The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Usability and Safety in Electronic Medical Records Interface Design: A Review of Recent Literature and Guideline Formulation
Abstract
Objective: The objectives of this study were to (a) review electronic medical record (EMR) and related electronic health record (EHR) interface usability issues, (b) review how EMRs have been evaluated with safety analysis techniques along with any hazard recognition, and (c) formulate design guidelines and a concept for enhanced EMR interfaces with a focus on diagnosis and documentation processes. Background: A major impact of information technology in health care has been the introduction of EMRs. Although numerous studies indicate use of EMRs to increase health care quality, there remain concerns with usability issues and safety. Method: A literature search was conducted using Compendex, PubMed, CINAHL, and Web of Science databases to find EMR research published since 2000. Inclusion criteria included relevant English-language papers with subsets of keywords and any studies (manually) identified with a focus on EMR usability. Results: Fifty studies met the inclusion criteria. Results revealed EMR and EHR usability problems to include violations of natural dialog, control consistency, effective use of language, effective information presentation, and customization principles as well as a lack of error prevention, minimization of cognitive load, and feedback. Studies focusing on EMR system safety made no objective assessments and applied only inductive reasoning methods for hazard recognition. Conclusion: On the basis of the identified usability problems and structure of safety analysis techniques, we provide EMR design guidelines and a design concept focused on the diagnosis process and documentation. Application: The design guidelines and new interface concept can be used for prototyping and testing enhanced EMRs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The magical number seven, plus or minus two: Some limits on our capacity for processing information.
Miller, G. A. (1956) · Psychological Review · doi:10.1037/h0043158 · Cited by 17,812
The magical number seven, plus or minus two: Some limits on our capacity for processing information.
Miller, G. A. (1994) · Psychological Review · doi:10.1037/0033-295x.101.2.343 · Cited by 17,161
Chaudhry, B., Wang, J., Wu, S., Maglione, M., Mojica, W., Roth, E., Morton, S. C., & Shekelle, P. G. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-10-200605160-00125 · Cited by 3,159
A new accident model for engineering safer systems
Leveson, N. (2004) · Safety Science · doi:10.1016/s0925-7535(03)00047-x · Cited by 2,243
Improving Safety with Information Technology
Bates, D. W., & Gawande, A. A. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa020847 · Cited by 1,544
Use of Electronic Health Records in U.S. Hospitals
Jha, A. K., DesRoches, C. M., Campbell, E. G., Donelan, K., Rao, S. R., Ferris, T. G., Shields, A., Rosenbaum, S., & Blumenthal, D. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0900592 · Cited by 1,473
Improving a human-computer dialogue
Molich, R., & Nielsen, J. (1990) · Communications of the ACM · doi:10.1145/77481.77486 · Cited by 815
The Proximity Compatibility Principle: Its Psychological Foundation and Relevance to Display Design
Wickens, C. D., & Carswell, C. M. (1995) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872095779049408 · Cited by 655
Informatics in Primary Care: Strategies in Information Management for the Healthcare Provider
(2002) · Health Informatics · doi:10.1007/978-1-4613-0069-4 · Cited by 422
(2013) · Europe PMC (PubMed Central) · Cited by 396
Research works printed but not linked: 12
- Bowman S., 2013, Perspectives in Health Information Management, 10, 1c
- Chin B., 2012, Hawaii Journal of Medicine and Public Health, 71, 50
- Graham T. A., 2008, AMIA annual symposium proceedings, 2008, 257
- Hagstedt L. J., 2011, Informatics in Primary Care, 19, 161
- Harrington C., 2011, AMIA annual symposium proceedings, 2011, 549
- Indranoi C., 2009, In Proceedings of the 2009 Industrial Engineering Research Conference, 797
- International Organization for Standardization, 1998, Ergonomic requirements for office work with visual display terminals (VDTs) — Part 11: Guidance on usability
- Jaspers M. W., 2008, Studies in Health Technology and Informatics, 136, 303
- Omdahl T. P., 1988, Reliability, availability, and maintainability dictionary
- Singh R., 2004, Informatics in Primary Care, 12, 235
- Suebnukran S., 2013, SpringPlus, 2, 1
- Zheng K., 2007, Studies in Health Technology and Informatics, 129, 1058
Cited by
Association of Electronic Health Record Design and Use Factors With Clinician Stress and Burnout
Kroth, P. J., Morioka-Douglas, N., Veres, S., Babbott, S., Poplau, S., Qeadan, F., Parshall, C., Corrigan, K., & Linzer, M. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.9609 · Cited by 333
Identifying electronic health record usability and safety challenges in pediatric settings
Ratwani, R. M., Savage, E., Will, A., Fong, A., Karavite, D., Muthu, N., Rivera, A. J., Gibson, C., Asmonga, D., Moscovitch, B., et al. (2018) · Health Affairs · doi:10.1377/hlthaff.2018.0699 · Cited by 163
Navigation in the electronic health record: A review of the safety and usability literature
Roman, L. C., Ancker, J. S., Johnson, S. B., & Senathirajah, Y. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.01.005 · Cited by 163
Why Is the Electronic Health Record So Challenging for Research and Clinical Care?
Holmes, J. H., Beinlich, J., Boland, M. R., Bowles, K. H., Chen, Y., Cook, T. S., Demiris, G., Draugelis, M. E., Fluharty, L., Gabriel, P. E., et al. (2021) · Methods of Information in Medicine · doi:10.1055/s-0041-1731784 · Cited by 164
Melnick, E. R., Harry, E. M., Sinsky, C. A., Dyrbye, L. N., Wang, H., Trockel, M., West, C. P., & Shanafelt, T. D. (2020) · Journal of Medical Internet Research · doi:10.2196/23382 · Cited by 120
Metadata
- Authors
- Zahabi, M., Kaber, D. B., & Swangnetr, M.
- Affiliations
- North Carolina State University (US)
- Khon Kaen University, Khon Kaen, Thailand
- Venue
- Human Factors: The Journal of the Human Factors and Ergonomics Society
- Publisher
- SAGE Publications
- Published
- 2015-03-23
- Volume
- 57
- Issue
- 5
- Pages
- 805-834
- ISSN
- 0018-7208 (ISSN-L)
- 1547-8181
- OpenAlex
- W2153072644
- Semantic Scholar
- 337add3ca4224d5d4244772ae3b95bba6f06cf97
- Cited by
- 240
- References
- 76
- Citations by year
- 2026: 21 · 2025: 16 · 2024: 17 · 2023: 17 · 2022: 21 · 2021: 35 · 2020: 33 · 2019: 26 · 2018: 16 · 2017: 23 · 2016: 14 · 2015: 1
- FWCI
- 34.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Human Factors The Journal of the Human Factors and Ergonomics Society (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (2 T42 OH008673-08)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
- Health Sciences › Nursing › Research and Theory › Nursing Diagnosis and Documentation
- Keywords
- electronic health records, user interface usability, medical device safety, hazard identification, design guidelines, error prevention, cognitive load, feedback, clinical documentation, diagnostic process, data presentation
- MeSH terms
- Humans, Quality of Health Care, Safety, Software, User-Computer Interface, Guidelines as Topic, Medical Errors, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Usability and Safety in Electronic Medical Records Interface Design: A Review of Recent Literature and Guideline Formulation. https://app.cochat.ai/papers/10.1177/0018720815576827
- The paper
- Zahabi, M., Kaber, D. B., & Swangnetr, M. (2015). Usability and Safety in Electronic Medical Records Interface Design: A Review of Recent Literature and Guideline Formulation. Human Factors: The Journal of the Human Factors and Ergonomics Society. https://doi.org/10.1177/0018720815576827
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.