Central Corneal Volume and Endothelial Cell Count Following Femtosecond Laser–assisted Refractive Cataract Surgery Compared to Conventional Phacoemulsification
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare the effect of conventional phacoemulsification and femtosecond laser–assisted cataract surgery on the cornea using Scheimpflug imaging and noncontact specular microscopy. METHODS: In each group, 38 eyes (38 patients) underwent cataract surgery using either femtosecond laser–assisted (Alcon LenSx laser) (femtolaser group) or conventional phacoemulsification (phaco group). Central corneal thickness, 3-mm corneal volume, and Pentacam Nucleus Staging (PNS) were determined by a rotating Scheimpflug camera (Pentacam HR, Oculus Optikgeräte GmbH), and the volume stress index was calculated at 1 day and 1 month postoperatively. Endothelial cell count was measured by noncontact specular microscopy preoperatively, 1 day, 1 week, and 1 month postoperatively. RESULTS: Central corneal thickness was significantly higher in the phaco group (607±91 μm) than in the femtolaser group (580±42 μm) on day 1, but did not differ significantly preoperatively and at 1 week and 1 month. Volume stress index at day 1 was significantly lower in the femtolaser group than in the phaco group ( P <.05) but did not differ significantly at 1 month. Multivariate regression analysis showed that the type of surgery had a significant effect on central corneal thickness. CONCLUSIONS: Femtosecond laser–assisted cataract surgery causes less corneal swelling in the early postoperative period and may cause less trauma to corneal endothelial cells than manual phacoemulsification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery
Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20091117-04 · Cited by 563
Self-citationComparison of Intraocular Lens Decentration Parameters After Femtosecond and Manual Capsulotomies
Nagy, Z. Z., Kránitz, K., Takacs, A. I., Miháltz, K., Kovács, I., & Knorz, M. C. (2011) · Journal of Refractive Surgery · doi:10.3928/1081597x-20110607-01 · Cited by 268
Self-citationIncreased endothelial cell density in the paracentral and peripheral regionsof the human cornea
Amann, J., Holley, G. P., Lee, S.-B., & Edelhauser, H. F. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)02237-7 · Cited by 182
Hutchings, N., SIMPSON, T. L., Hyun, C., Moayed, A. A., Hariri, S., Sorbara, L., & Bizheva, K. K. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-4676 · Cited by 79
Free Radical Development in Phacoemulsification Cataract Surgery
Takahashi, H. (2005) · Journal of Nippon Medical School · doi:10.1272/jnms.72.4 · Cited by 65
Cited by
Toward Zero Effective Phacoemulsification Time Using Femtosecond Laser Pretreatment
Abell, R. G., Kerr, N. M., & Vote, B. J. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.11.045 · Cited by 235
Carbon footprint and cost–effectiveness of cataract surgery
Venkatesh, R., van Landingham, S. W., Khodifad, A. M., Haripriya, A., Thiel, C. L., Ramulu, P., & Robin, A. L. (2016) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000228 · Cited by 76
Metadata
- Authors
- Takács, Á. I., Kovács, I., Miháltz, K., Filkorn, T., Knorz, M. C., & Nagy, Z. Z.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2012-06
- Volume
- 28
- Issue
- 6
- Pages
- 387-392
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2115618973
- Cited by
- 177
- References
- 5
- FWCI
- 17.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Central Corneal Volume and Endothelial Cell Count Following Femtosecond Laser–assisted Refractive Cataract Surgery Compared to Conventional Phacoemulsification. https://app.cochat.ai/papers/10.3928/1081597x-20120508-02
- The paper
- Takács, Á. I., Kovács, I., Miháltz, K., Filkorn, T., Knorz, M. C., & Nagy, Z. Z. (2012). Central Corneal Volume and Endothelial Cell Count Following Femtosecond Laser–assisted Refractive Cataract Surgery Compared to Conventional Phacoemulsification. Journal of Refractive Surgery. https://doi.org/10.3928/1081597x-20120508-02
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.