Microencapsulation of Cells Producing Therapeutic Proteins: Optimizing Cell Growth and Secretion
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Microencapsulation of genetically engineered cells may have important applications as delivery systems for therapeutic proteins. However, optimization of the microcapsules with regard to mechanical stability, cell growth, and secretion of proteins is necessary in order to evaluate the future use of this delivery technology. We have explored the growth, survival, and secretion of therapeutic proteins from 293-EBNA cells producing endostatin (293 endo cells) and JJN3 myeloma cells producing hepatocyte growth factor (HGF) that have been embedded in various types of alginate capsules. Parameters that affect capsule integrity such as homogenous and inhomogenous gel cores and addition of an outer poly-l-lysine (PLL)–alginate coating were evaluated in relation to cell functions. When cells were encapsulated, the PLL layer was found to be absolutely required for the capsule integrity. The JJN3 and 293 endo cells displayed completely different growth and distribution patterns of live and dead cells within the microcapsules, as shown by 3D pictures reconstructed from images taken with confocal laser scanning microscopy (CLSM). Encapsulated JJN3 cells showed a bell-shaped growth and HGF secretion curve over a time period of 5 months. The 293 endo cells reached a plateau phase in growth after 23 days postencapsulation; however, after around 30 days a fraction of the microcapsules started to disintegrate. Microcapsule disintegration occurred with time irrespective of capsule and cell type, showing that alginate microcapsules possessing relatively high gel strength are not strong enough to keep proliferating cells within the microcapsules for prolonged time periods. Although this study shows that the stability of an alginate-based cell factory can be increased by a PLL–alginate coating, further improvement is necessary with regard to capsule integrity as well as controlling the cell growth before this technology can be used for therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microencapsulated Islets as Bioartificial Endocrine Pancreas
Lim, F., & Sun, A. M. (1980) · Science · doi:10.1126/science.6776628 · Cited by 2,377
Solid stress inhibits the growth of multicellular tumor spheroids
Helmlinger, G., Netti, P. A., Lichtenbeld, H. C., Melder, R. J., & Jain, R. K. (1997) · Nature Biotechnology · doi:10.1038/nbt0897-778 · Cited by 859
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Cited by
Effect of Ca2+, Ba2+, and Sr2+ on Alginate Microbeads
Mørch, Ý. A., Donati, I., Strand, B. L., & Skjåk-Bræk, G. (2006) · Biomacromolecules · doi:10.1021/bm060010d · Cited by 863
Self-citationPolymers in cell encapsulation from an enveloped cell perspective
de Vos, P., Lazarjani, H. A., Poncelet, D., & Faas, M. M. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.005 · Cited by 298
“suchmaterials are available [55,64], but others doubtwhether suchmaterials can ever be designed [65–67].”
Causes of limited survival of microencapsulated pancreatic islet grafts
de Groot, M., Schuurs, T. A., & van Schilfgaarde, R. (2004) · Journal of Surgical Research · doi:10.1016/j.jss.2004.02.018 · Cited by 170
“The PLL layer can be modified, which makes it possible to achieve many different grades of permeability [15, 16].”
BackgroundMaguire, T., Novik, E., Schloss, R., & Yarmush, M. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20748 · Cited by 159
“3B), following an initial lag-phase, which can be explained either by cell acclimation to the bead environment, (a phenomena that has been reported in other encapsulation systems (Rokstad et al., 2002)), or an initial balance between cell proliferation and cell death.”
BackgroundAlginate Composition Effects on a Neural Stem Cell–Seeded Scaffold
Purcell, E. K., Singh, A., & Kipke, D. R. (2009) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2008.0302 · Cited by 95
Metadata
- Authors
- Rokstad, A. M., Holtan, S., Strand, B., Steinkjer, B., Ryan, L., Kulseng, B., Skjåk-Bræk, G., & Espevik, T.
- Venue
- Cell Transplantation
- Publisher
- SAGE Publications
- Published
- 2002-05
- Volume
- 11
- Issue
- 4
- Pages
- 313-324
- ISSN
- 0963-6897 (ISSN-L)
- 1555-3892
- OpenAlex
- W1936440991
- Cited by
- 81
- References
- 3
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microencapsulation of Cells Producing Therapeutic Proteins: Optimizing Cell Growth and Secretion. https://app.cochat.ai/papers/10.3727/000000002783985774
- The paper
- Rokstad, A. M., Holtan, S., Strand, B., Steinkjer, B., Ryan, L., Kulseng, B., Skjåk-Bræk, G., & Espevik, T. (2002). Microencapsulation of Cells Producing Therapeutic Proteins: Optimizing Cell Growth and Secretion. Cell Transplantation. https://doi.org/10.3727/000000002783985774
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.