How can we best detect atrial fibrillation?
The DOI matches its OpenAlex record.
Abstract
Atrial fibrillation (AF) is an arrhythmia of increasing prevalence associated with a reducible risk of stroke. We conducted a systematic review to address five questions relating to how we can best detect AF: 1. Are there useful screening tests to determine who should have a 12-lead electrocardiogram (ECG)? Potential screening tests, all with acceptable sensitivity, include pulse palpation, single-lead ECG and newer technologies such as modified sphygmomanometers or a finger probe device. Pulse palpation has a high number of false positives, but is the cheapest method. 2. Is it more effective to offer 12-lead ECGs to the whole population (or specific sub-groups) or only to those who screen positive for AF? The cost-effectiveness of new devices, such as a modified blood pressure monitor, needs to be assessed. It is more cost-effective to opportunistically screen people rather than to offer a 12-lead ECG to everybody. 3. How accurate are different healthcare professionals and interpretative software at diagnosing AF on ECG? Definitive diagnosis of AF should be by 12-lead ECG, interpreted by someone with appropriate expertise. Computer software is not currently sensitive enough to be used alone to diagnose AF on ECG. Primary care practitioners may not accurately detect AF on ECG, but consistently high accuracy can be achieved by healthcare professionals with adequate training. 4. How best can we diagnose paroxysmal atrial fibrillation (PAF)? In patients in whom PAF is suspected, longer periods of monitoring will detect more cases of PAF. 5. What is the impact of the use of different ECG monitoring strategies (e.g. Holter monitoring, serial ECGs, continuous ECG) on AF detection rates post-stroke? In patients post-stroke, a single ECG will miss cases of PAF which can be detected by longer duration monitoring such as Holter monitoring, cardiac event recorders and serial ECGs. Further research into the cost-effectiveness of these methods, the duration of monitoring required and the clinical significance of the PAF detected is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Asgari, S., Mehrnia, A., & Moussavi, M. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.03.005 · Cited by 241
Kearley, K., Selwood, M., Van den Bruel, A., Thompson, M., Mant, D., Hobbs, F. R., Fitzmaurice, D., & Heneghan, C. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-004565 · Cited by 106
The diagnostic accuracy of the MyDiagnostick to detect atrial fibrillation in primary care
Vaes, B., Stalpaert, S., Tavernier, K., Thaels, B., Lapeire, D., Mullens, W., & Degryse, J. (2014) · BMC Family Practice · doi:10.1186/1471-2296-15-113 · Cited by 81
“Palpation of the pulse, to monitor the heart rate, has a good sensitivity but a low specificity, making this a useful method of ruling out atrial fibrillation but a less good method of confirming it [11].”
BackgroundMethodHow will machine learning inform the clinical care of atrial fibrillation?
Siontis, K. C., Yao, X., Pirruccello, J. P., Philippakis, A. A., & Noseworthy, P. A. (2020) · Circulation Research · doi:10.1161/circresaha.120.316401 · Cited by 61
Park, S.-H., June, K. J., & Choi, Y.-K. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2019.1620102 · Cited by 6
Metadata
- Authors
- Harris, K., Edwards, D., & Mant, J.
- Venue
- PubMed
- Publisher
- National Institutes of Health
- Published
- 2012-01-01
- Volume
- 42 Suppl 18
- Pages
- 5-22
- OpenAlex
- W96439756
- Cited by
- 61
- References
- 0
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.