Physiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Abstract
OBJECTIVE: To assess the physiological impact of the N95 filtering facepiece respirator (FFR) on healthcare workers. METHODS: Ten healthcare workers each conducted multiple 1-hour treadmill walking sessions, at 1.7 miles/h, and at 2.5 miles/h, while wearing FFR with exhalation valve, FFR without exhalation valve, and without FFR (control session). We monitored heart rate, respiratory rate, tidal volume, minute volume, blood oxygen saturation, and transcutaneously measured P(CO2). We also measured user comfort and exertion, FFR moisture retention, and the carbon dioxide and oxygen concentrations in the FFR's dead space. RESULTS: There were no significant differences between FFR and control in the physiological variables, exertion scores, or comfort scores. There was no significant difference in moisture retention between FFR with and without exhalation valve. Two subjects had peak P(CO2) > or = 50 mm Hg. The FFR with exhalation valve offered no benefit in physiological burden over the FFR without valve. The FFR dead-space oxygen and carbon dioxide levels did not meet the Occupational Safety and Health Administration's ambient workplace standards. CONCLUSIONS: In healthy healthcare workers, FFR did not impose any important physiological burden during 1 hour of use, at realistic clinical work rates, but the FFR dead-space carbon dioxide and oxygen levels were significantly above and below, respectively, the ambient workplace standards, and elevated P(CO2) is a possibility. Exhalation valve did not significantly ameliorate the FFR's P(CO2) impact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497
Borg's Perceived Exertion and Pain Scales
Borg, G. A. V. (1998) · Cited by 3,366
Li, Y., Tokura, H., Guo, Y. P., Wong, A. S. W., Wong, T., Chung, J., & Newton, E. (2005) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-004-0584-4 · Cited by 364
Anderson, C. A., Anderson, K. B., & Deuser, W. E. (1996) · Personality and Social Psychology Bulletin · doi:10.1177/0146167296224004 · Cited by 254
Respirator Tolerance in Health Care Workers
Radonovich, L. J. (2009) · JAMA · doi:10.1001/jama.2008.894 · Cited by 217
In vivo protective performance of N95 respirator and surgical facemask
Li, Y., Wong, T., Chung, J., Guo, Y. P., Hu, J. Y., Guan, Y. T., Yao, L., Song, Q. W., & Newton, E. (2006) · American Journal of Industrial Medicine · doi:10.1002/ajim.20395 · Cited by 159
Eberhard, P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000278642.16117.f8 · Cited by 143
Monitoring of Ventilation During Exercise by a Portable Respiratory Inductive Plethysmograph
Clarenbach, C. F., Senn, O., Brack, T., Kohler, M., & Bloch, K. E. (2005) · Chest · doi:10.1378/chest.128.3.1282 · Cited by 140
Kaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134
Dynamic dead space in face masks used with noninvasive ventilators: a lung model study
Saatci, E., Miller, D. M., Stell, I. M., Lee, K. C., & Moxham, J. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00039503 · Cited by 125
THE PHYSIOLOGICAL COST OF WEARING A DISPOSABLE RESPIRATOR
Jones, J. G. (1991) · American Industrial Hygiene Association Journal · doi:10.1080/15298669191364631 · Cited by 102
Measurement of exercise ventilation by a portable respiratory inductive plethysmograph
Witt, J. D. S., Fisher, J. R. K. O., Guenette, J. A., Cheong, K. A., Wilson, B. J., & Sheel, A. W. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.01.010 · Cited by 78
Respiratory inductive plethysmography to assess respiratory variability and complexity in humans
Fiamma, M., Samara, Z., Baconnier, P., Similowski, T., & Straus, C. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.12.001 · Cited by 74
Kao, T., Huang, K.-C., Huang, Y., Tsai, T., Hsieh, B.-S., & Wu, M. (2004) · PubMed · Cited by 67
Rosner, V., Hannhart, B., Chabot, F., & Polu, J. M. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.13e18.x · Cited by 57
What do healthcare workers think? A survey of facial protection equipment user preferences
Bryce, E., Forrester, L., Scharf, S., & Eshghpour, M. (2008) · Journal of Hospital Infection · doi:10.1016/j.jhin.2007.12.007 · Cited by 51
Evaluation of the Efficiency of Medical Masks and the Creation of New Medical Masks
Huang, J., & Huang, V. (2007) · Journal of International Medical Research · doi:10.1177/147323000703500205 · Cited by 43
Guo, Y. P., Li, Y., Tokura, H., Wong, T. K. S., Chung, J. W. Y., Gohel, M. D. I., Leung, P. H. M., & Newton, E. W. (2008) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.2114/jpa2.27.93 · Cited by 41
Sridhar, M. K., Carter, R., Moran, F., & Banham, S. W. (1993) · Thorax · doi:10.1136/thx.48.6.643 · Cited by 41
Stege, G., van den Elshout, F. J. J., Heijdra, Y. F., van de Ven, M. J. T., Dekhuijzen, P. N. R., & Vos, P. J. E. (2008) · Respiration · doi:10.1159/000187631 · Cited by 39
Carter, R., & Banham, S. W. (2000) · Respiratory Medicine · doi:10.1053/rmed.1999.0714 · Cited by 37
Multidomain Subjective Response to Respirator Use During Simulated Work
Harber, P. I., Bansal, S., Santiago, S., Liu, D., Yun, D., Ng, D., Liu, Y., & Wu, S. (2009) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0b013e31817f458b · Cited by 26
PHYSIOLOGIC AND SUBJECTIVE EFFECTS OF RESPIRATOR MASK TYPE
Harber, P. I., Beck, J. C., Brown, C., & Luo, J. S. (1991) · American Industrial Hygiene Association Journal · doi:10.1080/15298669191364875 · Cited by 25
Arterial blood gases during exercise: Validity of transcutaneous measurements
Planès, C., Leroy, M., Foray, E., & Raffestin, B. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.26248 · Cited by 19
Ks, K., Kee, W. D. N., Tam, Y., Wong, M. K., & Lee, S. W. Y. (2008) · PubMed · Cited by 11
Unmanned Assessment of Respirator Carbon Dioxide Levels: Comparison of Methods of Measurement
Caretti, D. M., & Coyne, K. M. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620801969998 · Cited by 10
Cited by
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064
Rebmann, T., Carrico, R., & Wang, J. (2013) · American Journal of Infection Control · doi:10.1016/j.ajic.2013.02.017 · Cited by 269
Commentary: Physiological and Psychological Impact of Face Mask Usage during the COVID-19 Pandemic
Scheid, J. L., Lupien, S. P., Ford, G. S., & West, S. L. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17186655 · Cited by 259
Health Effects of Wildfire Smoke in Children and Public Health Tools: A Narrative Review
Holm, S. M., Miller, M. D., & Balmes, J. R. (2021) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-020-00267-4 · Cited by 246
Masks and Face Coverings for the Lay Public: A Narrative Update
Czypionka, T., Greenhalgh, T., Bassler, D., & Bryant, M. B. (2021) · Annals of Internal Medicine · doi:10.7326/m20-6625 · Cited by 82
Metadata
- Authors
- Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2010-05-01
- Volume
- 55
- Issue
- 5
- Pages
- 569-577
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2164438961
- Cited by
- 276
- References
- 26
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.