Additive manufacturing of titanium alloys in the biomedical field: processes, properties and applications
Open accessThe DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
The mechanical properties and biocompatibility of titanium alloy medical devices and implants produced by additive manufacturing (AM) technologies – in particular, selective laser melting (SLM), electron beam melting (EBM) and laser metal deposition (LMD) – have been investigated by several researchers demonstrating how these innovative processes are able to fulfil medical requirements for clinical applications. This work reviews the advantages given by these technologies, which include the possibility to create porous complex structures to improve osseointegration and mechanical properties (best match with the modulus of elasticity of local bone), to lower processing costs, to produce custom-made implants according to the data for the patient acquired via computed tomography and to reduce waste.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Metal Additive Manufacturing: A Review
Frazier, W. E. (2014) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-014-0958-z · Cited by 5,984 · cited 1×
“Higher stiffness and strength and lower ductility (E = 118 GPa, UTS = 915 MPa, yield strength [YS] = 830 MPa, ε = 13%) are generally recorded for as-built EBM Ti-6Al4V materials compared with wrought and annealed ones (E = 104 GPa, UTS = 870 MPa, YS = 790 MPa, ε = 18) (88-91).”
BackgroundCellular solids: Structure and properties
Wolcott, M. P. (1990) · Materials Science and Engineering: A · doi:10.1016/0921-5093(90)90295-e · Cited by 5,926
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Additive manufacturing of metals
Herzog, D., Seyda, V., Wycisk, E., & Emmelmann, C. (2016) · Acta Materialia · doi:10.1016/j.actamat.2016.07.019 · Cited by 4,759
Manufacture, characterisation and application of cellular metals and metal foams
Banhart, J. (2001) · Progress in Materials Science · doi:10.1016/s0079-6425(00)00002-5 · Cited by 3,780
Ashby, M., Evans, A., Fleck, N., Gibson, L., Hutchinson, J., Wadley, H., & Delale, F. (2001) · Applied Mechanics Reviews · doi:10.1115/1.1421119 · Cited by 2,694
The metallurgy and processing science of metal additive manufacturing
Sames, W. J., List, F. A., Pannala, S., Dehoff, R. R., & Babu, S. S. (2016) · International Materials Reviews · doi:10.1080/09506608.2015.1116649 · Cited by 2,529
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406 · cited 1×
“Traditionally, the surface of an implant could be modified by sandblasting, plasma spraying and acid etching to obtain the desired roughness (65, 66).”
Background
Cited by
An Overview on 3D Printing Technology: Technological, Materials, and Applications
Shahrubudin, N., Lee, T. C., & Ramlan, R. (2019) · Procedia Manufacturing · doi:10.1016/j.promfg.2019.06.089 · Cited by 2,050
Selective laser melting of Ti6Al4V alloy: Process parameters, defects and post-treatments
Singla, A. K., Banerjee, M., Sharma, A., Singh, J., Bansal, A., Gupta, M. K., Khanna, N., Shahi, A. S., & Goyal, D. K. (2021) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2021.01.009 · Cited by 383
Marchese, G., Lorusso, M., Parizia, S., Bassini, E., Lee, J.-W., Calignano, F., Manfredi, D., Terner, M., Hong, H.-U., Ugues, D., et al. (2018) · Materials Science and Engineering: A · doi:10.1016/j.msea.2018.05.044 · Cited by 290
Self-citationGarot, C., Bettega, G., & Picart, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006967 · Cited by 214
Metadata
- Authors
- Trevisan, F., Calignano, F., Aversa, A., Marchese, G., Lombardi, M., Biamino, S., Ugues, D., & Manfredi, D.
- Venue
- Journal of Applied Biomaterials & Functional Materials
- Publisher
- SAGE Publications
- Published
- 2017-09-25
- Volume
- 16
- Issue
- 2
- Pages
- 57-67
- ISSN
- 1722-6899 (ISSN-L)
- 2280-8000
- OpenAlex
- W2757064281
- Cited by
- 295
- References
- 78
- FWCI
- 14.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.