The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Gating the mechanical channel Piezo1: A comparison between whole-cell and patch recording
Open accessAbstract
Piezo1 is a eukaryotic cation-selective mechanosensitive ion channel. To understand channel function in vivo, we first need to analyze and compare the response in the whole cell and the patch. In patches, Piezo1 inactivates and the current is fit well by a 3-state model with a single pressure-dependent rate. However, repeated stimulation led to an irreversible loss of inactivation. Remarkably, the loss of inactivation did not occur on a channel-by-channel basis but on all channels at the same time. Thus, the channels are in common mechanical domain. Divalent ions decreased the unitary conductance from ~68 pS to ~37 pS, irrespective of the cation species. Mg and Ca did not affect inactivation rates, but Zn caused a 3-fold slowing. CytochalasinD (cytoD) does not alter inactivation rates or the transition to the non-inactivating mode but does reduce the steady-state response. Whole-cell currents were similar to patch currents but also had significant differences. In contrast to the patch, cytoD inhibited the current suggesting that the activating forces were transmitted through the actin cytoskeleton. Hypotonic swelling that prestressed the cytoskeleton and the bilayer greatly increased the sensitivity of both control and cytoD cells so there are two pathways to transmit force to the channels. In contrast to patch, removing divalent ions decreased the whole-cell current. The difference between whole cell and patch properties provide new insights into our understanding of the Piezo1 gating mechanisms and cautions against generalization to in situ behavior.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316
The Mechanosensitive Ion Channel Piezo1 Is Inhibited by the Peptide GsMTx4
Bae, C., Sachs, F., & Gottlieb, P. A. (2011) · Biochemistry · doi:10.1021/bi200770q · Cited by 566
Self-citation
Cited by
Mechanically activated ion channel Piezo1 modulates macrophage polarization and stiffness sensing
Atcha, H., Jairaman, A., Holt, J. R., Meli, V. S., Nagalla, R. R., Veerasubramanian, P. K., Brumm, K. T., Lim, H. E., Othy, S., Cahalan, M. D., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23482-5 · Cited by 644
Piezos thrive under pressure: mechanically activated ion channels in health and disease
Murthy, S. E., Dubin, A. E., & Patapoutian, A. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.92 · Cited by 582
Touch, Tension, and Transduction – The Function and Regulation of Piezo Ion Channels
Wu, J., Lewis, A. H., & Grandl, J. (2017) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2016.09.004 · Cited by 570
Piezo1 Channels Are Inherently Mechanosensitive
Syeda, R., Florendo, M. N., Cox, C. D., Kefauver, J. M., Santos, J. S., Martinac, B., & Patapoutian, A. (2016) · Cell Reports · doi:10.1016/j.celrep.2016.10.033 · Cited by 532
Cox, C. D., Bae, C., Ziegler, L., Hartley, S., Nikolova-Krstevski, V., Rohde, P. R., Ng, C.-A., Sachs, F., Gottlieb, P. A., & Martinac, B. (2016) · Nature Communications · doi:10.1038/ncomms10366 · Cited by 528
Self-citationStructure-based membrane dome mechanism for Piezo mechanosensitivity
Guo, Y. R., & MacKinnon, R. (2017) · eLife · doi:10.7554/elife.33660 · Cited by 446
Mechanical sensitivity of Piezo1 ion channels can be tuned by cellular membrane tension
Lewis, A. H., & Grandl, J. (2015) · eLife · doi:10.7554/elife.12088 · Cited by 427
Albuisson, J., Murthy, S. E., Bandell, M., Coste, B., Louis-dit-Picard, H., Mathur, J., Fénéant-Thibault, M., Tertian, G., de Jaureguiberry, J.-P., Syfuss, P.-Y., et al. (2013) · Nature Communications · doi:10.1038/ncomms2899 · Cited by 377
Shi, Z., Graber, Z. T., Baumgart, T., Stone, H. A., & Cohen, A. E. (2018) · Cell · doi:10.1016/j.cell.2018.09.054 · Cited by 355
Piezo1 in Smooth Muscle Cells Is Involved in Hypertension-Dependent Arterial Remodeling
Retailleau, K., Duprat, F., Arhatte, M., Ranade, S. S., Peyronnet, R., Martins, J. R., Jodar, M., Moro, C., Offermanns, S., Feng, Y., et al. (2015) · Cell Reports · doi:10.1016/j.celrep.2015.09.072 · Cited by 355
Calcium-Permeable Ion Channels in Pain Signaling
Bourinet, E., Altier, C., Hildebrand, M. E., Trang, T., Salter, M. W., & Zamponi, G. W. (2014) · Physiological Reviews · doi:10.1152/physrev.00023.2013 · Cited by 337
Multiple clinical forms of dehydrated hereditary stomatocytosis arise from mutations in PIEZO1
Andolfo, I., Alper, S. L., De Franceschi, L., Auriemma, C., Russo, R., De Falco, L., Vallefuoco, F., Esposito, M. R., Vandorpe, D. H., Shmukler, B. E., et al. (2013) · Blood · doi:10.1182/blood-2013-02-482489 · Cited by 321
Xerocytosis is caused by mutations that alter the kinetics of the mechanosensitive channel PIEZO1
Bae, C., Gnanasambandam, R., Nicolai, C., Sachs, F., & Gottlieb, P. A. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1219777110 · Cited by 313
Self-citationRode, B., Shi, J., Endesh, N., Drinkhill, M. J., Webster, P. J., Lotteau, S. J., Bailey, M. A., Yuldasheva, N. Y., Ludlow, M. J., Cubbon, R. M., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00429-3 · Cited by 305
Tuning Piezo ion channels to detect molecular-scale movements relevant for fine touch
Poole, K., Herget, R., Lapatsina, L., Ngo, H.-D., & Lewin, G. R. (2014) · Nature Communications · doi:10.1038/ncomms4520 · Cited by 293
Mechanosensitive Ion Channels: Structural Features Relevant to Mechanotransduction Mechanisms
Jin, P., Jan, L. Y., & Jan, Y.-N. (2020) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-070918-050509 · Cited by 274
Rocio Servin-Vences, M., Moroni, M., Lewin, G. R., & Poole, K. (2017) · eLife · doi:10.7554/elife.21074 · Cited by 271
Calcium in Red Blood Cells—A Perilous Balance
Bogdanova, A., Makhro, A., Wang, J., Lipp, P., & Kaestner, L. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms14059848 · Cited by 262
Piezo Proteins: Regulators of Mechanosensation and Other Cellular Processes
Bagriantsev, S. N., Gracheva, E. O., & Gallagher, P. G. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.r114.612697 · Cited by 249
Piezo1 regulates mechanotransductive release of ATP from human RBCs
Cinar, E., Zhou, S., DeCourcey, J., Wang, Y., Waugh, R. E., & Wan, J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1507309112 · Cited by 206
Voltage gating of mechanosensitive PIEZO channels
Moroni, M., Servin-Vences, M. R., Fleischer, R., Sánchez-Carranza, O., & Lewin, G. R. (2018) · Nature Communications · doi:10.1038/s41467-018-03502-7 · Cited by 200
Suchyna, T. M. (2017) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2017.07.011 · Cited by 111
Endesh, N., Chuntharpursat‐Bon, E., Revill, C., Yuldasheva, N. Y., Futers, T. S., Parsonage, G., Humphreys, N., Adamson, A., Morley, L. C., Cubbon, R. M., et al. (2023) · Liver International · doi:10.1111/liv.15646 · Cited by 44
Magnetic nanomaterials for wireless thermal and mechanical neuromodulation
Signorelli, L., Hescham, S. A., Pralle, A., & Gregurec, D. (2022) · iScience · doi:10.1016/j.isci.2022.105401 · Cited by 32
Wang, Q., Peng, X., Chen, Y., Tang, X., Qin, Y., He, M., Chen, W., & Chen, H. (2023) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2023.02.043 · Cited by 24
Metadata
- Authors
- Gottlieb, P. A., Bae, C., & Sachs, F.
- Venue
- Channels
- Publisher
- Informa UK Limited
- Published
- 2012-07
- Volume
- 6
- Issue
- 4
- Pages
- 282-289
- ISSN
- 1933-6950 (ISSN-L)
- 1933-6969
- OpenAlex
- W2035330601
- Cited by
- 195
- References
- 2
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.