Real-World Improvements in Hypoglycemia in an Insulin-Dependent Cohort With Diabetes Mellitus Pre/Post Tandem Basal-Iq Technology Remote Software Update
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Objective: Software updatable insulin pumps, such as the t:slim X2 pump from Tandem Diabetes Care, enable access to new technology as soon as it is commercialized. The remote software update process allows for minimal interruption in therapy compared to purchasing a new pump, however little quantitative data exists on the software update process nor on pre/post therapeutic outcomes. We examined real-world usage and impact of a remote software updatable predictive low-glucose suspend (PLGS) technology designed to reduce hypoglycemic events in people with insulin-dependent diabetes. Methods: Approximately 15,000 U.S. Tandem pump users remotely updated their t:slim X2 software to Basal-IQ PLGS technology since its commercial release. We performed a retrospective analysis of users who uploaded at least 21 days of pre/post PLGS update usage data to the Tandem t:connect web application between August 28, 2018 and October 21, 2019 (n=6,170). Insulin delivery and sensor-glucose values were analyzed per recent international consensus and ADA guidelines. Software update performance was also assessed. Results: Median software update time was 5.36 minutes. Overall glycemic outcomes for pre and post software update showed a decrease in sensor time <70 mg/dL from 2.14 to 1.18% (-1.01, 95% CI -0.97, -1.05, p<0.001), with overall sensor time 70-180 mg/dL increasing from 57.8 to 58.5% (0.64, 95% CI 0.04, 1.24, p<0.001). These improvements were sustained at 3, 6 and 9 months after the update. Conclusion: Introduction of a software updatable PLGS algorithm for the Tandem t:slim X2 insulin pump resulted in sustained reductions of hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Economic Costs of Diabetes in the U.S. in 2017
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dci18-0007 · Cited by 2,528
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030
Self-citation6. Glycemic Targets: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s006 · Cited by 655
Evaluation of the Cascade of Diabetes Care in the United States, 2005-2016
Kazemian, P., Shebl, F. M., McCann, N., Walensky, R. P., & Wexler, D. J. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2019.2396 · Cited by 252
Forlenza, G. P., Li, Z., Buckingham, B. A., Pinsker, J. E., Cengiz, E., Wadwa, R. P., Ekhlaspour, L., Church, M. M., Weinzimer, S. A., Jost, E., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0771 · Cited by 246
Self-citation7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170
Choudhary, P., Olsen, B. S., Conget, I., Welsh, J. B., Vorrink, L., & Shin, J. J. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0324 · Cited by 118
Carlson, A. L., Kanapka, L. G., Miller, K. M., Ahmann, A. J., Chaytor, N. S., Fox, S., Kiblinger, L., Kruger, D., Levy, C. J., Peters, A. L., et al. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819894974 · Cited by 43
Cited by
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Real-World Patient-Reported Outcomes and Glycemic Results with Initiation of Control-IQ Technology
Pinsker, J. E., Müller, L., Constantin, A., Leas, S., Manning, M., McElwee Malloy, M., Singh, H., & Habif, S. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0388 · Cited by 147
Self-citationPinsker, J. E., Bartee, A., Katz, M., Lalonde, A., Jones, R., Dassau, E., & Wolpert, H. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0619 · Cited by 21
Self-citation
Metadata
- Authors
- Pinsker, J. E., Leas, S., Müller, L., & Habif, S.
- Venue
- Endocrine Practice
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 26
- Issue
- 7
- Pages
- 714-721
- ISSN
- 1530-891X (ISSN-L)
- OpenAlex
- W3010757859
- Cited by
- 22
- References
- 10
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-World Improvements in Hypoglycemia in an Insulin-Dependent Cohort With Diabetes Mellitus Pre/Post Tandem Basal-Iq Technology Remote Software Update. https://app.cochat.ai/papers/10.4158/ep-2019-0554
- The paper
- Pinsker, J. E., Leas, S., Müller, L., & Habif, S. (2020). Real-World Improvements in Hypoglycemia in an Insulin-Dependent Cohort With Diabetes Mellitus Pre/Post Tandem Basal-Iq Technology Remote Software Update. Endocrine Practice. https://doi.org/10.4158/ep-2019-0554
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.