Physiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
The DOI matches its OpenAlex record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess the physiological impact of the N95 filtering facepiece respirator (FFR) on healthcare workers. METHODS: Ten healthcare workers each conducted multiple 1-hour treadmill walking sessions, at 1.7 miles/h, and at 2.5 miles/h, while wearing FFR with exhalation valve, FFR without exhalation valve, and without FFR (control session). We monitored heart rate, respiratory rate, tidal volume, minute volume, blood oxygen saturation, and transcutaneously measured P(CO2). We also measured user comfort and exertion, FFR moisture retention, and the carbon dioxide and oxygen concentrations in the FFR's dead space. RESULTS: There were no significant differences between FFR and control in the physiological variables, exertion scores, or comfort scores. There was no significant difference in moisture retention between FFR with and without exhalation valve. Two subjects had peak P(CO2) > or = 50 mm Hg. The FFR with exhalation valve offered no benefit in physiological burden over the FFR without valve. The FFR dead-space oxygen and carbon dioxide levels did not meet the Occupational Safety and Health Administration's ambient workplace standards. CONCLUSIONS: In healthy healthcare workers, FFR did not impose any important physiological burden during 1 hour of use, at realistic clinical work rates, but the FFR dead-space carbon dioxide and oxygen levels were significantly above and below, respectively, the ambient workplace standards, and elevated P(CO2) is a possibility. Exhalation valve did not significantly ameliorate the FFR's P(CO2) impact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497
Borg's Perceived Exertion and Pain Scales
Borg, G. A. V. (1998) · Cited by 3,366
Li, Y., Tokura, H., Guo, Y. P., Wong, A. S. W., Wong, T., Chung, J., & Newton, E. (2005) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-004-0584-4 · Cited by 364
Anderson, C. A., Anderson, K. B., & Deuser, W. E. (1996) · Personality and Social Psychology Bulletin · doi:10.1177/0146167296224004 · Cited by 254
Respirator Tolerance in Health Care Workers
Radonovich, L. J. (2009) · JAMA · doi:10.1001/jama.2008.894 · Cited by 217
Eberhard, P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278642.16117.f8 · Cited by 161
In vivo protective performance of N95 respirator and surgical facemask
Li, Y., Wong, T., Chung, J., Guo, Y. P., Hu, J. Y., Guan, Y. T., Yao, L., Song, Q. W., & Newton, E. (2006) · American Journal of Industrial Medicine · doi:10.1002/ajim.20395 · Cited by 159
Monitoring of Ventilation During Exercise by a Portable Respiratory Inductive Plethysmograph
Clarenbach, C. F., Senn, O., Brack, T., Kohler, M., & Bloch, K. E. (2005) · Chest · doi:10.1378/chest.128.3.1282 · Cited by 140
Dynamic dead space in face masks used with noninvasive ventilators: a lung model study
Saatci, E., Miller, D. M., Stell, I. M., Lee, K. C., & Moxham, J. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00039503 · Cited by 125
Kaye, J., Buchanan, F., Kendrick, A., Johnson, P., Lowry, C., Bailey, J., Nutt, D., & Lightman, S. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 121
Cited by
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064
Rebmann, T., Carrico, R., & Wang, J. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2013.02.017 · Cited by 269
Commentary: Physiological and Psychological Impact of Face Mask Usage during the COVID-19 Pandemic
Scheid, J. L., Lupien, S. P., Ford, G. S., & West, S. L. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17186655 · Cited by 259
Health Effects of Wildfire Smoke in Children and Public Health Tools: A Narrative Review
Holm, S. M., Miller, M. D., & Balmes, J. R. (2021) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-020-00267-4 · Cited by 246
“Ten healthcare workers had no differences in physiologic measures during an hour of treadmill walking with a filtering facepiece respirator, compared to without [82].”
Return to training in the COVID‐19 era: The physiological effects of face masks during exercise
Epstein, D., Korytny, A., Isenberg, Y., Marcusohn, E., Zukermann, R., Bishop, B., Minha, S., Raz, A., & Miller, A. (2021) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.13832 · Cited by 245
Roberge, R. J., Kim, J.-H., & Benson, S. M. (2012) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2012.01.010 · Cited by 185
Self-citationKisielinski, K., Giboni, P., Prescher, A., Klosterhalfen, B., Graessel, D., Funken, S., Kempski, O., & Hirsch, O. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18084344 · Cited by 169
“These phenomena are responsible for a statistically significant increase in carbon dioxide (CO2) blood content in mask wearers [19,20], on the one hand, measured transcutaneously via an increased PtcCO2 value [15,17,19,21,22], on the other hand, via endexpiratory partial pressure of carbon dioxide (PETCO2) [23,24] or,…”
BackgroundInfluentialSmart facemask for wireless CO2 monitoring
Escobedo, P., Fernández-Ramos, M. D., López-Ruiz, N., Moyano-Rodríguez, O., Martínez-Olmos, A., Pérez de Vargas-Sansalvador, I. M., Carvajal, M. A., Capitán-Vallvey, L. F., & Palma, A. J. (2022) · Nature Communications · doi:10.1038/s41467-021-27733-3 · Cited by 164
Masks and Face Coverings for the Lay Public: A Narrative Update
Czypionka, T., Greenhalgh, T., Bassler, D., & Bryant, M. B. (2021) · Annals of Internal Medicine · doi:10.7326/m20-6625 · Cited by 82
Metadata
- Authors
- Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2010-05-01
- Volume
- 55
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2164438961
- Cited by
- 276
- References
- 26
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.