Validation of Musculoskeletal Ultrasound to Assess and Quantify Muscle Glycogen Content. A Novel Approach
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Glycogen storage is essential for exercise performance. The ability to assess muscle glycogen levels should be an important advantage for performance. However, skeletal muscle glycogen assessment has only been available and validated through muscle biopsy. We have developed a new methodology using high-frequency ultrasound to assess skeletal muscle glycogen content in a rapid, portable, and noninvasive way using MuscleSound (MuscleSound, LCC, Denver, CO) technology. PURPOSE: To validate the utilization of high-frequency musculoskeletal ultrasound for muscle glycogen assessment and correlate it with histochemical glycogen quantification through muscle biopsy. METHODS: Twenty-two male competitive cyclists (categories: Pro, 1-4; average height, 183.7 ± 4.9 cm; average weight, 76.8 ± 7.8 kg) performed a steady-state test on a cyclergometer for 90 minutes at a moderate to high exercise intensity, eliciting a carbohydrate oxidation of 2-3 g·min⁻¹ and a blood lactate concentration of 2 to 3 mM. Pre- and post-exercise glycogen content from rectus femoris muscle was measured using histochemical analysis through muscle biopsy and through high-frequency ultrasound scans using MuscleSound technology. RESULTS: Correlations between muscle biopsy glycogen histochemical quantification (mmol·kg⁻¹) and high-frequency ultrasound methodology through MuscleSound technology were r = 0.93 (P < 0.0001) pre-exercise and r = 0.94 (P < 0.0001) post-exercise. The correlation between muscle biopsy glycogen quantification and high-frequency ultrasound methodology for the change in glycogen from pre- and post-exercise was r = 0.81 (P < 0.0001). CONCLUSION: These results demonstrate that skeletal muscle glycogen can be measured quickly and noninvasively through high-frequency ultrasound using MuscleSound technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diet, muscle glycogen and physical performance.
Bergström, J., Hermansen, L., Hultman, E., & Saltin, B. (1967) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1967.tb03720.x · Cited by 1,740
Muscle glycogen utilization during prolonged strenuous exercise when fed carbohydrate
Coyle, E. F., Coggan, A. R., Hemmert, M. K., & Ivy, J. L. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.1.165 · Cited by 1,022
Measurement of substrate oxidation during exercise by means of gas exchange measurements
Jeukendrup, A. E., & Wallis, G. A. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830512 · Cited by 799
Muscle Glycogen during Prolonged Severe Exercise
Hermansen, L., Hultman, E., & Saltin, B. (1967) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1967.tb03719.x · Cited by 752
Gollnick, P. D., Piehl, K., & Saltin, B. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010639 · Cited by 643
Muscle glycogen stores and fatigue
Ørtenblad, N., Westerblad, H., & Nielsen, J. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2013.251629 · Cited by 353
Impaired muscle glycogen resynthesis after eccentric exercise
Costill, D. L., Pascoe, D. D., Fink, W. J., Robergs, R. A., Barr, S. I., & Pearson, D. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.1.46 · Cited by 173
Human muscle glycogen resynthesis after exercise: insulin-dependent and -independent phases
Price, T. B., Rothman, D. L., Taylor, R., Avison, M. J., Shulman, G. I., & Shulman, R. G. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.1.104 · Cited by 168
Metabolism of sugars and physical performance
Sherman, W. (1995) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/62.1.228s · Cited by 69
Muscle glycogen recovery after exercise during glucose and fructose intake monitored by13C-NMR
Van Den Bergh, A. J., Houtman, S., Heerschap, A., Rehrer, N. J., Van Den Boogert, H. J., Oeseburg, B., & Hopman, M. T. E. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.4.1495 · Cited by 30
Cited by
Damas, F., Libardi, C. A., & Ugrinowitsch, C. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-017-3792-9 · Cited by 254
“2009), and intramuscular glycogen (Hill and Millan 2014) can also affect muscle echo intensity, but not likely in a time course in which muscle damage is often measured (e.g. 24–120-h post RE) (Damas et al.”
BackgroundGreater neural adaptations following high- vs. low-load resistance training
Jenkins, N. D. M., Miramonti, A. A., Hill, E. C., Smith, C. M., Cochrane-Snyman, K. C., Housh, T. J., & Cramer, J. T. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00331 · Cited by 197
Winning the war against ICU-acquired weakness: new innovations in nutrition and exercise physiology
Wischmeyer, P. E., & San-Millan, I. (2015) · Critical Care · doi:10.1186/cc14724 · Cited by 153
Measuring Muscle Mass and Strength in Obesity: a Review of Various Methods
Sizoo, D., de Heide, L. J. M., Emous, M., van Zutphen, T., Navis, G., & van Beek, A. P. (2021) · Obesity Surgery · doi:10.1007/s11695-020-05082-2 · Cited by 77
Metadata
- Authors
- Hill, J. C., & Millán, I. S.
- Venue
- The Physician and Sportsmedicine
- Publisher
- Informa UK Limited
- Published
- 2014-09
- Volume
- 42
- Issue
- 3
- Pages
- 45-52
- ISSN
- 0091-3847 (ISSN-L)
- 2326-3660
- OpenAlex
- W2007235096
- Cited by
- 78
- References
- 10
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of Musculoskeletal Ultrasound to Assess and Quantify Muscle Glycogen Content. A Novel Approach. https://app.cochat.ai/papers/10.3810/psm.2014.09.2075
- The paper
- Hill, J. C., & Millán, I. S. (2014). Validation of Musculoskeletal Ultrasound to Assess and Quantify Muscle Glycogen Content. A Novel Approach. The Physician and Sportsmedicine. https://doi.org/10.3810/psm.2014.09.2075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.