Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Low-cost particulate matter (PM) sensors are promising tools for supplementing existing air quality monitoring networks. However, the performance of the new generation of low-cost PM sensors under field conditions is not well understood. In this study, we characterized the performance capabilities of a new low-cost PM sensor model (Plantower model PMS3003) for measuring PM2.5 at 1 min, 1 h, 6 h, 12 h, and 24 h integration times. We tested the PMS3003 sensors in both low-concentration suburban regions (Durham and Research Triangle Park (RTP), NC, US) with 1 h PM2.5 (mean ± SD) of 9±9 and 10±3 µg m−3, respectively, and a high-concentration urban location (Kanpur, India) with 1 h PM2.5 of 36±17 and 116±57 µg m−3 during monsoon and post-monsoon seasons, respectively. In Durham and Kanpur, the sensors were compared to a research-grade instrument (environmental β attenuation monitor, E-BAM) to determine how these sensors perform across a range of PM2.5 concentrations and meteorological factors (e.g., temperature and relative humidity, RH). In RTP, the sensors were compared to three Federal Equivalent Methods (FEMs) including two Teledyne model T640s and a Thermo Scientific model 5030 SHARP to demonstrate the importance of the type of reference monitor selected for sensor calibration. The decrease in 1 h mean errors of the calibrated sensors using univariate linear models from Durham (201 %) to Kanpur monsoon (46 %) and post-monsoon (35 %) seasons showed that PMS3003 performance generally improved as ambient PM2.5 increased. The precision of reference instruments (T640: ±0.5 µg m−3 for 1 h; SHARP: ±2 µg m−3 for 24 h, better than the E-BAM) is critical in evaluating sensor performance, and β-attenuation-based monitors may not be ideal for testing PM sensors at low concentrations, as underscored by (1) the less dramatic error reduction over averaging times in RTP against optically based T640 (from 27 % for 1 h to 9 % for 24 h) than in Durham (from 201 % to 15 %); (2) the lower errors in RTP than the Kanpur post-monsoon season (from 35 % to 11 %); and (3) the higher T640–PMS3003 correlations (R2≥0.63) than SHARP–PMS3003 (R2≥0.25). A major RH influence was found in RTP (1 h RH =64±22 %) due to the relatively high precision of the T640 measurements that can explain up to ∼30 % of the variance in 1 min to 6 h PMS3003 PM2.5 measurements. When proper RH corrections are made by empirical nonlinear equations after using a more precise reference method to calibrate the sensors, our work suggests that the PMS3003 sensors can measure PM2.5 concentrations within ∼10 % of ambient values. We observed that PMS3003 sensors appeared to exhibit a nonlinear response when ambient PM2.5 exceeded ∼125 µg m−3 and found that the quadratic fit is more appropriate than the univariate linear model to capture this nonlinearity and can further reduce errors by up to 11 %. Our results have substantial implications for how variability in ambient PM2.5 concentrations, reference monitor types, and meteorological factors can affect PMS3003 performance characterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Health Effects of Fine Particulate Air Pollution: Lines that Connect
Pope, C. A., & Dockery, D. W. (2006) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2006.10464485 · Cited by 6,583
On optimal and data-based histograms
SCOTT, D. W. (1979) · Biometrika · doi:10.1093/biomet/66.3.605 · Cited by 1,819
The Changing Paradigm of Air Pollution Monitoring
Snyder, E. G., Watkins, T. H., Solomon, P. A., Thoma, E. D., Williams, R. W., Hagler, G. S. W., Shelow, D., Hindin, D. A., Kilaru, V. J., & Preuss, P. W. (2013) · Environmental Science & Technology · doi:10.1021/es4022602 · Cited by 974
Chow, J. C. (1995) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1995.10467369 · Cited by 701
Zimmerman, N., Presto, A. A., Kumar, S. P. N., Gu, J., Hauryliuk, A., Robinson, E. S., Robinson, A. L., & Subramanian, R. (2018) · Atmospheric Measurement Techniques · doi:10.5194/amt-11-291-2018 · Cited by 566
Ambient and laboratory evaluation of a low-cost particulate matter sensor
Kelly, K. E., Whitaker, J., Petty, A., Widmer, C., Dybwad, A., Sleeth, D., Martin, R., & Butterfield, A. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2016.12.039 · Cited by 498
Jiao, W., Hagler, G., Williams, R., Sharpe, R., Brown, R., Garver, D., Judge, R., Caudill, M., Rickard, J., Davis, M., et al. (2016) · Atmospheric Measurement Techniques · doi:10.5194/amt-9-5281-2016 · Cited by 484
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471
Gao, M., Cao, J., & Seto, E. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.01.013 · Cited by 345
Cross, E. S., Williams, L. R., Lewis, D. K., Magoon, G. R., Onasch, T. B., Kaminsky, M. L., Worsnop, D. R., & Jayne, J. T. (2017) · Atmospheric Measurement Techniques · doi:10.5194/amt-10-3575-2017 · Cited by 317
Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
Holstius, D. M., Pillarisetti, A., Smith, K. R., & Seto, E. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-1121-2014 · Cited by 312
Optical characteristics of atmospheric aerosols
Waggoner, A. P., Weiss, R. E., Ahlquist, N. C., Covert, D. S., Will, S., & Charlson, R. J. (1981) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(81)90224-9 · Cited by 307
Aitkin, M., Francis, B., Hinde, J., & Darnell, R. (2009) · doi:10.1093/oso/9780199219148.001.0001 · Cited by 277
Chakrabarti, B., Fine, P. M., Delfino, R., & Sioutas, C. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.03.007 · Cited by 186
Hagler, G. S. W., Bergin, M. H., Salmon, L. G., Yu, J. Z., Wan, E. C. H., Zheng, M., Zeng, L. M., Kiang, C. S., Zhang, Y. H., Lau, A. K. H., et al. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.02.032 · Cited by 185
Self-citationLaboratory Evaluation of the Shinyei PPD42NS Low-Cost Particulate Matter Sensor
Austin, E., Novosselov, I., Seto, E., & Yost, M. G. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137789 · Cited by 167
Mukherjee, A. D., Stanton, L., Graham, A., & Roberts, P. (2017) · Sensors · doi:10.3390/s17081805 · Cited by 162
Investigation of PM2.5 mass concentration over India using a regional climate model
Bran, S. H., & Srivastava, R. C. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2017.02.030 · Cited by 89
Contribution of Brown Carbon to Direct Radiative Forcing over the Indo-Gangetic Plain
Moosakutty, S. P., Tripathi, S. N., Pathak, R. K., Hallquist, M., Arola, A., & Bergin, M. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b03368 · Cited by 86
Self-citationVillalobos, A. M., Amonov, M. O., Shafer, M. M., Devi, J. J., Gupta, T., Tripathi, S., Rana, K. S., Mckenzie, M., Bergin, M. H., & Schauer, J. J. (2015) · Atmospheric Pollution Research · doi:10.5094/apr.2015.044 · Cited by 85
Self-citationGhosh, S., Gupta, T., Rastogi, N., Gaur, A., Misra, A., Tripathi, S. N., Paul, D., Tare, V., Prakash, O., Bhattu, D., et al. (2014) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2013.07.0240 · Cited by 67
Self-citationLi, Z., Li, L., Zhang, F., Li, D., Xie, Y., & Xu, H. (2015) · Journal of Geophysical Research Atmospheres · doi:10.1002/2014jd022593 · Cited by 50
Breen, M. S., Long, T. C., Schultz, B. D., Williams, R. W., Richmond‐Bryant, J., Breen, M., Langstaff, J. E., Devlin, R. B., Schneider, A. E., Burke, J. M., et al. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b02765 · Cited by 48
Soneja, S. I., Chen, C., Tielsch, J. M., Katz, J., Zeger, S. L., Checkley, W., Curriero, F. C., & Breysse, P. N. (2014) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph110606400 · Cited by 38
Cited by
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Barkjohn, K. K., Gantt, B., & Clements, A. L. (2021) · Atmospheric Measurement Techniques · doi:10.5194/amt-14-4617-2021 · Cited by 392
Malings, C., Tanzer, R., Hauryliuk, A., Saha, P. K., Robinson, A. L., Presto, A. A., & Subramanian, R. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1623863 · Cited by 343
Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site
Feenstra, B., Papapostolou, V., Hasheminassab, S., Zhang, H., Boghossian, B. D., Cocker, D., & Polidori, A. (2019) · Atmospheric Environment · doi:10.1016/j.atmosenv.2019.116946 · Cited by 265
Low-Cost Outdoor Air Quality Monitoring and Sensor Calibration: A Survey and Critical Analysis
Concas, F., Mineraud, J., Lagerspetz, E., Varjonen, S., Liu, X., Puolamäki, K., Nurmi, P., & Tarkoma, S. (2021) · ACM Transactions on Sensor Networks · doi:10.1145/3446005 · Cited by 265
Metadata
- Authors
- Zheng, T., Bergin, M. H., Johnson, K. K., Tripathi, S. N., Shirodkar, S., Landis, M. S., Sutaria, R., & Carlson, D. E.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2018-08-22
- Volume
- 11
- Issue
- 8
- Pages
- 4823-4846
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2801553349
- Cited by
- 418
- References
- 24
- FWCI
- 21.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.