Abstract

ABSTRACT PURPOSE: To test and demonstrate measurement precision, imaging resolution, 3D thickness mapping, and clinical utility of a new prototype 3D very high-frequency (VHF) (50 MHz) digital ultrasound scanning system for corneal epithelium, flap, and residual stromal thickness after laser in situ keratomileusis (LASIK). METHODS: VHF ultrasonic 3D data was acquired by arc-motion, meridional scanning within a 10-mm zone. Digital signal processing techniques provided high-resolution B-scan imaging, and I-scan traces for high-precision pachymetry in 4 eyes. Thickness maps of individual corneal layers were constructed. Reproducibility of epithelial, flap, and full corneal pachymetry was assessed for single-point and 3D thickness mapping by repeated measures. Thickness mapping of the epithelium, stroma, flap, and full cornea were determined before and after LASIK. Preoperative to postoperative difference maps for epithelium, flap, and stroma were produced to demonstrate anatomical changes in the thickness profile of each layer. RESULTS: Surface localization precision was 0.87 /im. Central reproducibility for single-point pachymetry of epithelium was 0.61 //m; flap, 1.14 /tra; and full cornea, 0.74 /im. Reproducibility for central pachymetry on 3D thickness mapping was 0.5 µt? for epithelium and 1.5-//m for full cornea. B-scans and 3D thickness maps after LASIK demonstrated resolution of epithelial, stromal component of the flap, and residual stromal layers. Large epithelial profile changes were demonstrated after LASIK. Topographic variability of flap thickness and residual stromal thickness were significant. CONCLUSIONS: VHF digital ultrasound arc-B scanning provides high-resolution imaging and high-precision three-dimensional thickness mapping of corneal layers, enabling accurate anatomical evaluation of the changes induced in the cornea by LASIK. [J Refract Surg 2000;16:414-4301

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3928/1081-597x-20000701-04

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 203

Metadata

Authors
Reinstein, D. Z., Silverman, R. H., Raevsky, T., Simoni, G. J., Lloyd, H. O., Najafi, D. J., Rondeau, M. J., & Coleman, D. J.
Venue
Journal of Refractive Surgery
Publisher
SLACK, Inc.
Published
2000-07
Volume
16
Issue
4
Pages
414-430
ISSN
  • 1042-962X (ISSN-L)
  • 1081-597X
OpenAlex
W2147454724
Cited by
203
References
0
FWCI
6.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Arc-scanning Very High-frequency Digital Ultrasound for 3D Pachymetric Mapping of the Corneal Epithelium and Stroma in Laser in situ Keratomileusis. https://app.cochat.ai/papers/10.3928/1081-597x-20000701-04
The paper
Reinstein, D. Z., Silverman, R. H., Raevsky, T., Simoni, G. J., Lloyd, H. O., Najafi, D. J., Rondeau, M. J., & Coleman, D. J. (2000). Arc-scanning Very High-frequency Digital Ultrasound for 3D Pachymetric Mapping of the Corneal Epithelium and Stroma in Laser in situ Keratomileusis. Journal of Refractive Surgery. https://doi.org/10.3928/1081-597x-20000701-04

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.