CoChat

Clinical decisions support malfunctions in a commercial electronic health record

Open access
Yackel, Thomas R., Gorman, Paul N., Dorr, David A., Kassakian, Steven Z. · 2017 · Applied Clinical Informatics
Cited by 37

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Summary: Objectives: Determine if clinical decision support (CDS) malfunctions occur in a commercial electronic health record (EHR) system, characterize their pathways and describe methods of detection. Methods: We retrospectively examined the firing rate for 226 alert type CDS rules for detection of anomalies using both expert visualization and statistical process control (SPC) methods over a five year period. Candidate anomalies were investigated and validated. Results: Twenty-one candidate CDS anomalies were identified from 8,300 alert-months. Of these candidate anomalies, four were confirmed as CDS malfunctions, eight as false-positives, and nine could not be classified. The four CDS malfunctions were a result of errors in knowledge management: 1) inadvertent addition and removal of a medication code to the electronic formulary list; 2) a seasonal alert which was not activated; 3) a change in the base data structures; and 4) direct editing of an alert related to its medications. 154 CDS rules (68%) were amenable to SPC methods and the test characteristics were calculated as a sensitivity of 95%, positive predictive value of 29% and F-measure 0.44. Discussion: CDS malfunctions were found to occur in our EHR. All of the pathways for these malfunctions can be described as knowledge management errors. Expert visualization is a robust method of detection, but is resource intensive. SPC-based methods, when applicable, perform reasonably well retrospectively. Conclusion: CDS anomalies were found to occur in a commercial EHR and visual detection along with SPC analysis represents promising methods of malfunction detection. Citation: Kassakian SZ, Yackel TR, Gorman PN, Dorr DA. Clinical decisions support malfunctions in a commercial electronic health record. Appl Clin Inform 2017; 8: 910–923 https://doi.org/10.4338/ACI-2017-01-RA-0006

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4338/aci-2017-01-ra-0006

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 37

Metadata

Authors
Yackel, T. R., Gorman, P. N., Dorr, D. A., & Kassakian, S. Z.
Venue
Applied Clinical Informatics
Published
2017-07
Volume
08
Issue
03
Pages
910-923
ISSN
1869-0327 (ISSN-L)
OpenAlex
W2753858911
Cited by
37
References
9
FWCI
6.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.