Patients’ experiences of self-monitoring blood pressure and self-titration of medication: the TASMINH2 trial qualitative study
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Self-management of hypertension, comprising self-monitoring of blood pressure with self-titration of medication, improves blood pressure control, but little is known regarding the views of patients undertaking it. AIM: To explore patients' views of self-monitoring blood pressure and self-titration of antihypertensive medication. DESIGN AND SETTING: Qualitative study embedded within the randomised controlled trial TASMINH2 (Telemonitoirng and Self Management in the Control of Hypertension) trial of patient self-management of hypertension from 24 general practices in the West Midlands. METHOD: Taped and transcribed semi-structured interviews with 23 intervention patients were used. Six family members were also interviewed. Analysis was by a constant comparative method. RESULTS: Patients were confident about self-monitoring and many felt their multiple home readings were more valid than single office readings taken by their GP. Although many patients self-titrated medication when required, others lacked the confidence to increase medication without reconsulting with their GP. Patients were more comfortable with titrating medication if their blood pressure readings were substantially above target, but were reluctant to implement such a change if readings were borderline. Many planned to continue self-monitoring after the study finished and report home readings to their GP, but few wished to continue with a self-management plan. CONCLUSION: Participants valued the additional information and many felt confident in both self-monitoring blood pressure and self-titrating medication. The reluctance to change medication for borderline readings suggests behaviour similar to the clinical inertia seen for physicians in analogous circumstances. Additional support for those lacking in confidence to implement prearranged medication changes may allow more patients to undertake self-management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
US trends in prevalence, awareness, treatment, and control of hypertension, 1988–2008
Egan, B. M. (2010) · JAMA · doi:10.1001/jama.2010.650 · Cited by 2,197
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Sever, P. S., & Poulter, N. R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60308-x · Cited by 1,784
Phillips, L. S., Branch, W. T., Cook, C. B., Doyle, J. P., El-Kebbi, I. M., Gallina, D. L., Miller, C. D., Ziemer, D. C., & Barnes, C. S. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-9-200111060-00012 · Cited by 1,370
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Mant, J., Doust, J., Roalfe, A., Barton, P., Cowie, M., Glasziou, P., Mant, D., McManus, R., Holder, R., Deeks, J., et al. (2009) · Health Technology Assessment · doi:10.3310/hta13320 · Cited by 498
Self-citationBray, E. P., Holder, R., Mant, J., & McManus, R. J. (2010) · Annals of Medicine · doi:10.3109/07853890.2010.489567 · Cited by 245
Self-citationSelf-Measurement and Self-Titration in HypertensionA Pilot Telemedicine Study
BOBRIE, G., POSTELVINAY, N., DELONCA, J., & CORVOL, P. (2007) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2007.08.011 · Cited by 68
Cited by
Interactive telemedicine: effects on professional practice and health care outcomes
Flodgren, G., Rachas, A., Farmer, A. J., Inzitari, M., & Shepperd, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002098.pub2 · Cited by 806
Vassilev, I., Rowsell, A., Pope, C., Kennedy, A., O’Cathain, A., Salisbury, C., & Rogers, A. (2015) · Implementation Science · doi:10.1186/s13012-015-0238-9 · Cited by 137
Fletcher, B. R., Hinton, L., Hartmann-Boyce, J., Roberts, N. W., Bobrovitz, N., & McManus, R. J. (2016) · Patient Education and Counseling · doi:10.1016/j.pec.2015.08.026 · Cited by 121
“Following removal of duplicates and title and abstract screening, 45 full text articles were assessed and 12 articles met the selection criteria [15-26].”
MethodSelf-citationHanley, J., Ure, J., Pagliari, C., Sheikh, A., & McKinstry, B. (2013) · BMJ Open · doi:10.1136/bmjopen-2013-002671 · Cited by 68
Patients’ preference for ambulatory versus home blood pressure monitoring
Nasothimiou, E. G., Karpettas, N., Dafni, M. G., & Stergiou, G. S. (2014) · Journal of Human Hypertension · doi:10.1038/jhh.2013.104 · Cited by 66
Metadata
- Authors
- Jones, M. I., Greenfield, S. M., Bray, E. P., Baral-Grant, S., Hobbs, F. R., Holder, R., Little, P., Mant, J., Virdee, S. K., Williams, B., & McManus, R. J.
- Venue
- British Journal of General Practice
- Published
- 2012-02
- Volume
- 62
- Issue
- 595
- Pages
- e135-e142
- ISSN
- 0960-1643 (ISSN-L)
- 1478-5242
- OpenAlex
- W2167145056
- Cited by
- 89
- References
- 7
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patients’ experiences of self-monitoring blood pressure and self-titration of medication: the TASMINH2 trial qualitative study. https://app.cochat.ai/papers/10.3399/bjgp12x625201
- The paper
- Jones, M. I., Greenfield, S. M., Bray, E. P., Baral-Grant, S., Hobbs, F. R., Holder, R., Little, P., Mant, J., Virdee, S. K., Williams, B., & McManus, R. J. (2012). Patients’ experiences of self-monitoring blood pressure and self-titration of medication: the TASMINH2 trial qualitative study. British Journal of General Practice. https://doi.org/10.3399/bjgp12x625201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.