Cited by 16Radiation Dose and ImagingAdvanced Radiotherapy TechniquesDigital Radiography and Breast Imaging

Relationships of radiation dose indices with body size indices in adult body computed tomography

Open access
Inoue, Yusuke, Itoh, Hiroyasu, Nagahara, Kazunori, Hata, Hirofumi, Mitsui, Kohei·2023·Tomography

Abstract

We investigated the relationships between radiation dose indices and body size indices in adult body computed tomography (CT). A total of 3200 CT scans of the thoracic, abdominal, abdominopelvic, or thoraco-abdominopelvic regions performed using one of four CT scanners were analyzed. Volume CT dose index (CTDIvol) and dose length product (DLP) were compared with various body size indices derived from CT images (water-equivalent diameter, WED; effective diameter, ED) and physical measurements (weight, weight/height, body mass index, and body surface area). CTDIvol showed excellent positive linear correlations with WED and ED. CTDIvol also showed high linear correlations with physical measurement-based indices, whereas the correlation coefficients were lower than for WED and ED. Among the physical measurement-based indices, weight/height showed the strongest correlations, followed by weight. Compared to CTDIvol, the correlation coefficients with DLP tended to be lower for WED, ED, and weight/height and higher for weight. The standard CTDIvol values at 60 kg and dose increase ratios with increasing weight, estimated using the regression equations, differed among scanners. Radiation dose indices closely correlated with body size indices such as WED, ED, weight/height, and weight. The relationships between dose and body size differed among scanners, indicating the significance of dose management considering body size.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/tomography9040110

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The present study demonstrated the lowest radiation exposure for both dose descriptors compared with modern studies.

    “The present study demonstrated the lowest radiation exposure for both dose descriptors.”

    From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [14]

    The Results (section 3.2; page unavailable) report that, at a standard body weight of 60 kg, the Siemens scanner had a lower standard dose than the other scanners studied. The Introduction identifies CTDIvol and DLP as the two dose indices. This is a comparison among scanners at one facility, not evidence that the citing study had the lowest exposure for both descriptors compared with modern studies. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • The DRLs established in this study are lower than national and international benchmarks.

    “demonstrating lower radiation doses than national and international benchmarks.”

    From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [14]

    The Introduction discusses DRLs generally, while the Results (section 3.2) compare estimated standard doses among scanners at the study facility. Searches for national and international benchmarks found no passage establishing study DRLs or comparing its doses with those benchmarks. (LLM, conf=0.76)

    Experimental — accuracy not yet measured
  • Studies in Japan reported CTDIvol 18.2 mGy and DLP 870.9 mGy·cm.

    “studies conducted in Portugal (CTDIvol: 18 mGy, DLP: 800 mGy·cm) and Japan (CTDIvol: 18.2 mGy, DLP: 870.9 mGy·cm) reflect significantly higher dose levels. 9 14”

    From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [14]

    The Results (§3.2; page unavailable) discuss CTDIvol and DLP and refer to standard-dose values in Table 3, but the passages in our copy do not give the claimed pair of values. Searches for “18.2” and “870.9” found no passage reporting those figures for Japan. (LLM, conf=0.72)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Inoue, Y., Itoh, H., Nagahara, K., Hata, H., & Mitsui, K.
Affiliations
  • Kitasato University (JP)
  • Kitasato University Hospital (JP)
Corresponding author
Inoue, Yusuke
Venue
Tomography
Publisher
MDPI AG
Published
2023-07-14
Volume
9
Issue
4
Pages
1381-1392
ISSN
  • 2379-1381 (ISSN-L)
  • 2379-139X
OpenAlex
W4384340347
Cited by
16
References
33
Citations by year
2026: 3 · 2025: 7 · 2024: 5 · 2023: 1
FWCI
2.64
Type
journal article
Language
en
Open access
Locations
  • Tomography (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Digital Radiography and Breast Imaging
Keywords
radiation dose, body size, volume CT dose index, dose-length product, water-equivalent diameter, effective diameter, body mass index, body surface area, dose management
MeSH terms
Adult, Humans, Radiation Dosage, Tomography, X-Ray Computed, Tomography Scanners, X-Ray Computed, Phantoms, Imaging, Body Size

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review