CoChat

High-Flow Nasal Cannula Therapy in COVID-19: Using the ROX Index to Predict Success

Chandel, Abhimanyu, Patolia, Saloni, Brown, A Whitney, Collins, A Claire, Sahjwani, Dhwani, Khangoora, Vikramjit, Cameron, Paula C, Desai, Mehul, Kasarabada, Aditya, Kilcullen, Jack K, Nathan, Steven D, King, Christopher S · 2021 · Respiratory Care
Cited by 181

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Optimal timing of mechanical ventilation in COVID-19 is uncertain. We sought to evaluate outcomes of delayed intubation and examine the ROX index (ie, [ S pO 2 /F IO 2 ]/breathing frequency) to predict weaning from high-flow nasal cannula (HFNC) in patients with COVID-19. METHODS: We performed a multicenter, retrospective, observational cohort study of subjects with respiratory failure due to COVID-19 and managed with HFNC. The ROX index was applied to predict HFNC success. Subjects that failed HFNC were divided into early HFNC failure (≤ 48 h of HFNC therapy prior to mechanical ventilation) and late failure (> 48 h). Standard statistical comparisons and regression analyses were used to compare overall hospital mortality and secondary end points, including time-specific mortality, need for extracorporeal membrane oxygenation, and ICU length of stay between early and late failure groups. RESULTS: 272 subjects with COVID-19 were managed with HFNC. One hundred sixty-four (60.3%) were successfully weaned from HFNC, and 111 (67.7%) of those weaned were managed solely in non-ICU settings. ROX index >3.0 at 2, 6, and 12 hours after initiation of HFNC was 85.3% sensitive for identifying subsequent HFNC success. One hundred eight subjects were intubated for failure of HFNC (61 early failures and 47 late failures). Mortality after HFNC failure was high (45.4%). There was no statistical difference in hospital mortality (39.3% vs 53.2% , P = .18) or any of the secondary end points between early and late HFNC failure groups. This remained true even when adjusted for covariates. CONCLUSIONS: In this retrospective review, HFNC was a viable strategy and mechanical ventilation was unecessary in the majority of subjects. In the minority that progressed to mechanical ventilation, duration of HFNC did not differentiate subjects with worse clinical outcomes. The ROX index was sensitive for the identification of subjects successfully weaned from HFNC. Prospective studies in COVID-19 are warranted to confirm these findings and to optimize patient selection for use of HFNC in this disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.08631

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

Metadata

Authors
Chandel, A., Patolia, S., Brown, A. W., Collins, A. C., Sahjwani, D., Khangoora, V., Cameron, P. C., Desai, M., Kasarabada, A., Kilcullen, J. K., Nathan, S. D., & King, C. S.
Venue
Respiratory Care
Published
2021-06-01
Volume
66
Issue
6
Pages
909-919
ISSN
0020-1324 (ISSN-L)
OpenAlex
W3111429010
Cited by
181
References
21
FWCI
17.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.