Ergonomics of the thermal environment. Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
Open accessAbstract
13.180
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
UTCI-Fiala multi-node model of human heat transfer and temperature regulation
Fiala, D., Havenith, G., Bröde, P., Kampmann, B., & Jendritzky, G. (2012) · International Journal of Biometeorology · doi:10.1007/s00484-011-0424-7 · Cited by 994
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Forty years of Fanger’s model of thermal comfort: comfort for all?
van Hoof, J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2007.00516.x · Cited by 733
Asadi, E., Silva, M. G. D., Antunes, C. H., Dias, L., & Glicksman, L. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.06.009 · Cited by 523
Instruments and methods in outdoor thermal comfort studies – The need for standardization
Johansson, E., Thorsson, S., Emmanuel, R., & Krüger, E. (2014) · Urban Climate · doi:10.1016/j.uclim.2013.12.002 · Cited by 486
Outdoor human comfort and thermal stress: A comprehensive review on models and standards
Coccolo, S., Kämpf, J., Scartezzini, J.-L., & Pearlmutter, D. (2016) · Urban Climate · doi:10.1016/j.uclim.2016.08.004 · Cited by 417
A review of the corrective power of personal comfort systems in non-neutral ambient environments
Zhang, H., Arens, E., & Zhai, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.013 · Cited by 411
Urban Physics: Effect of the micro-climate on comfort, health and energy demand
Moonen, P., Defraeye, T., Dorer, V., Blocken, B., & Carmeliet, J. (2012) · Frontiers of Architectural Research · doi:10.1016/j.foar.2012.05.002 · Cited by 379
Schellen, L., Van Marken Lichtenbelt, W. D., Loomans, M. G. L. C., Toftum, J., & De Wit, M. H. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00657.x · Cited by 377
Health and thermal comfort: From WHO guidance to housing strategies
Ormandy, D., & Ezratty, V. (2012) · Energy Policy · doi:10.1016/j.enpol.2011.09.003 · Cited by 356
Thermal comfort in outdoor urban spaces in Singapore
Yang, W., Wong, N. H., & Jusuf, S. K. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.09.008 · Cited by 343
Personalized conditioning and its impact on thermal comfort and energy performance – A review
Veselý, M., & Zeiler, W. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.024 · Cited by 322
Relationship between psychological responses and physical environments in forest settings
Park, B.-J., Furuya, K., Kasetani, T., Takayama, N., Kagawa, T., & Miyazaki, Y. (2011) · Landscape and Urban Planning · doi:10.1016/j.landurbplan.2011.03.005 · Cited by 296
Ten questions concerning thermal comfort and ageing
van Hoof, J., Schellen, L., Soebarto, V., Wong, J. K. W., & Kazak, J. K. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.05.008 · Cited by 268
Are ‘class A’ temperature requirements realistic or desirable?
Arens, E., Humphreys, M. A., de Dear, R., & Zhang, H. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.03.014 · Cited by 260
Smart homes and the control of indoor air quality
Schieweck, A., Uhde, E., Salthammer, T., Salthammer, L. C., Morawska, L., Mazaheri, M., & Kumar, P. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.05.057 · Cited by 255
Human metabolic rate and thermal comfort in buildings: The problem and challenge
Luo, M., Wang, Z., Ke, K., Cao, B., Zhai, Y., & Zhou, X. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.005 · Cited by 231
Outdoor thermal comfort in public space in warm-humid Guayaquil, Ecuador
Johansson, E., Yahia, M. W., Arroyo, I., & Bengs, C. (2018) · International Journal of Biometeorology · doi:10.1007/s00484-017-1329-x · Cited by 149
Human convective boundary layer and its interaction with room ventilation flow
Licina, D., Melikov, A., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12120 · Cited by 104
Effects of different cooling principles on thermal sensation and physiological responses
Schellen, L., Loomans, M. G. L. C., de Wit, M. H., Olesen, B. W., & Lichtenbelt, W. D. V. M. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.01.007 · Cited by 46
Influences on the predictive performance of thermal sensation indices
Schweiker, M., & Wagner, A. (2017) · Building Research & Information · doi:10.1080/09613218.2017.1256673 · Cited by 31
Metadata
- Publisher
- BSI British Standards
- Published
- 2006-01-19
- OpenAlex
- W4230934225
- Cited by
- 1,312
- References
- 0
- Type
- standard
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.