi:10.1055/s-0028-1105936 · Cited by 43
Training to Maximize Economy of Motion in Running Gait
McCann, D. J., & Higginson, B. K. (2008) · Current Sports Medicine Reports · doi:10.1097/01.csmr.0000319711.63793.84 · Cited by 34
The mechanical efficiencies of running and bicycling against a horizontal impeding force
Zacks, R. M. (1973) · European Journal of Applied Physiology · doi:10.1007/bf00693710 · Cited by 29
Brisswalter, J., & Tartaruga, M. P. (2014) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2014.930711 · Cited by 22
Global Positioning System Watches for Estimating Energy Expenditure
Hongu, N. K., Orr, B. J., Roe, D. J., Reed, R. G., & Going, S. B. (2013) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31828bae0f · Cited by 21
Improved Performance in National-Level Runners With Increased Training Load at 1600 and 1800 m
Sharma, A. P., Saunders, P. U., Garvican‐Lewis, L. A., Clark, B., Welvaert, M., Gore, C. J., & Thompson, K. (2018) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2018-0104 · Cited by 19
Wearable Device Validity in Determining Step Count During Hiking and Trail Running
Navalta, J. W., Montes, J., Bodell, N. G., Aguilar, C. D., Lujan, A., Guzman, G., Kam, B. K., Manning, J. W., & DeBeliso, M. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0010 · Cited by 17
THE EFFECTS OF RUNNING SPEED ON THE METABOLIC AND MECHANICAL ENERGY COSTS OF RUNNING
Harris, C., DeBeliso, M., & Adams, K. J. (2003) · Cited by 14
Mechanical Determinants of the U-Shaped Speed-Energy Cost of Running Relationship
Carrard, A., Fontana, E., & Malatesta, D. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01790 · Cited by 14
Snyder, K. L., Mohrman, W., Williamson, J. A., & Li, K. (2018) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002894 · Cited by 11
Validade e reprodutibilidade de receptores para o GPS em relação à distância percorrida
Moreira, A., Costa, E. C., Lodo, L., Freitas, C. G., de Arruda, A. F. S., & Aoki, M. S. (2013) · Revista Andaluza de Medicina del Deporte · doi:10.1016/s1888-7546(13)70050-9 · Cited by 5
Lara, F., Shearer, L., Coppi, M. J., Hayden, N., Ogden, J. T., Murr, S., Hutchison, R. E., & Sobolewski, E. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000536517.64053.d9 · Cited by 4
Time Course of Oxygen Uptake at Exercise
phane, P. S. E. (2010) · Biomedical and health research · doi:10.3233/978-1-60750-497-9-285 · Cited by 4
Differences In Wearable Running Power On Three Different Surfaces During Submaximal Running
Coppi, M. J., Shearer, L., Hayden, N., Ogden, J. T., Lara, F., Murr, S., Sobolewski, E. J., & Hutchison, R. E. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000536519.02172.dc · Cited by 2
Research works printed but not linked: 2
- Smith S. Digital Signal Processing: A Practical Guide for Engineers and Scientists Elsevier Burlington, MA, USA 2013
- Jeffreys H. Theory of Probability Oxford Univ. Press Oxford, UK 1961
Cited by
Wearables for Running Gait Analysis: A Systematic Review
Mason, R., Pearson, L. T., Barry, G., Young, F., Lennon, O., Godfrey, A., & Stuart, S. (2022) · Sports Medicine · doi:10.1007/s40279-022-01760-6 · Cited by 196
Migliaccio, G. M., Padulo, J., & Russo, L. (2024) · Applied Sciences · doi:10.3390/app14156649 · Cited by 95
Ruiz‐Alias, S. A., Olaya-Cuartero, J., Ñancupil‐Andrade, A. A., & García‐Pinillos, F. (2022) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2022-0069 · Cited by 53
Training Monitoring in Sports: It Is Time to Embrace Cognitive Demand
Perrey, S. (2022) · Sports · doi:10.3390/sports10040056 · Cited by 52
Self-citationRunning power: lab based vs . portable devices measurements and its relationship with aerobic power
Taboga, P., Giovanelli, N., Spinazzè, E., Cuzzolin, F., Fedele, G., Zanuso, S., & Lazzer, S. (2021) · European Journal of Sport Science · doi:10.1080/17461391.2021.1966104 · Cited by 42
Metadata
- Authors
- Imbach, F., Candau, R., Chailan, R., & Perrey, S.
- Affiliations
- Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement (FR)
- Seenovate, 34000 Montpellier, France
- EuroMov Digital Health in Motion, Univ Montpellier, IMT Mines Ales, 34090 Montpellier, France
- Corresponding author
- Imbach, Frank
- Venue
- Sports
- Publisher
- MDPI AG
- Published
- 2020-07-20
- Volume
- 8
- Issue
- 7
- Pages
- 103
- ISSN
- 2075-4663 (ISSN-L)
- PMC
- PMC7404478
- OpenAlex
- W3044114303
- Semantic Scholar
- 21955b969d00ca81f6463bcdd8a5573ef84e39d9
- Cited by
- 72
- References
- 62
- Citations by year
- 2026: 9 · 2025: 14 · 2024: 13 · 2023: 21 · 2022: 8 · 2021: 7
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Association Nationale de la Recherche et de la Technologie (2018/0653)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- running power, ground contact time, oxygen consumption, incremental running test, recreational runners
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.