Fireside Corrosion of Stainless and Low Alloyed Steels in a Waste-Fired CFB Boiler; The Effect of Adding Sulphur to the Fuel
Open accessThe DOI matches its Crossref record.
Abstract
Corrosion field tests have been carried out in the superheater region of a commercial waste-fired 75MW CFBC boiler using air cooled probes. Exposure time was 24 and 1000 hours. The effect of adding sulphur to the fuel on the corrosion of two high alloyed steels and a low alloyed steel was studied. The fuel consisted of 50% household waste and 50% industrial waste. The exposed samples were analyzed by ESEM/EDX and XRD. Metal loss was determined after 1000 hours. Both materials suffered significant corrosion in the absence of sulphur addition and the addition of sulphur to the fuel reduced corrosion significantly. The rapid corrosion of the high alloyed steel in the absence of sulphur addition is caused by the destruction of the chromiumcontaining protective oxide by formation of calcium chromate. Adding sulphur to the fuel inhibited chromate formation and increased the sulphate/chloride ratio in the deposit. Iron(II) chloride formed on the low alloyed steel regardless of whether sulphur was added or not.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alkali Induced High Temperature Corrosion of Stainless Steel: The Influence of NaCl, KCl and CaCl2
Karlsson, S., Pettersson, J., Johansson, L. G., & Svensson, J. E. (2012) · Oxidation of Metals · doi:10.1007/s11085-012-9293-7 · Cited by 118
Self-citationPettersson, J., Folkeson, N., Johansson, L.-G., & Svensson, J.-E. (2011) · Oxidation of Metals · doi:10.1007/s11085-011-9240-z · Cited by 117
Self-citationKarlsson, S., Åmand, L.-E., & Liske, J. (2015) · Fuel · doi:10.1016/j.fuel.2014.09.007 · Cited by 79
“This includes sulphur-based additives such as elemental sulphur (S) [15,22,24,25,28] and ammonium sulphate ((NH4)SO4) [24–26,29], sulphur recirculation [27] or by co-combustion of waste and biomass with coal, peat and municipal sewage sludge [21,23,26,30–33].”
BackgroundPhother-Simon, J., Hanif, I., Liske, J., & Jonsson, T. (2021) · Corrosion Science · doi:10.1016/j.corsci.2021.109315 · Cited by 37
Continuous KCl addition in high temperature exposures of 304 L – A way to mimic a boiler environment
Phother-Simon, J., Jonsson, T., & Liske, J. (2020) · Corrosion Science · doi:10.1016/j.corsci.2020.108511 · Cited by 25
Metadata
- Authors
- Folkeson, N., Pettersson, J., Pettersson, C., Johansson, L. G., Skog, E., Andersson, B. Å., Enestam, S., Tuiremo, J., Jonasson, A., Heikne, B., & Svensson, J. E.
- Venue
- Materials Science Forum
- Publisher
- Trans Tech Publications, Ltd.
- Published
- 2008-09-09
- Volume
- 595-598
- Pages
- 289-297
- ISSN
- 0255-5476 (ISSN-L)
- 1662-9752
- OpenAlex
- W2035412786
- Cited by
- 23
- References
- 0
- FWCI
- 3.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fireside Corrosion of Stainless and Low Alloyed Steels in a Waste-Fired CFB Boiler; The Effect of Adding Sulphur to the Fuel. https://app.cochat.ai/papers/10.4028/www.scientific.net/msf.595-598.289
- The paper
- Folkeson, N., Pettersson, J., Pettersson, C., Johansson, L. G., Skog, E., Andersson, B. Å., Enestam, S., Tuiremo, J., Jonasson, A., Heikne, B., & Svensson, J. E. (2008). Fireside Corrosion of Stainless and Low Alloyed Steels in a Waste-Fired CFB Boiler; The Effect of Adding Sulphur to the Fuel. Materials Science Forum. https://doi.org/10.4028/www.scientific.net/msf.595-598.289
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.