Advances in embedded systems and low-cost gas sensors are enabling a new wave of low-cost air quality monitoring tools. Our team has been engaged in the development of low-cost, wearable, air quality monitors (M-Pods) using the Arduino platform. These M-Pods house two types of sensors – commercially available metal oxide semiconductor (MOx) sensors used to measure CO, O3, NO2, and total VOCs, and NDIR sensors used to measure CO2. The MOx sensors are low in cost and show high sensitivity near ambient levels; however they display non-linear output signals and have cross-sensitivity effects. Thus, a quantification system was developed to convert the MOx sensor signals into concentrations. We conducted two types of validation studies – first, deployments at a regulatory monitoring station in Denver, Colorado, and second, a user study. In the two deployments (at the regulatory monitoring station), M-Pod concentrations were determined using collocation calibrations and laboratory calibration techniques. M-Pods were placed near regulatory monitors to derive calibration function coefficients using the regulatory monitors as the standard. The form of the calibration function was derived based on laboratory experiments. We discuss various techniques used to estimate measurement uncertainties. The deployments revealed that collocation calibrations provide more accurate concentration estimates than laboratory calibrations. During collocation calibrations, median standard errors ranged between 4.0–6.1 ppb for O3, 6.4–8.4 ppb for NO2, 0.28–0.44 ppm for CO, and 16.8 ppm for CO2. Median signal to noise (S / N) ratios for the M-Pod sensors were higher than the regulatory instruments: for NO2, 3.6 compared to 23.4; for O3, 1.4 compared to 1.6; for CO, 1.1 compared to 10.0; and for CO2, 42.2 compared to 300–500. By contrast, lab calibrations added bias and made it difficult to cover the necessary range of environmental conditions to obtain a good calibration. A separate user study was also conducted to assess uncertainty estimates and sensor variability. In this study, 9 M-Pods were calibrated via collocation multiple times over 4 weeks, and sensor drift was analyzed, with the result being a calibration function that included baseline drift. Three pairs of M-Pods were deployed, while users individually carried the other three. The user study suggested that inter-M-Pod variability between paired units was on the same order as calibration uncertainty; however, it is difficult to make conclusions about the actual personal exposure levels due to the level of user engagement. The user study provided real-world sensor drift data, showing limited CO drift (under −0.05 ppm day−1), and higher for O3 (−2.6 to 2.0 ppb day−1), NO2 (−1.56 to 0.51 ppb day−1), and CO2 (−4.2 to 3.1 ppm day−1). Overall, the user study confirmed the utility of the M-Pod as a low-cost tool to assess personal exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
Metal oxides for solid-state gas sensors: What determines our choice?
Korotcenkov, G. (2007) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2007.01.044 · Cited by 1,670
Metal Oxide Semi-Conductor Gas Sensors in Environmental Monitoring
Fine, G. F., Cavanagh, L. M., Afonja, A., & Binions, R. (2010) · Sensors · doi:10.3390/s100605469 · Cited by 1,477
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
A brief history of electronic noses
Gardner, J. W., & Bartlett, P. N. (1994) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(94)87085-3 · Cited by 1,255
Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104789 · Cited by 1,064 · cited 2×
“Elevated concentrations have also been 20 found to affect decision-making and exam performance (Satish et al., 2012).”
BackgroundMead, M. I., Popoola, O. A. M., Stewart, G. B., Landshoff, P., Calleja, M., Hayes, M., Baldovi, J. J., McLeod, M. W., Hodgson, T. F., Dicks, J., et al. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.11.060 · Cited by 828
Moseley, P. T. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/3/003 · Cited by 726
Chemical gas sensor drift compensation using classifier ensembles
Vergara, A., Vembu, S., Ayhan, T., Ryan, M. A., Homer, M. L., & Huerta, R. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.01.074 · Cited by 724
Kaur, S., Nieuwenhuijsen, M. J., & Colvile, R. N. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.02.002 · Cited by 432
Romain, A. C., & Nicolas, J. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.12.027 · Cited by 334
Zampolli, S., Elmi, I., Ahmed, F., Passini, M., Cardinali, G. C., Nicoletti, S., & Dori, L. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.02.024 · Cited by 239
Vergara, A., Fonollosa, J., Mahiques, J., Trincavelli, M., Rulkov, N., & Huerta, R. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.05.027 · Cited by 188
Tsow, F., Forzani, E., Rai, A., Wang, R., Tsui, R., Mastroianni, S., Knobbe, C., Gandolfi, A. J., & Tao, N. J. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2030747 · Cited by 185
YASUDA, T., Yonemura, S., & Tani, A. (2012) · Sensors · doi:10.3390/s120303641 · Cited by 184
ARIEL: automatic wi-fi based room fingerprinting for indoor localization
Jiang, Y., Pan, X., Li, K., Lv, Q., Dick, R. P., Hannigan, M., & Shang, L. (2012) · Proceedings of the 2012 ACM Conference on Ubiquitous Computing · doi:10.1145/2370216.2370282 · Cited by 172
Self-citationA calibration method for handling the temporal drift of solid state gas-sensors
Haugen, J., Tomić, O., & Kvaal, K. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00784-9 · Cited by 162
Sundgren, H., Winquist, F., Lukkari, I., & Lundström, I. (1991) · Measurement Science and Technology · doi:10.1088/0957-0233/2/5/008 · Cited by 128
Williams, D. E., Henshaw, G. S., Bart, M., Laing, G., Wagner, J., Naisbitt, S. C., & Salmond, J. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/6/065803 · Cited by 103
Algorithmic mitigation of sensor failure: Is sensor replacement really necessary?
Fonollosa, J., Vergara, A., & Huerta, R. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.03.034 · Cited by 72
The need for external validation in machine olfaction: emphasis on health-related applications
Marco, S. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7807-7 · Cited by 67
Martinelli, E., Magna, G., Vito, S. D., Fuccio, R. D., Francia, G. D., Vergara, A., & Natale, C. D. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.11.107 · Cited by 61
Dutton, S. J., Schauer, J. J., Vedal, S., & Hannigan, M. P. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.10.003 · Cited by 48
Self-citationNeff, W. D. (1997) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1997.10464447 · Cited by 40
On the Development of a Sensor Module for Real-Time Pollution Monitoring
Shum, L. V., Rajalakshmi, P., Afonja, A., McPhillips, G., Binions, R., Cheng, L., & Hailes, S. M. V. (2011) · International Conference on Information Science and Applications · doi:10.1109/icisa.2011.5772355 · Cited by 26
Cited by
Monks, P. S., Archibald, A. T., Colette, A., Cooper, O., Coyle, M., Derwent, R., Fowler, D., Granier, C., Law, K. S., Mills, G. E., et al. (2015) · Atmospheric Chemistry and Physics · doi:10.5194/acp-15-8889-2015 · Cited by 1,572
Castell, N., Dauge, F. R., Schneider, P., Vogt, M., Lerner, U., Fishbain, B., Broday, D., & Bartonova, A. (2017) · Environment International · doi:10.1016/j.envint.2016.12.007 · Cited by 1,039
Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., et al. (2018) · Environment International · doi:10.1016/j.envint.2018.04.018 · Cited by 864
Zimmerman, N., Presto, A. A., Kumar, S. P. N., Gu, J., Hauryliuk, A., Robinson, E. S., Robinson, A. L., & Subramanian, R. (2018) · Atmospheric Measurement Techniques · doi:10.5194/amt-11-291-2018 · Cited by 566
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Metadata
- Authors
- Piedrahita, R., Xiang, Y., Masson, N., Ortega, J., Collier, A., Jiang, Y., Li, K., Dick, R. P., Lv, Q., Hannigan, M., & Shang, L.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2014-10-07
- Volume
- 7
- Issue
- 10
- Pages
- 3325-3336
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2135747820
- Cited by
- 283
- References
- 25
- FWCI
- 12.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.