Practical Problems With Aerosol Therapy in COPD
The DOI matches its OpenAlex record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Inhaled aerosol drugs commonly used by patients with chronic obstructive pulmonary disease include short-acting and long-acting bronchodilators, as well as corticosteroids. These agents are available in a variety of inhaler devices, which include metered-dose inhalers (MDI), breath-actuated MDIs, nebulizers, and, currently, 5 different models of dry powder inhaler (DPI). There is evidence to suggest that multiple inhaler types cause confusion among patients and increase errors in patient use. Problems with MDIs include failure to coordinate inhalation with actuation of the MDI, inadequate breath-hold, and inappropriately fast inspiratory flow. Lack of a dose counter makes determining the number of remaining doses in an MDI problematic. Patient misuse of MDIs is compounded by lack of knowledge of correct use among health-care professionals. Several factors often seen with elderly patients have been identified as predictive of incorrect use of MDIs. These include mental-state scores, hand strength, and ideomotor dyspraxia. Holding chambers and spacers are partially intended to reduce the need for inhalation-actuation coordination with MDI use. However, such add-on devices can be subject to incorrect assembly. Possible delays between MDI actuation and inhalation, rapid inspiration, chamber electrostatic charge, and firing multiple puffs into the chamber can all reduce the availability of inhaled drug. Because they are breath-actuated, DPIs remove the need for inhalation-actuation synchrony, but there is evidence that patient errors in use of DPIs may be similar to those with MDIs. One of the biggest problems is loading and priming the DPI for use, and this may be due to the fact that every DPI model in current use is different. Medical personnel's knowledge of correct DPI use has also been shown to be lacking. The optimum inhalation profiles are different for the various DPIs, but, generally, chronic obstructive pulmonary disease patients have been shown to achieve a minimum therapeutic dose, although the inhaled amount may be suboptimal. A limitation of DPIs that have multidose powder reservoirs (eg, the Turbuhaler) is ambient humidity, which can reduce the released dose. Small-volume nebulizers are limited by bulk, treatment time, and variable performance, but are easy for patients to use. Important features identified by patients for an ideal inhaler are ease of use during an attack, dose counter, and general ease of use and learning. A breath-actuated-pMDI, such as the Autohaler, ranked at the top of inhaler preference in a study of 100 patients with airflow obstruction, compared to DPIs and MDIs. Short of a universal simple inhaler, patient and caregiver education remains the best solution to correct patient errors in use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
PAUWELS, R. A., BUIST, A. S., CALVERLEY, P. M. A., JENKINS, C. R., & HURD, S. S. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.5.2101039 · Cited by 6,587
Device Selection and Outcomes of Aerosol Therapy: Evidence-Based Guidelines
Dolovich, M. B., Ahrens, R. C., Hess, D. R., Anderson, P., Dhand, R., Rau, J. L., Smaldone, G. C., & Guyatt, G. (2005) · Chest · doi:10.1378/chest.127.1.335 · Cited by 794
Self-citationMisuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability
Giraud, V., & Roche, N. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00218402 · Cited by 538
Brocklebank, D., Ram, F., Wright, J., Barry, P., Cates, C., Davies, L., Douglas, G., Muers, M., Smith, D., & White, J. (2001) · Health Technology Assessment · doi:10.3310/hta5260 · Cited by 401
Problems With Inhaler Use: A Call for Improved Clinician and Patient Education
Fink, J. B., & Rubin, B. K. (2005) · Respiratory Care · doi:10.4187/respcare.05501360 · Cited by 358
Newman, S. P., Weisz, A. W., Talaee, N., & Clarke, S. W. (1991) · Thorax · doi:10.1136/thx.46.10.712 · Cited by 326
Influence of inspiratory flow rate upon the effect of a Turbuhaler.
Pedersen, S. S., Hansen, O. R., & Fuglsang, G. (1990) · Archives of Disease in Childhood · doi:10.1136/adc.65.3.308 · Cited by 270
Inappropriate inhaler use: assessment of use and patient preference of seven inhalation devices
LENNEY, J., INNES, J. A., & CROMPTON, G. K. (2000) · Respiratory Medicine · doi:10.1053/rmed.1999.0767 · Cited by 266
Multiple inhalers confuse asthma patients
van der Palen, J., Klein, J., van Herwaarden, C., Zielhuis, G., & Seydel, E. (1999) · European Respiratory Journal · doi:10.1183/09031936.99.14510349 · Cited by 219
The influence of age, diagnosis, and gender on proper use of metered-dose inhalers.
Goodman, D. E., Israel, E., Rosenberg, M., Johnston, R., Weiss, S. T., & Drazen, J. M. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.5.7952549 · Cited by 212
van Beerendonk, I., Mesters, I., Mudde, A. N., & Tan, T. D. (1998) · Journal of Asthma · doi:10.3109/02770909809068218 · Cited by 211
Dry Powder Aerosols I: A New Powder Inhalation Device
Bell, J. H., Hartley, P. S., & Cox, J. S. G. (1971) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.2600601028 · Cited by 202
De Blaquiere, P., Christensen, D. B., Carter, W. B., & Martin, T. R. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/140.4.910 · Cited by 185
McFadden, E. R. (1995) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(95)70206-7 · Cited by 146
van der Palen, J. A. M., Klein, J. J., Kerkhoff, A., & van Herwaarden, C. L. (1995) · Thorax · doi:10.1136/thx.50.11.1183 · Cited by 141
Chapman, K. R., Love, L. L., & Brubaker, H. (1993) · CHEST Journal · doi:10.1378/chest.104.5.1332 · Cited by 127
Characteristics Predicting Incorrect Metered-Dose Inhaler Technique in Older Subjects
Gray, S. L., Williams, D. M., Pulliam, C. C., Sirgo, M. A., Bishop, A. L., & Donohue, J. F. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440090084008 · Cited by 112
Ability to learn inhaler technique in relation to cognitive scores and tests of praxis in old age
Allen, S., & Ragab, S. Y. (2002) · Postgraduate Medical Journal · doi:10.1136/pmj.78.915.37 · Cited by 108
Diggory, P., Fernandez, C., Humphrey, A., Jones, V., & Murphy, M. (2001) · BMJ · doi:10.1136/bmj.322.7286.577 · Cited by 99
Misuse of Metered-dose Inhalers in Hospitalized Patients
Thompson, C. J., Irvine, M., Grathwohl, C. K., & Roth, M. B. (1994) · CHEST Journal · doi:10.1378/chest.105.3.715 · Cited by 86
Serra-Batllés, J., Plaza, V., Badiola, C., & Morejón, E. (2002) · Journal of Aerosol Medicine · doi:10.1089/08942680252908584 · Cited by 80
Home Nebulized Therapy for Patients with COPD
Corden, Z. M., Bosley, C., Rees, P. J., & Cochrane, G. M. (1997) · CHEST Journal · doi:10.1378/chest.112.5.1278 · Cited by 69
Burnell, P. K. P., Small, T., DOIG, S., Johal, B., Jenkins, R., & Gibson, G. J. (2001) · Respiratory Medicine · doi:10.1053/rmed.2001.1044 · Cited by 46 · cited 2×
“8 cm H2O.(56) Pedersen et al found that terbutaline delivered with a Turbuhaler was effective at flows as low as 30 L/min in asthmatic children, although improvement in forced expiratory volume in the first second (FEV1) was less at flows of 13 or 22 L/min.”
BackgroundInfluentialThorsson, L., & Geller, D. E. (2005) · Respiratory Medicine · doi:10.1016/j.rmed.2005.02.012 · Cited by 43
Moore, A. C., & Stone, S. (2004) · International Journal of Clinical Practice · doi:10.1111/j.1368-5031.2004.00123.x · Cited by 36
Balzano, G., BATTILORO, R., Biraghi, M. G., Stefanelli, F., Fuschillo, S., Gaudiosi, C., & Angelis, E. D. (2000) · Journal of Aerosol Medicine · doi:10.1089/jam.2000.13.25 · Cited by 21
Cited by
Inhaled drug therapy for treatment of tuberculosis
Misra, A., Hickey, A. J., Rossi, C., Borchard, G., Terada, H., Makino, K., Fourie, P. B., & Colombo, P. (2011) · Tuberculosis · doi:10.1016/j.tube.2010.08.009 · Cited by 172
“Effective uptake of rifampicin in a form of PLGA MS by the alveolar macrophage cell line NR8383.(24) Results after incubation for 12 h.”
MethodChoosing the right inhaler for your asthma or COPD patient
Usmani, O. S. (2019) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s160365 · Cited by 160
“Effective use of a DPI requires that each dose is primed and loaded in the correct manner.(40) DPIs derive the energy for emptying the drug system from the user’s inspiratory flow, and the failure to achieve a forceful inspiratory flow through a device is the most common critical mishandling error with DPIs, occurring…”
Background
Metadata
- Authors
- Rau, J. L.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2006-02-01
- Volume
- 51
- Issue
- 2
- Pages
- 158-172
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2121686558
- Cited by
- 173
- References
- 27
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.