The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Additive manufacturing of titanium alloys in the biomedical field: processes, properties and applications
Open accessAbstract
The mechanical properties and biocompatibility of titanium alloy medical devices and implants produced by additive manufacturing (AM) technologies – in particular, selective laser melting (SLM), electron beam melting (EBM) and laser metal deposition (LMD) – have been investigated by several researchers demonstrating how these innovative processes are able to fulfil medical requirements for clinical applications. This work reviews the advantages given by these technologies, which include the possibility to create porous complex structures to improve osseointegration and mechanical properties (best match with the modulus of elasticity of local bone), to lower processing costs, to produce custom-made implants according to the data for the patient acquired via computed tomography and to reduce waste.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Metal Additive Manufacturing: A Review
Frazier, W. E. (2014) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-014-0958-z · Cited by 5,984 · cited 1×
“Higher stiffness and strength and lower ductility (E = 118 GPa, UTS = 915 MPa, yield strength [YS] = 830 MPa, ε = 13%) are generally recorded for as-built EBM Ti-6Al4V materials compared with wrought and annealed ones (E = 104 GPa, UTS = 870 MPa, YS = 790 MPa, ε = 18) (88-91).”
BackgroundCellular solids: Structure and properties
Wolcott, M. P. (1990) · Materials Science and Engineering: A · doi:10.1016/0921-5093(90)90295-e · Cited by 5,926
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
Additive manufacturing of metals
Herzog, D., Seyda, V., Wycisk, E., & Emmelmann, C. (2016) · Acta Materialia · doi:10.1016/j.actamat.2016.07.019 · Cited by 4,759
Manufacture, characterisation and application of cellular metals and metal foams
Banhart, J. (2001) · Progress in Materials Science · doi:10.1016/s0079-6425(00)00002-5 · Cited by 3,780
Ashby, M., Evans, A., Fleck, N., Gibson, L., Hutchinson, J., Wadley, H., & Delale, F. (2001) · Applied Mechanics Reviews · doi:10.1115/1.1421119 · Cited by 2,694
The metallurgy and processing science of metal additive manufacturing
Sames, W. J., List, F. A., Pannala, S., Dehoff, R. R., & Babu, S. S. (2016) · International Materials Reviews · doi:10.1080/09506608.2015.1116649 · Cited by 2,529
Osteoblast adhesion on biomaterials
Anselme, K. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00242-2 · Cited by 2,500
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Vrancken, B., Thijs, L., Kruth, J.-P., & Van Humbeeck, J. (2012) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2012.07.022 · Cited by 1,896
Additive manufacturing and its societal impact: a literature review
Huang, S. H., Liu, P., Mokasdar, A., & Hou, L. (2013) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-012-4558-5 · Cited by 1,862
Carroll, B. E., Palmer, T. A., & Beese, A. M. (2015) · Acta Materialia · doi:10.1016/j.actamat.2014.12.054 · Cited by 1,507
Vilaro, T., Colin, C., & Bartout, J. D. (2011) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-011-0731-y · Cited by 1,283
Shamsaei, N., Yadollahi, A., Bian, L., & Thompson, S. M. (2015) · Additive Manufacturing · doi:10.1016/j.addma.2015.07.002 · Cited by 1,108
Light Alloys: From Traditional Alloys to Nanocrystals
Polmear, I. J. (2006) · Cited by 1,049
Murr, L. E., Quinones, S. A., Gaytan, S. M., Lopez, M. I., Rodela, A., Martinez, E. Y., Hernandez, D. H., Martinez, E., Medina, F., & Wicker, R. B. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.05.004 · Cited by 997
Rafi, H. K., Karthik, N. V., Gong, H., Starr, T. L., & Stucker, B. E. (2013) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-013-0658-0 · Cited by 987
Sing, S. L., An, J., Yeong, W. Y., & Wiria, F. E. (2016) · Journal of Orthopaedic Research · doi:10.1002/jor.23075 · Cited by 942
Al-Bermani, S. S., Blackmore, M., Zhang, W., & Todd, I. (2010) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-010-0397-x · Cited by 860
Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)
Parthasarathy, J., Starly, B., Raman, S., & Christensen, A. (2010) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2009.10.006 · Cited by 816
Van Bael, S., Chai, Y. C., Truscello, S., Moesen, M., Kerckhofs, G., Van Oosterwyck, H., Kruth, J.-P., & Schrooten, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.04.001 · Cited by 766
Antonysamy, A. A., Meyer, J., & Prangnell, P. B. (2013) · Materials Characterization · doi:10.1016/j.matchar.2013.07.012 · Cited by 747
Improvement of fatigue resistance and ductility of TiAl6V4 processed by selective laser melting
Kasperovich, G., & Hausmann, J. (2015) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2015.01.025 · Cited by 735
Additive layered manufacturing: sectors of industrial application shown through case studies
Petrovic, V., Vicente Haro Gonzalez, J., Jordá Ferrando, O., Delgado Gordillo, J., Ramón Blasco Puchades, J., & Portolés Griñan, L. (2011) · International Journal of Production Research · doi:10.1080/00207540903479786 · Cited by 676
Zhao, X., Li, S., Zhang, M., Liu, Y., Sercombe, T. B., Wang, S., Hao, Y., Yang, R., & Murr, L. E. (2016) · Materials & Design · doi:10.1016/j.matdes.2015.12.135 · Cited by 673
Smith, M., Guan, Z., & Cantwell, W. J. (2013) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2012.12.004 · Cited by 545
Metal ion release from metal implants
Hanawa, T. (2004) · Materials Science and Engineering: C · doi:10.1016/j.msec.2004.08.018 · Cited by 528
Ductility of a Ti‐6Al‐4V alloy produced by selective laser melting of prealloyed powders
Facchini, L., Magalini, E., Robotti, P., Molinari, A., Höges, S., & Wissenbach, K. (2010) · Rapid Prototyping Journal · doi:10.1108/13552541011083371 · Cited by 512
Metallic Scaffolds for Bone Regeneration
Alvarez, K., & Nakajima, H. (2009) · Materials · doi:10.3390/ma2030790 · Cited by 505
Additive manufacturing technologies: state of the art and trends
Gardan, J. (2016) · International Journal of Production Research · doi:10.1080/00207543.2015.1115909 · Cited by 489
Uriondo, A., Esperon-Miguez, M., & Perinpanayagam, S. (2015) · Proceedings of the Institution of Mechanical Engineers, Part G: Journal of Aerospace Engineering · doi:10.1177/0954410014568797 · Cited by 489
Rosales-Leal, J. I., Rodríguez-Valverde, M. A., Mazzaglia, G., Ramón-Torregrosa, P. J., Díaz-Rodríguez, L., García-Martínez, O., Vallecillo-Capilla, M., Ruiz, C., & Cabrerizo-Vílchez, M. A. (2010) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2009.12.017 · Cited by 471
Processing and biocompatibility evaluation of laser processed porous titanium
Xue, W., Krishna, B. V., Bandyopadhyay, A., & Bose, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.05.009 · Cited by 471
Microstructures of laser-deposited Ti–6Al–4V
Wu, X., Liang, J., Mei, J., Mitchell, C., Goodwin, P. S., & Voice, W. (2004) · Materials & Design · doi:10.1016/j.matdes.2003.09.009 · Cited by 436
Stainless steel in bone surgery
Disegi, J. A., & Eschbach, L. (2000) · Injury · doi:10.1016/s0020-1383(00)80015-7 · Cited by 414
Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturing
Campoli, G., Borleffs, M. S., Amin Yavari, S., Wauthle, R., Weinans, H., & Zadpoor, A. A. (2013) · Materials & Design · doi:10.1016/j.matdes.2013.01.071 · Cited by 404
Pattanayak, D. K., Fukuda, A., Matsushita, T., Takemoto, M., Fujibayashi, S., Sasaki, K., Nishida, N., Nakamura, T., & Kokubo, T. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.09.034 · Cited by 384
Fatigue behavior and failure mechanisms of direct laser deposited Ti–6Al–4V
Sterling, A. J., Torries, B., Shamsaei, N., Thompson, S. M., & Seely, D. W. (2015) · Materials Science and Engineering A · doi:10.1016/j.msea.2015.12.026 · Cited by 372
Cranial reconstruction: 3D biomodel and custom-built implant created using additive manufacturing
Jardini, A. L., Larosa, M. A., Filho, R. M., Zavaglia, C. A. D. C., Bernardes, L. F., Lambert, C. S., Calderoni, D. R., & Kharmandayan, P. (2014) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2014.07.006 · Cited by 350
Hrabe, N. W., & Quinn, T. P. (2013) · Materials Science and Engineering A · doi:10.1016/j.msea.2013.02.065 · Cited by 349
Laser Additive Manufacturing of High-Performance Materials
Gu, D. (2015) · Springer eBooks · doi:10.1007/978-3-662-46089-4 · Cited by 349
Cheng, X. Y., Li, S. J., Murr, L. E., Zhang, Z. B., Hao, Y. L., Yang, R., Medina, F., & Wicker, R. B. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.10.005 · Cited by 329
Osteoblastic cell behaviour on different titanium implant surfaces
Le Guehennec, L., Lopez-Heredia, M.-A., Enkel, B., Weiss, P., Amouriq, Y., & Layrolle, P. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.12.002 · Cited by 293
Facchini, L., Magalini, E., Robotti, P., & Molinari, A. (2009) · Rapid Prototyping Journal · doi:10.1108/13552540910960262 · Cited by 290
Fabrication of Ti-6Al-4V Scaffolds by Direct Metal Deposition
Dinda, G. P., Song, L., & Mazumder, J. (2008) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-008-9634-y · Cited by 288
Wadley, H. N. G. (2002) · Advanced Engineering Materials · doi:10.1002/1527-2648(20021014)4:10<726::aid-adem726>3.0.co;2-y · Cited by 283
An overview of recent advances in designing orthopedic and craniofacial implants
Mantripragada, V. P., Lecka‐Czernik, B., Ebraheim, N. A., & Jayasuriya, A. C. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34605 · Cited by 273
Properties of Ti–6Al–4V non-stochastic lattice structures fabricated via electron beam melting
Cansizoglu, O., Harrysson, O. L. A., Cormier, D., West, H., & Mahale, T. (2008) · Materials Science and Engineering A · doi:10.1016/j.msea.2008.04.002 · Cited by 267
Zhao, S., Li, S. J., Hou, W. T., Hao, Y. L., Yang, R., & Misra, R. D. K. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.01.034 · Cited by 262
Metals for bone implants. Part 1. Powder metallurgy and implant rendering
Andani, M. T., Shayesteh Moghaddam, N., Haberland, C., Dean, D., Miller, M. J., & Elahinia, M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.06.025 · Cited by 258
Murr, L. E., Gaytan, S. M., Medina, F., Martinez, E., Martinez, J. L., Hernandez, D. H., Machado, B. I., Ramirez, D. A., & Wicker, R. B. (2010) · Materials Science and Engineering: A · doi:10.1016/j.msea.2009.11.015 · Cited by 258
Laser Metal Deposition as Repair Technology for Stainless Steel and Titanium Alloys
Graf, B., Gumenyuk, A., & Rethmeier, M. (2012) · Physics Procedia · doi:10.1016/j.phpro.2012.10.051 · Cited by 218
Gorny, B., Niendorf, T., Lackmann, J., Thoene, M., Troester, T., & Maier, H. J. (2011) · Materials Science and Engineering: A · doi:10.1016/j.msea.2011.07.026 · Cited by 213
Lin, C., Wirtz, T., LaMarca, F., & Hollister, S. J. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31231 · Cited by 198
Medical design: Direct metal laser sintering of Ti–6Al–4V
Bertol, L. S., Júnior, W. K., Silva, F. P. D., & Aumund-Kopp, C. (2010) · Materials & Design · doi:10.1016/j.matdes.2010.02.050 · Cited by 193
Evaluation of titanium alloy fabricated using electron beam melting system for dental applications
Koike, M., Martinez, K., Guo, L., Chahine, G., Kovacevic, R., & Okabe, T. (2011) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2011.03.013 · Cited by 182
Titanium alloy mini-implants for orthodontic anchorage: Immediate loading and metal ion release
Morais, L. S., Serra, G. G., Muller, C. A., Andrade, L. R., Palermo, E. F. A., Elias, C. N., & Meyers, M. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.10.010 · Cited by 182
Wu, S., Li, Y., Zhang, Y., Li, X., Yuan, C., Hao, Y., Zhang, Z., & Guo, Z. (2013) · Artificial Organs · doi:10.1111/aor.12153 · Cited by 181
In vivo performance of selective electron beam‐melted Ti‐6Al‐4V structures
Ponader, S., von Wilmowsky, C., Widenmayer, M., Lutz, R., Heinl, P., Körner, C., Singer, R. F., Nkenke, E., Neukam, F. W., & Schlegel, K. A. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32337 · Cited by 179
Bordjih, K., Jouzeau, J.-Y., Mainard, D., Payan, E., Delagoutte, J.-P., & Netter, P. (1996) · Biomaterials · doi:10.1016/0142-9612(96)82723-2 · Cited by 172
Mechanical Properties and Microstructural Features of Direct Laser-Deposited Ti-6Al-4V
Bian, L., Thompson, S. M., & Shamsaei, N. (2015) · JOM · doi:10.1007/s11837-015-1308-9 · Cited by 170
Titanium foams for biomedical applications: a review
Singh, R., Lee, P. D., Dashwood, R. J., & Lindley, T. C. (2010) · Materials Technology · doi:10.1179/175355510x12744412709403 · Cited by 166
Biomedical Engineering - From Theory to Applications
Fazel-Rezai, R. (2011) · InTech eBooks · doi:10.5772/2629 · Cited by 165
Tang, H., Yang, G. Y., Jia, W., He, W., Lu, S., & Qian, M. (2015) · Materials Science and Engineering A · doi:10.1016/j.msea.2015.03.079 · Cited by 164
Additive Manufacturing for product improvement at Red Bull Technology
Cooper, D. E., Stanford, M., Kibble, K. A., & Gibbons, G. J. (2012) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2012.05.017 · Cited by 156
Customised titanium implant fabricated in additive manufacturing for craniomaxillofacial surgery
Jardini, A. L., Larosa, M. A., Zavaglia, C. A. D. C., Bernardes, L. F., Lambert, C. S., Kharmandayan, P., Calderoni, D. R., & Filho, R. M. (2014) · Virtual and Physical Prototyping · doi:10.1080/17452759.2014.900857 · Cited by 131
Thomsen, P., Malmström, J., Emanuelsson, L., René, M., & Snis, A. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31250 · Cited by 131
Composite biomaterial scaffolds for cardiac tissue engineering
Shapira, A., Feiner, R., & Dvir, T. (2016) · International Materials Reviews · doi:10.1179/1743280415y.0000000012 · Cited by 114
Selective Laser Melting of Ti-45Nb Alloy
Schwab, H., Prashanth, K. G., Löber, L., Kühn, U., & Eckert, J. (2015) · Metals · doi:10.3390/met5020686 · Cited by 113
Spatially dependent properties in a laser additive manufactured Ti–6Al–4V component
Palanivel, S., Dutt, A. K., Faierson, E. J., & Mishra, R. S. (2015) · Materials Science and Engineering A · doi:10.1016/j.msea.2015.12.021 · Cited by 102
Zhuravleva, K., Bönisch, M., Prashanth, K. G., Hempel, U., Helth, A., Gemming, T., Calin, M., Scudino, S., Schultz, L., Eckert, J., et al. (2013) · Materials · doi:10.3390/ma6125700 · Cited by 100
A review of laser fabrication of metallic engineering components and of materials
Wu, X. (2007) · Materials Science and Technology · doi:10.1179/174328407x179593 · Cited by 95
Texture Evolution During Laser Direct Metal Deposition of Ti-6Al-4V
Sridharan, N., Chaudhary, A., Nandwana, P., & Babu, S. S. (2016) · JOM · doi:10.1007/s11837-015-1797-6 · Cited by 85
Biemond, J., Hannink, G., Verdonschot, N. J. J., & Buma, P. (2012) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-012-4836-7 · Cited by 83
Manufacture of Co-Cr dental crowns and bridges by selective laser Melting technology
Averyanova, M., Bertrand, P., & Verquin, B. (2011) · Virtual and Physical Prototyping · doi:10.1080/17452759.2011.619083 · Cited by 61
Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardness
Ayyıldız, S., Soylu, E. H., İde, S., Kılıç, S., Sipahi, C., Pişkin, B., & Gökçe, H. S. (2013) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2013.5.4.471 · Cited by 55
Ikeo, N., Ishimoto, T., & Nakano, T. (2015) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2015.03.141 · Cited by 43
Cited by
An Overview on 3D Printing Technology: Technological, Materials, and Applications
Shahrubudin, N., Lee, T. C., & Ramlan, R. (2019) · Procedia Manufacturing · doi:10.1016/j.promfg.2019.06.089 · Cited by 2,050
Selective laser melting of Ti6Al4V alloy: Process parameters, defects and post-treatments
Singla, A. K., Banerjee, M., Sharma, A., Singh, J., Bansal, A., Gupta, M. K., Khanna, N., Shahi, A. S., & Goyal, D. K. (2021) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2021.01.009 · Cited by 383
Marchese, G., Lorusso, M., Parizia, S., Bassini, E., Lee, J.-W., Calignano, F., Manfredi, D., Terner, M., Hong, H.-U., Ugues, D., et al. (2018) · Materials Science and Engineering: A · doi:10.1016/j.msea.2018.05.044 · Cited by 290
Self-citation
Metadata
- Authors
- Trevisan, F., Calignano, F., Aversa, A., Marchese, G., Lombardi, M., Biamino, S., Ugues, D., & Manfredi, D.
- Venue
- Journal of Applied Biomaterials & Functional Materials
- Publisher
- SAGE Publications
- Published
- 2017-09-25
- Volume
- 16
- Issue
- 2
- Pages
- 57-67
- ISSN
- 1722-6899 (ISSN-L)
- 2280-8000
- OpenAlex
- W2757064281
- Cited by
- 295
- References
- 78
- FWCI
- 14.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.