Sub-pT magnetic field detection by tunnel magneto-resistive sensors
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
We developed tunnel magneto-resistive (TMR) sensors based on magnetic tunnel junctions (MTJs) that are able to detect a weak, sub-pT, magnetic field at a low frequency. Small detectivities of 0.94 pT/Hz 1/2 at 1 Hz and 0.05 pT/Hz 1/2 at 1 kHz were achieved by lowering the resistance of MTJs and enhancement of the signal using a thick CoFeSiB layer and magnetic flux concentrators. We demonstrated real-time measurement of magnetocardiography (MCG) and nuclear magnetic resonance (NMR) of protons using developed sensors. This result shows that both MCG and NMR can be measured by the same measurement system with ultra-sensitive TMR sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In parallel, advances in tunnel magnetoresistance (TMR) sensors demonstrate rapid progress towards compact, room-temperature biomagnetic detection. Studies report sub-picotesla sensitivity in miniaturized silicon-compatible architectures that enable real-time MCG and neuronal spike detection without cryogenic cooling.”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [50]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These developments position TMR sensors as emerging practical alternatives to cryogenic SQUID platforms, with potential applications in wearable systems and brain–machine interfaces [48,49,50].”
From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [50]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giant room-temperature magnetoresistance in single-crystal Fe/MgO/Fe magnetic tunnel junctions
Yuasa, S., Nagahama, T., Fukushima, A., Suzuki, Y., & Ando, K. (2004) · Nature Materials · doi:10.1038/nmat1257 · Cited by 3,331
Giant tunnelling magnetoresistance at room temperature with MgO (100) tunnel barriers
Parkin, S. S. P., Kaiser, C., Panchula, A., Rice, P. M., Hughes, B., Samant, M., & Yang, S.-H. (2004) · Nature Materials · doi:10.1038/nmat1256 · Cited by 3,320
Spin-dependent tunneling conductance ofFe|MgO|Fesandwiches
Butler, W. H., Zhang, X.-G., Schulthess, T. C., & MacLaren, J. M. (2001) · Physical Review B · doi:10.1103/physrevb.63.054416 · Cited by 2,102
Ikeda, S., Hayakawa, J., Ashizawa, Y., Lee, Y. M., Miura, K., Hasegawa, H., Tsunoda, M., Matsukura, F., & Ohno, H. (2008) · Applied Physics Letters · doi:10.1063/1.2976435 · Cited by 1,596
Theory of tunneling magnetoresistance of an epitaxial Fe/MgO/Fe(001) junction
Mathon, J., & Umerski, A. (2001) · Physical Review B · doi:10.1103/physrevb.63.220403 · Cited by 1,302
The Nuclear Induction Experiment
Bloch, F., Hansen, W. W., & Packard, M. (1946) · Physical Review · doi:10.1103/physrev.70.474 · Cited by 1,192
230% room-temperature magnetoresistance in CoFeB∕MgO∕CoFeB magnetic tunnel junctions
Djayaprawira, D. D., Tsunekawa, K., Nagai, M., Maehara, H., Yamagata, S., Watanabe, N., Yuasa, S., Suzuki, Y., & Ando, K. (2005) · Applied Physics Letters · doi:10.1063/1.1871344 · Cited by 967
Yuasa, S., Fukushima, A., Nagahama, T., Ando, K., & Suzuki, Y. (2004) · Japanese Journal of Applied Physics · doi:10.1143/jjap.43.l588 · Cited by 298
Magnetoresistive Random Access Memory: Present and Future
Ikegawa, S., Mancoff, F. B., Janesky, J., & Aggarwal, S. (2020) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2020.2965403 · Cited by 270
Yoda, H., Kishi, T., Nagase, T., Yoshikawa, M., Nishiyama, K., Kitagawa, E., Daibou, T., Amano, M., Shimomura, N., Takahashi, S., et al. (2010) · Current Applied Physics · doi:10.1016/j.cap.2009.12.021 · Cited by 179
Self-citation
Research works printed but not linked: 1
- T. Uchiyama and J. Ma, IEEE Trans. Magn. 55, 4400408 (2019).
Cited by
Scalp attached tangential magnetoencephalography using tunnel magneto-resistive sensors
Kanno, A., Nakasato, N., Oogane, M., Fujiwara, K., Nakano, T., Arimoto, T., Matsuzaki, H., & Ando, Y. (2022) · Scientific Reports · doi:10.1038/s41598-022-10155-6 · Cited by 60
Self-citationSpintronic devices for biomedical applications
Mostufa, S., Liang, S. A., Chugh, V. K., Wang, J., & Wu, K. (2024) · npj Spintronics · doi:10.1038/s44306-024-00031-6 · Cited by 68
Kurashima, K., Kataoka, M., Nakano, T., Fujiwara, K., Kato, S., Nakamura, T., Yuzawa, M., Masuda, M., Ichimura, K., Okatake, S., et al. (2023) · Sensors · doi:10.3390/s23020646 · Cited by 56
“5Si15B10 with excellent flatness and a soft magnetic property [23,25,26], which has been reported to lead the small anisotropy field and high sensitivity.”
BackgroundSelf-citationA review on soft pneumatic actuators with integrated or embedded soft sensors
Gariya, N., Kumar, S., Shaikh, A., Prasad, B., & Nautiyal, H. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115364 · Cited by 57
Enhanced performance and functionality in spintronic sensors
Leitão, D. C., van Riel, F. J. F., Rasly, M., Araujo, P. D. R., Salvador, M., Paz, E., & Koopmans, B. (2024) · npj Spintronics · doi:10.1038/s44306-024-00058-9 · Cited by 41
Sakib, S., Fouda, M. M., Al‐Mahdawi, M., Mohsen, A. S., Oogane, M., Ando, Y., & Fadlullah, Z. M. (2021) · IEEE Access · doi:10.1109/access.2021.3138976 · Cited by 30
“MCG and magnetoencephalography (MEG), at room temperature [15], [18], [21].”
BackgroundSelf-citationWibowo, N. A., Kurniawan, C., Kusumahastuti, D. K. A., Setiawan, A., & Suharyadi, E. (2024) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ad1f35 · Cited by 27
Various noise reduction techniques of magnetoresistive sensors and their applications: A review
Jiao, Q., Jin, Z., Zhang, C., & Chen, J. (2024) · Measurement · doi:10.1016/j.measurement.2024.116143 · Cited by 25
Tunnel-magnetoresistance sensors with sub-pT detectivity for detecting bio-magnetic fields
Nakano, T., Fujiwara, K., & Oogane, M. (2025) · Applied Physics Letters · doi:10.1063/5.0263879 · Cited by 22
Self-citationRecent advances in magnetoresistance biosensors: a short review
Dey, C., Yari, P., & Wu, K. (2023) · Nano Futures · doi:10.1088/2399-1984/acbcb5 · Cited by 22
“With the addition of MFCs, magnetic field detectivity down to sub-pTesla can be easily achieved [26, 74–78], coupled with simple fabrication techniques and low cost, it is easy to see why MTJs have gained popularity in biosensing research.”
InfluentialIchinose, T., Ikeda, J., Onodera, Y., Tsuchiya, T., Suzuki, K. Z., & Mizukami, S. (2023) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2023.170750 · Cited by 22
Self-citationAn Integrated Magnetometer Module With MFCs Based on Diamond NV Centers
Mao, X., Huang, K., Ran, G., Huang, Q., Qu, S., He, X., Hu, Q., & Lin, Z. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3284520 · Cited by 20
Nakatani, T. M., Suto, H., Kulkarni, P. D., Iwasaki, H., & Sakuraba, Y. (2022) · Applied Physics Letters · doi:10.1063/5.0119677 · Cited by 19
Kulkarni, P. D., Iwasaki, H., & Nakatani, T. M. (2022) · Sensors · doi:10.3390/s22239385 · Cited by 17
“, Hall [7,8], anisotropic magnetoresistance [9], GMR [3,10,11], and tunnel magnetoresistance [12,13] sensors.”
BackgroundPerspective: magnetic quantum sensors for biomedical applications
Wu, K., & He, R. (2025) · Nanotechnology · doi:10.1088/1361-6528/adb635 · Cited by 19
“MTJ sensors exhibit the highest resistance change (up to 600% or more) among all MR sensors and extreme sensitivity for magnetic field detection (pT/sqrt(Hz)) [84, 85].”
Self-powered elementary hybrid magnetoelectric sensor
Gerhardt, M., Zimoch, L., Dorn, C., Elzenheimer, E., Bald, C., Lerg, T., Hoffmann, J., Kaps, S., Höft, M., Schmidt, G. U., et al. (2023) · Nano Energy · doi:10.1016/j.nanoen.2023.108720 · Cited by 15
Recent advances in formaldehyde sensors: a review
Wang, L., Song, J. T., & Yu, C. (2024) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-024-03026-6 · Cited by 13
Nakano, T., Fujiwara, K., Tsunoda, M., Kumagai, S., & Oogane, M. (2023) · Applied Physics Letters · doi:10.1063/5.0162276 · Cited by 12
Self-citationManceau, S., Brun, T., Fischer, J., Ducruet, C., Sabon, P., Cavoit, C., Jannet, G., Pinçon, J., Prejbeanu, L., Kretzschmar, M., et al. (2023) · Applied Physics Letters · doi:10.1063/5.0160544 · Cited by 12
Kikitsu, A., Higashi, Y., Kurosaki, Y., Shirotori, S., Nagatsuka, T., Suzuki, K., & Terui, Y. (2022) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ac9145 · Cited by 11
Magnetic Sensors: Principles, Methodologies, and Applications
Elzwawy, A., Rasly, M., Morsy, M., Pişkin, H., & Volmer, M. (2023) · Springer eBooks · doi:10.1007/978-3-031-16338-8_33-1 · Cited by 11
Imamura, H., Arai, H., Matsumoto, R., & Yamaji, T. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.014032 · Cited by 11
Sun, K., Jiang, Z., Wang, C., Han, D., Yao, Z., Zong, W.-H., Jin, Z., & Li, S. (2023) · Sensors · doi:10.3390/s23031702 · Cited by 10
“Most magnetoresistance sensors have relatively low magnetic field sensitivity; however, recently, the sensitivity of tunneling magnetoresistance sensors has been greatly improved, in the order of sub-pT [7].”
BackgroundMagnetic tunnel junctions using epitaxially grown FeAlSi electrode with soft magnetic property
Akamatsu, S., Oogane, M., Tsunoda, M., & Ando, Y. (2022) · AIP Advances · doi:10.1063/5.0094619 · Cited by 10
Self-citationNakatani, T. M., Suto, H., Kulkarni, P. D., Iwasaki, H., & Sakuraba, Y. (2023) · Journal of Applied Physics · doi:10.1063/5.0180812 · Cited by 9
Development of Tunnel Magneto-Resistive Sensors
Oogane, M. (2023) · IEICE Transactions on Electronics · doi:10.1587/transele.2023sei0001 · Cited by 9
Self-citationFew-Shot Magnet Localization Using Sim-to-Real Transfer Learning
Wang, Y., Pittiglio, G., Lin, X., & Dupont, P. E. (2025) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2025.3623010 · Cited by 8
“The sensors may be Hall effect sensors [13], magneto-resistive sensors [14] or magneto-inductive sensors [15].”
Parallel array of planar Hall effect sensors for high resolution magnetometry
Nhalil, H., Schultz, M., Amrusi, S., Grosz, A., & Klein, L. (2023) · Journal of Applied Physics · doi:10.1063/5.0151569 · Cited by 8
Ohkubo, M. (2023) · Review of Scientific Instruments · doi:10.1063/5.0167372 · Cited by 9
Oda, H., Kumagai, S., Fujiwara, K., Matsuzaki, H., Wagatsuma, H., Oogane, M., Kubota, H., Fukuyo, N., & Tanimoto, A. (2024) · Earth Planets and Space · doi:10.1186/s40623-024-02118-0 · Cited by 8
“Recently, the sensitivity of TMR sensors with CoFeB/ MgO/CoFeB-MTJs has been improved allowing the detection of weak biomagnetic fields such as brain magnetic fields (magnetoencephalography: MEG) (Oogane et al. 2021).”
InfluentialSelf-citationNakano, T., Fujiwara, K., Kumagai, S., Ando, Y., & Oogane, M. (2023) · Applied Physics Letters · doi:10.1063/5.0132866 · Cited by 7
Self-citationUltrasensitive Magnetometer Based on Cusp Points of the Photon-Magnon Synchronization Mode
Mi, X., Rao, J., Yan, L., Wang, X. L., Lyu, B., Yao, B., Yan, S., & Bai, L. (2026) · Physical Review Letters · doi:10.1103/dkwj-jv6l · Cited by 11
Synthesis strategies of magnetic inorganic nanomaterials to biomedical and spintronic applications
Thắng, N. H. (2026) · Chemical Papers · doi:10.1007/s11696-026-04706-8 · Cited by 6
“For exam - ple, Oogane et al. (2021 ) developed an MTJ array compris - ing 74 serially connected junctions integrated with T-shaped magnetic flux concentrators (MFCs).”
Human cardiac measurements with diamond magnetometers
Omar, M., Benke, M., Zhang, S., Zhang, J., Wang, Y., Kübler, M., Sharbati, P., Rahimpour, A., Gueck, A., Kapitonova, M., et al. (2026) · Science Advances · doi:10.1126/sciadv.aeg5281 · Cited by 8
“Other magnetometers, such as fluxgate sensors and magnetore-sistive sensors, have also been demonstrated to detect MCG signals [3, 4].”
Feasibility study of magnetic sensing for detecting single-neuron action potentials
Tonini, D., Kai, W., Saha, R., & Wang, J. (2022) · Annals of Biomedical Science and Engineering · doi:10.29328/journal.abse.1001018 · Cited by 7
Šmits, J., Silani, Y., Peng, Z., Richards, B. A., McDowell, A. F., Damron, J. T., Aiello, M. D., Ziabari, M. S., Jarmola, A., & Acosta, V. M. (2025) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.5c00134 · Cited by 7
“Various sensors have been pursued, including those based on superconducting quantum interference devices [11, 12], magnetoresistance sensors [13, 14], alkali-metal vapor magnetometers [15, 16], and, recently, magnetometers based on nitrogen-vacancy (NV) centers in diamond [17–23].”
Magnetic Hammer Testing With Tunnel Magnetoresistive Sensors
Ito, J., Al‐Mahdawi, M., & Oogane, M. (2023) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2023.3282988 · Cited by 6
Self-citationFabrication of GMR Sensors With Antiphase Magnetization Modulation and Closed-Loop Operation
Komuro, K., Oshima, D., & Kato, T. (2023) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2023.3284398 · Cited by 6
“Recently, tunnel MR (TMR) sensors are used to detect sub-pT field [9] for magnetocardiogra-phy (MCG) [10] and magnetoencephalography (MEG) [11] at room temperature.”
MethodMagnetic anisotropy and damping in epitaxial Fe-Co-Ni binary and ternary alloy thin films
Ueno, T., Nakano, T., Tsunoda, M., Yamashita, S., Hojo, T., & Oogane, M. (2025) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2025.172841 · Cited by 5
Self-citationBi, R., Zhang, H., Pan, S., Liu, X., Chen, R., Wu, S., & Hu, J. (2025) · Sensors · doi:10.3390/s25154739 · Cited by 5
“Other research groups introduced materials such as CoFeSiB [16] and CoFeBTa [17] to enhance the soft magnetic properties of the free layer in TMR sensors, thereby increasing sensitivity.”
Application of probabilistic bits in measurement and sensing
Liu, Y., & Xiao, J. (2025) · Applied Physics Letters · doi:10.1063/5.0253449 · Cited by 4
Kulkarni, P. D., & Nakatani, T. M. (2024) · Applied Physics Letters · doi:10.1063/5.0231451 · Cited by 4
Key performance of tunneling magnetoresistance sensing unit modulated by exchange bias of free layer
Feng, J., Chen, X., Wei, H., Chen, P., Lan, G., Liu, Y., Guo, J., Huang, H., & Han, X.-F. (2023) · Acta Physica Sinica · doi:10.7498/aps.72.20231003 · Cited by 4
Electronic Interface Design Considerations for Biomagnetic Sensing Using TMR Sensors
Wang, H., Ahmad, M., Tanwear, A., Arekhloo, N. G., Zuo, S., Nazarpour, K., & Heidari, H. (2025) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2025.3577734 · Cited by 4
“The 5–100 Hz band captures lower-frequency components that are typical in many biomagnetic signals, including those associated with cardiac and neurophysiological activity [37], [38].”
Long-range stray field mapping of statically magnetized nanoparticles using magnetoresistive sensor
Trisnanto, S. B., Kasajima, T., Akushichi, T., & Takemura, Y. (2022) · Journal of Applied Physics · doi:10.1063/5.0091365 · Cited by 4
Trisnanto, S. B., Kasajima, T., Shibuya, T., & Takemura, Y. (2023) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2023.3275541 · Cited by 5
“Through proper signal processing, the MR sensor is capable of performing sub-pT oscillatory magnetometry [13], [14].”
MethodNoise characterization of STT-based Nanoscale magnetic tunnel junction magnetic sensors
Komuro, K., Nicolas, H., Diény, B., Oshima, D., Kato, T., & Sousa, R. C. (2025) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2025.173215 · Cited by 4
Sinha, R., & Kaur, J. (2024) · Multimedia Tools and Applications · doi:10.1007/s11042-024-19378-3 · Cited by 4
Nguyễn, T. N. A., Pham, Q. N., Do, K. T., Ky, V. H., Pham, H. N., Tran, D. T., & M., H. (2025) · Applied Physics A · doi:10.1007/s00339-025-08630-8 · Cited by 3
Research progress of performance optimization of tunnel magnetoresistive sensors
Yuanzhen, L. I. U., Lei, S., Zhang, S., Pan, M., Hu, Y., Hu, J., Junping, P. E. N. G., Du, Q., ZHANG, Q., & Li, P. (2025) · Acta Physica Sinica · doi:10.7498/aps.75.20251597 · Cited by 3
Effective measurement of magnetic tunneling junction noise based on the equivalent noise model
Zhang, X., Ji, M., Pan, M., Sun, K., Hu, Y., Du, Q., Li, P., Peng, J., Hu, J., & Qiu, W. (2023) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2023.170930 · Cited by 3
Hojo, T., Hamasaki, H., Tsunoda, M., & Oogane, M. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.172144 · Cited by 3
Self-citationDomain Wall Displacement Modulation GMR Sensors with Closed-Loop Current-Field Feedback
Komuro, K., Oshima, D., & Kato, T. (2024) · Journal of the Magnetics Society of Japan · doi:10.3379/msjmag.2403r004 · Cited by 2
Pandey, S., Shukla, H., Mishra, V., Pal, S., Prajapati, Y. K., & Verma, A. (2026) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2025.3650609 · Cited by 2
“Hall effect sensors [7] and magneto-resistive sensors [8] are currently the most frequently used magnetic field sensors.”
3D‐Printed Giant Magnetoresistive (GMR) Sensors Based on Self Compliant Springs
Maestu, J. F., Pereira, N., Vicente, J., Tubio, C. R., & Lanceros-Méndez, S. (2026) · Advanced Engineering Materials · doi:10.1002/adem.202502565 · Cited by 2
“…magnetoresistance (TMR) sensors, sensitivities in the range of tens to hundreds of mV/T are present, along with wide dynamic ranges extending from μ T to T levels, size and bandwidths reaching several kHz, supported by mature semiconductor fabrication and signal conditioning electronics [45 – 47].”
Bindal, N., Pathak, P., Aziz, Z., Raj, R. K., Yadav, S., Soni, S., Dhull, S., Mallick, D., Mishra, Y. K., Srikanth, H., et al. (2026) · IEEE electron devices reviews. · doi:10.1109/edr.2026.3694617 · Cited by 2
“TMR sensor sensitivity has reached 940 fT/Hz at 1 Hz and 50 fT/Hz at 1 kHz with magnetic flux concentrators [96], sufficient for somatosensory evoked magnetic field measurement used in clinical MEG functional mapping [97].”
Evaluation of Pipe Thickness by Magnetic Hammer Test with a Tunnel Magnetoresistive Sensor
Ito, J., Igarashi, Y., Odagiri, R., Suzuki, S., Wagatsuma, H., Sugiyama, K., & Oogane, M. (2024) · Sensors · doi:10.3390/s24051620 · Cited by 2
“The combination of these materials and structures dramatically increased the sensitivity of the TMR sensor and achieved a detectivity of 50 fT/ √ Hz@1 kHz [23].”
BackgroundSelf-citationManikketh, M. K., Kulkarni, P. D., Nakatani, T. M., Suto, H., & Sakuraba, Y. (2024) · Journal of Applied Physics · doi:10.1063/5.0231800 · Cited by 2
Tunnel anisotropic magnetoresistance in magnetic tunnel junctions using FeAlSi
Akamatsu, S., Nakano, T., Al‐Mahdawi, M., Yupeng, W., Tsunoda, M., Ando, Y., & Oogane, M. (2023) · AIP Advances · doi:10.1063/9.0000440 · Cited by 2
Self-citationPortable Magnetic Detectors Based on TMR Sensors
Li, Z., He, A., Zhu, H., Wang, H., Zhao, Y., & Kong, X. (2023) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2525/1/012014 · Cited by 2
Magnetic Sensors: Principles, Methodologies, and Applications
Elzwawy, A., Rasly, M., Morsy, M., Pişkin, H., & Volmer, M. (2024) · Springer eBooks · doi:10.1007/978-3-031-47180-3_33 · Cited by 2
Palantzas, A., & Anagnostouli, M. (2026) · Sensors · doi:10.3390/s26051738 · Cited by 1
“These developments position TMR sensors as emerging practical alternatives to cryogenic SQUID platforms, with potential applications in wearable systems and brain–machine interfaces [48–50].”
Gopika, C. T., Prajisha, K. P., Kaul, A., Borole, U. P., Khan, J., Behera, B., & Chowdhury, P. (2025) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2025.172812 · Cited by 1
A Simulation Method for Response and Noise of Magnetic Tunnel Junctions
Lei, S., Zhang, S., Liu, Y., Mengchun, P., Hu, J., Hu, Y., Junping, P., Weicheng, Q., Fang, B., Wen, L., et al. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3625132 · Cited by 1
“5 were also demonstrated [8], [9], [10], [11], [12], [13], [14], [15].”
Multi-level Gated U-Net for Denoising TMR Sensor-Based MCG Signals
Xing, Z., Li, H., Dou, H., Zheng, Z., 戴经国, Wang, C., Cui, J., Zhang, X., & Jiang, T. (2025) · Lecture notes in computer science · doi:10.1007/978-3-032-04947-6_41 · Cited by 1
Peng, G., Shi, J., Zhang, H., Jiao, Q., Jin, Z., & Chen, J. (2026) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2026.100975 · Cited by 1
Oda, H., Fujiwara, K., Fukuyo, N., KUBOTA, H., Ichinose, T., Oogane, M., Kumagai, S., Matsuzaki, H., UCHIDA, T., Kawabata, M., et al. (2026) · Sensors · doi:10.3390/s26031075 · Cited by 1
“Recent advances of TMR sensors with CoFeB/MgO/CoFeB-MTJs have improved the sensitivity, allowing the detection of weak biomagnetic fields, such as brain magnetic fields [22].”
Self-citationKomuro, K., Kawamura, A., Suto, H., Nakatani, T. M., Oshima, D., & Kato, T. (2026) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2026.174050 · Cited by 1
Nguyen, T. N. A., Pham, Q. N., Chu, V. T., Tung, D. K., Nguyen, T. H., Pham, H. N., Goto, M., Fukumoto, M., Tomita, H., Watanabe, T., et al. (2023) · MATERIALS TRANSACTIONS · doi:10.2320/matertrans.mt-mg2022017 · Cited by 1
Magnetic Hammer Testing with Tunnel Magnetoresistive Sensors
Ito, J., Al‐Mahdawi, M., & Oogane, M. (2023) · IEEE International Magnetic Conference - Short Papers (INTERMAG Short Papers) · doi:10.1109/intermagshortpapers58606.2023.10228765 · Cited by 1
Self-citationMagnetic Resonance Imaging Using a Magnetoresistive Sensor with a Flux Transformer
Oyama, D., Adachi, Y., & Tsuyuguchi, N. (2023) · IEEE International Magnetic Conference - Short Papers (INTERMAG Short Papers) · doi:10.1109/intermagshortpapers58606.2023.10228634 · Cited by 2
Micromagnetic Neural Stimulation and Spintronic Neural Sensing
Saha, R., Tonini, D., Hopper, M. S., Goyal, A., Yuen, J., Oh, Y., Sanger, Z. T., Faramarzi, S., Shiao, M. L., Helden, D. A. V., et al. (2024) · IEEE International Magnetic Conference - Short Papers (INTERMAG Short Papers) · doi:10.1109/intermagshortpapers61879.2024.10576875 · Cited by 1
“Three advances in design enable its sensitivity for the detection of neural acvitity, the usage of flux-concentrator, thick ultra soft magnetic free layer and connection in series [9]–[13].”
BackgroundPreparation of high sensitivity and low noise tunnel junction magnetoresistive devices
Bi, R., Liu, X., Ma, H., Zhang, H., Wu, S., & Hu, J. (2024) · IEEE International Conference on High Voltage Engineering and Application (ICHVE) · doi:10.1109/ichve61955.2024.10676171 · Cited by 1
Masoumi, H. G., Ghobadi, N., & Daqiq, R. (2024) · Indian Journal of Physics · doi:10.1007/s12648-024-03504-w · Cited by 1
Magnetic anisotropy of Co/h-BN heterostructures: First principles calculations
Hastuti, D. P., Kitaoka, Y., & Imamura, H. (2025) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2025.173282 · Cited by 1
Mizuochi, N. (2022) · Nature Physics · doi:10.1038/s41567-022-01798-3 · Cited by 1
Spin-orbit torque and spin dependent transport in magnetic nano-heterostructures
Ma, T. (2023) · theses.fr (ABES) · doi:10.70675/7761dd18z0ce4z47cdz9affz89780cf9d8a0 · Cited by 1
Modeling of a magnetic field sensor based on spin Hall magnetoresistancePreprint
Bukhari, S. F., Magni, A., Skowroński, W., Losero, E., Basso, V., Appino, C., Wiśniowski, P., Langer, J., Ocker, B., Daghero, D., et al. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2602.18338 · Cited by 1
“These novel spintronic magnetic field sensors are increasingly replacing traditional magnetic field sensors, such as Hall sensors, because they offer higher sensitivity and better miniaturization perspectives [10, 11].”
Magnetic Resonance Imaging Using a Magnetoresistive Sensor With a Flux Transformer
Oyama, D., Adachi, Y., & Tsuyuguchi, N. (2023) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2023.3282634
“Magnetic resonance signal detection using a tunnel magnetoresistive (TMR) sensor has already been reported [14]; however, the influence of employing a flux concentrator has not yet been discussed.”
BackgroundPrediction of Magnetocrystalline Anisotropy Constant in FeCoNi Alloys Using Machine Learning
Sudo, R., & Oogane, M. (2023) · IEEE International Magnetic Conference - Short Papers (INTERMAG Short Papers) · doi:10.1109/intermagshortpapers58606.2023.10228569
“On the other hand, for soft magnetic materials used in high-sensitivity TMR magnetic sensors [2], it is considered difficult to search for materials by first-principles calculations because the magnitude of K is very small.”
BackgroundSelf-citationKawai, J. (2024) · TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan) · doi:10.2221/jcsj.59.19
Bouteldja, N., Belabbas, M., & Taleb, R. (2024) · East European Journal of Physics · doi:10.26565/2312-4334-2024-1-25
Development of Magnetic Hammering Test using Tunnel Magneto-resistive Sensor
Ito, J., Igarashi, Y., & Oogane, M. (2024) · IEEJ Transactions on Fundamentals and Materials · doi:10.1541/ieejfms.144.325
Self-citationProgress on Development of Highly Sensitive Tunnel Magneto-resistive Sensor
Oogane, M., Nakano, T., & Fujiwara, K. (2024) · IEEJ Transactions on Fundamentals and Materials · doi:10.1541/ieejfms.144.306
Self-citationAn Ultra Sensitive Malaria Detection Platform Based on Magnetic Biosensors
Cheng, Y., van Haren, R. F. J., Wang, H., Ranford-Cartwright, L. C., Mirzai, N., & Heidari, H. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10784722
“This work uses the state-of-art TMR sensor from Tohoku University, which can achieve extremely low magnetic field detectivity of 0.5 pT/Hz 1/2 at 1 kHz [6].”
InfluentialDevelopment of Magnetic Hammering Test Using Tunnel Magneto‐Resistive Sensor
Ito, J., Igarashi, Y., & Oogane, M. (2025) · Electronics and Communications in Japan · doi:10.1002/ecj.12469
Self-citationMagnetic field detection with single mode spin wave interference in asymmetric structure
Nishitani, Y., Kaneko, Y., & Sekiguchi, K. (2025) · Scientific Reports · doi:10.1038/s41598-025-89367-5
“For instance, the detectivity of a single tunnel magnetoresistance element without array structures and magnetic flux concentrators (MFC) is approximately 0.1 nT/ √ Hz 33,34 .”
InfluentialA Magnetic Field Sensor With No Electric Field Perturbation Based on Dual LiNbO3 Crystals
Zhang, J., He, S., Chen, Z., Li, Y., & Zhang, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3547506
“Oogane et al. [8] developed a tunnel magne-toresistance (TMR) sensor capable of detecting weak magnetic fields with a sensitivity of 0.94 pT/Hz (1/2) at 1 Hz and 0.05 pT/Hz (1/2) at 1 kHz.”
InfluentialUltra-soft magnetic properties in Ta/NiFe laminated system
Gopika, C. T., Kaul, A., Behera, B., Ghosh, S. K., Biswas, A., Sahoo, S. K., Jammalamadaka, S. N., & Chowdhury, P. (2025) · Journal of Applied Physics · doi:10.1063/5.0283171
Komuro, K., Oshima, D., & Kato, T. (2025) · Journal of the Magnetics Society of Japan · doi:10.3379/msjmag.2511r007e
Tikhonov, R. D., Demin, G. D., Cheremisinov, A. A., & Tikhonov, M. R. (2025) · Crystallography Reports · doi:10.1134/s106377452560125x
Takano, S., Nakano, T., Kubota, T., Fujiwara, K., Kumagai, S., Matsuzaki, H., Sasaki, S., Higo, Y., Sakai, L., Hosomi, M., et al. (2026) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ae332b
“The CoFeSiB/Ta/CoFeB free layer showed soft magnetic properties due to the relatively thick and soft magnetic CoFeSiB layer via weak ferromagnetic coupling through the thin Ta layer [17].”
Self-citationMaximizing TMR Sensor Resolution Via Optimized Magnetic Flux Concentrators
Tanwear, A., O'Hanlon, P., Wang, H., Rasly, M., Zuo, S., Nazarpour, K., & Heidari, H. (2025) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors59705.2025.11330712
“The current state-of-the-art TMR sensors comprise of 74 series-connected junctions, with the tunnel junction measuring 50 × 50 µm 2 and a TMR of 170% [6].”
The Effects of MFC Material and Geometry on TMR Sensing Properties
O'Hanlon, P., Wang, H., Tanwear, A., Rasly, M., Zuo, S., Nazarpour, K., & Heidari, H. (2025) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors59705.2025.11330875
“Furthermore, the relative benefits of internal MFC integration versus external MFC inserts have not been adequately evaluated in compact sensor designs [13, 14].”
Magnetic tunnel junctions incorporating a cubic GaN x tunnel barrier
Kumar, D. D., Hyeokjin, K., Suzuki, K., Miki, S., Ichinose, T., & Mizukami, S. (2026) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ae41fc
Self-citationSudo, R., Ueno, T., Yamashita, S., & Oogane, M. (2026) · AIP Advances · doi:10.1063/9.0000967
Self-citationResearch on Diamond Quantum Sensors
Mizuochi, N. (2026) · Vacuum and Surface Science · doi:10.1380/vss.69.62
Integration of Spintronic Readout for High-Bandwidth Displacement Transduction in MEMS Devices
Mota, F. C., Talantsev, A. D., Benetti, L., Garcia, I. S., Dias, R. A., Ferreira, R., & Alves, F. S. (2026) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems64181.2026.11419432
“In this context, Magnetic Tunnel Junctions (MTJs) are promising candidates, as they can detect very small changes in the magnetic field, H , below 1 pT [3].”
Ito, J., Hojo, T., Nakano, T., Wagatsuma, H., Fujiwara, K., & Oogane, M. (2026) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ae5748
Self-citationGarcia, M. J. (2022) · theses.fr (ABES) · doi:10.70675/80cad845z9ba3z447bzb6aaza04d680d3050
Metadata
- Authors
- Oogane, M., Fujiwara, K., Kanno, A., Nakano, T., Wagatsuma, H., Arimoto, T., Mizukami, S., Kumagai, S., Matsuzaki, H., Nakasato, N., & Ando, Y.
- Affiliations
- Tohoku University (JP)
- Konica Minolta (Japan) (JP)
- Corresponding author
- Oogane, Mikihiko
- ORCID
- Venue
- Applied Physics Express
- Publisher
- IOP Publishing
- Published
- 2021-11-22
- Volume
- 14
- Issue
- 12
- Pages
- 123002
- ISSN
- 1882-0778 (ISSN-L)
- 1882-0786
- OpenAlex
- W3213224992
- Cited by
- 110
- References
- 34
- Citations by year
- 2026: 28 · 2025: 24 · 2024: 23 · 2023: 26 · 2022: 8 · 2021: 1
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- Locations
- Applied Physics Express (publishedVersion, cc-by)
- Funders
- Japan Science and Technology Agency
- Center for Spintronics Research Network, Tohoku University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Magnetic properties of thin films
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetic tunnel junctions, detectivity, magnetic flux concentrators, magnetocardiography, 1H NMR
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.