CoChat

Validation of the STOPBANG Questionnaire among Patients Referred for Suspected Obstructive Sleep Apnea

Open access
D. Chervin, Ronald · 2013 · Journal of Sleep Disorders: Treatment & Care
Cited by 107

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The STOP-BANG is a simple obstructive sleep apnea (OSA) screening tool, part questionnaire (STOP) and part demographic or physical measures (BANG), developed for use in preoperative surgical clinics. This study assessed sensitivity and specificity of the instrument among patients referred to a sleep disorders laboratory, and also its performance characteristics when BANG physical measures are patient-reported rather than measured. METHODS: Adults referred for diagnostic polysomnography completed the STOP questions and answered four yes/no questions (BANG self-reported) about their body mass index (weight and height), age, neck circumference, and gender, which were also assessed by laboratory technologists (BANG-measured). RESULTS: Among N=219 subjects (mean age 46.3 ± 13.9 [s.d.] years; 98 [44.8%] males) the sensitivity of the STOP-BANG measured for an apnea/hypopnea index (AHI, events per hour of sleep) >5, >15, and >30 was 82, 93, and 97% respectively. Corresponding negative predictive values were 44, 87, and 96%. Specificities were comparatively low (48, 40, and 33%). The STOP-BANG measured and STOP-BANG self-reported scores showed essentially equivalent test characteristics against polysomnography. CONCLUSIONS: The STOP-BANG appears to have limited utility in a referred, sleep laboratory setting. Negative results help to identify some individuals as unlikely to have moderate-to-severe apnea, and may thereby prove useful in identification of patients who would benefit more from laboratory studies than home studies. A STOP-BANG in which all information is self-reported may be as effective as the original version, and has potential to facilitate research or community screening where good negative predictive value is required for an effective screening tool.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4172/2325-9639.1000121

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 107

Metadata

Authors
D. Chervin, R.
Venue
Journal of Sleep Disorders: Treatment & Care
Published
2013
Volume
02
Issue
04
ISSN
2325-9639 (ISSN-L)
OpenAlex
W2011629460
Cited by
107
References
13
FWCI
6.73
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of the STOPBANG Questionnaire among Patients Referred for Suspected Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.4172/2325-9639.1000121
The paper
D. Chervin, R. (2013). Validation of the STOPBANG Questionnaire among Patients Referred for Suspected Obstructive Sleep Apnea. Journal of Sleep Disorders: Treatment & Care. https://doi.org/10.4172/2325-9639.1000121

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.