The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Development of Implantable Medical Devices: From an Engineering Perspective
Open accessAbstract
From the first pacemaker implant in 1958, numerous engineering and medical activities for implantable medical device development have faced challenges in materials, battery power, functionality, electrical power consumption, size shrinkage, system delivery, and wireless communication. With explosive advances in scientific and engineering technology, many implantable medical devices such as the pacemaker, cochlear implant, and real-time blood pressure sensors have been developed and improved. This trend of progress in medical devices will continue because of the coming super-aged society, which will result in more consumers for the devices. The inner body is a special space filled with electrical, chemical, mechanical, and marine-salted reactions. Therefore, electrical connectivity and communication, corrosion, robustness, and hermeticity are key factors to be considered during the development stage. The main participants in the development stage are the user, the medical staff, and the engineer or technician. Thus, there are three different viewpoints in the development of implantable devices. In this review paper, considerations in the development of implantable medical devices will be presented from the viewpoint of an engineering mind.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Encapsulation materials which are conventionally electrical insulators need to be both biocompatible and resistant to bio-dissolution (Geddes and Roeder 2003; Joung 2013).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Joung 2013
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
The history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,861
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 918
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Resuscitation of the Heart in Ventricular Standstill by External Electric Stimulation
Zoll, P. M. (1952) · New England Journal of Medicine · doi:10.1056/nejm195211132472005 · Cited by 638
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 423
Energy harvesting by implantable abiotically catalyzed glucose fuel cells
Kerzenmacher, S., Ducrée, J., Zengerle, R., & von Stetten, F. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.03.031 · Cited by 374
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
Corrosion fatigue of biomedical metallic alloys: Mechanisms and mitigation
Antunes, R. A., & de Oliveira, M. C. L. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.012 · Cited by 250
Trends in cardiac pacemaker batteries.
Mallela, V. S., Ilankumaran, V., & Rao, N. S. (2004) · PubMed · Cited by 244
Flagged first, then by citations
Research works printed but not linked: 23
- Jiang, 2010, Implantable neural prostheses 2: techniques and engineering approaches, 28
- Magjarevic, 2010, Zdrav Vestn, 79, 55
- Furman, 2002, Indian Pacing Electrophysiol J, 2, 2
- Axisa, 2009, Conf Proc IEEE Eng Med Biol Soc, 2009, 4864
- Narasimhan, 2010, Conf Proc IEEE Eng Med Biol Soc, 2010, 6425
- Sugii, 2003, Fujitsu Sci Tech J, 39, 9
- Mallela, 2004, Indian Pacing Electrophysiol J, 4, 201
- Kramar, 2012, GRANT J, 1, 77
- Waurzyniak, 2010, Manuf Eng, 144, 1
- Tilton, 2004, Manag Infect Control, 66
- Silindir, 2009, FABAD J Pharm Sci, 34, 43
- Schuettler, 2011, Conf Proc IEEE Eng Med Biol Soc, 2011, 2296
- von Metzen, 2007, Conf Proc IEEE Eng Med Biol Soc, 2007, 6601
- Placko, 2000, Int J Oral Maxillofac Implants, 15, 355
- Bundy, 1994, Crit Rev Biomed Eng, 22, 139
- Bruck, 1991, J Long Term Eff Med Implants, 1, 89
- Chlebowski, 2012, Biomed Mater Eng, 22, 361
- Schuettler, 2010, Conf Proc IEEE Eng Med Biol Soc, 2010, 1585
- Chen, 2011, Adv Biochem Eng Biotechnol, 125, 29
- Kazemi, 2004, Conf Proc IEEE Eng Med Biol Soc, 6, 4093
- Guenther, 2011, Conf Proc IEEE Eng Med Biol Soc, 2011, 6717
- Seo, 1989, Front Med Biol Eng, 1, 319
- Mitcheson, 2010, Conf Proc IEEE Eng Med Biol Soc, 2010, 3432
Cited by
Sorted by citations
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2019) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,013
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M., Salieb–Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 878
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Cao, X., Xiong, Y., Sun, J., Zhu, X., Sun, Q., & Wang, Z. L. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202102983 · Cited by 369
Metadata
- Authors
- Joung, Y.-H.
- Affiliations
- Hanbat National University (KR)
- Corresponding author
- Joung, Yeun-Ho
- ORCID
- Joung, Yeun-Ho
- Venue
- International Neurourology Journal
- Publisher
- Korean Continence Society
- Published
- 2013
- Volume
- 17
- Issue
- 3
- Pages
- 98
- ISSN
- 2093-4777 (ISSN-L)
- 2093-6931
- PMC
- PMC3797898
- OpenAlex
- W2003687987
- Cited by
- 367
- References
- 83
- Citations by year
- 2026: 21 · 2025: 37 · 2024: 47 · 2023: 33 · 2022: 40 · 2021: 49 · 2020: 32 · 2019: 23 · 2018: 30 · 2017: 19 · 2016: 14 · 2015: 7 · 2014: 14 · 2013: 1
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- Locations
- International Neurourology Journal (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Innovative Technology Development Program funded by the Small and Medium Business Administration of Korea (S2105913)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- biomedical implants, cardiac pacemaker, cochlear implants, blood pressure sensor, biomaterials, implantable batteries, electrical power consumption, device miniaturization, wireless communication, corrosion, hermeticity, electrical connectivity, population aging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review