Insertion of Peripheral Intravenous Cannulae in the Emergency Department: Factors Associated with First-time Insertion Success
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Background: We sought to identify the reasons for peripheral intravenous cannulae insertion in the emergency department (ED), and the first-time insertion success rate, along with patient and clinician factors influencing this phenomenon. Methods: A prospective cohort study of patients requiring peripheral cannulae insertion in a tertiary ED. Clinical and clinician data were obtained. Results: A total 734 peripheral intravenous cannula (PIVC) insertions were included in the study where 460 insertions were analysed. The first-time insertion success incidence was 86%. The antecubital fossa (ACF) site accounted for over 50% of insertions. Multivariate logistic regression modelling to predict first-time insertion success for patient factors found: age <40 versus 80+ years, emaciated versus normal patient size, having a visible or palpable vein/s, and ACF versus forearm insertion site to be statistically significant. Statistically significant clinician factors predicting success were: higher number of prior cannulation procedures performed, and increased clinician perception of the likelihood of a successful insertion. When patient and clinician factors were combined in a logistic regression model, emaciated versus normal, visible vein/s, ACF versus forearm site, higher number of prior PIVC procedures performed and increased clinician perceived likelihood of success were statistically associated with first-time insertion success. Conclusions: Peripheral intravenous cannulation insertion success could be improved if performed by clinicians with greater procedural experience and increased perception of the likelihood of success. Some patient factors predict cannulation success: ‘normal’ body weight, visible vein/s and cubital fossa placement; venepuncture may be a cheaper alternative for others if intravenous therapy is not imperative.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“All selected studies were published after 2012 and conducted in different European countries, 37À40 Australia 41 and the United States.42,43”
From Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis (2020) · cites this paper as [41]
In the citing paper
“The study by Carr et al 41 showed a strong association between the previous number of insertions performed by a clinician and the rate of success of the first attempt of cannulation.”
From Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis (2020) · cites this paper as [41]
In the citing paper
“The four studies in which the visibility and palpability conditions of the vessel were evaluated, 38À41 found statistical significance with up to 5.5 OR (IC 1,37À18.64)for not palpable veins observed in the study by Carr et al. 41”
From Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis (2020) · cites this paper as [41]
In the citing paper
“All selected studies were published after 2012 and conducted in different European countries, 37À40 Australia 41 and the United States.42,43”
From Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis (2020) · cites this paper as [41]
Citations
Cites
A simulation study of the number of events per variable in logistic regression analysis
Peduzzi, P., Concato, J., Kemper, E., Holford, T. R., & Feinstein, A. R. (1996) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(96)00236-3 · Cited by 9,655 · cited 1×
“Peduzzi et al provide a “rule of thumb” recommendation of ten events per variable analysed (42) and there others who recommend that the number required could be reduced (43).”
BackgroundRelaxing the Rule of Ten Events per Variable in Logistic and Cox Regression
Vittinghoff, E., & McCulloch, C. E. (2007) · American Journal of Epidemiology · doi:10.1093/aje/kwk052 · Cited by 4,359 · cited 1×
“Peduzzi et al provide a “rule of thumb” recommendation of ten events per variable analysed (42) and there others who recommend that the number required could be reduced (43).”
BackgroundThe validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339
Wallis, M. C., McGrail, M., Webster, J., Marsh, N., Gowardman, J., Playford, E. G., & Rickard, C. M. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/674398 · Cited by 353
Self-citationJacobson, A. F., & Winslow, E. H. (2005) · Heart & Lung · doi:10.1016/j.hrtlng.2005.04.002 · Cited by 279
Yen, K., Riegert, A., & Gorelick, M. H. (2008) · Pediatric Emergency Care · doi:10.1097/pec.0b013e3181666f32 · Cited by 221
Sebbane, M., Claret, P.-G., Lefebvre, S., Mercier, G., Rubenovitch, J., Jreige, R., Eledjam, J.-J., & de La Coussaye, J.-E. (2013) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2012.07.051 · Cited by 179
Prospective evaluation of peripheral venous access difficulty in emergency care
Lapostolle, F., Catineau, J., Garrigue, B., Monmarteau, V., Houssaye, T., Vecci, I., Tréoux, V., Hospital, B., Crocheton, N., & Adnet, F. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0634-y · Cited by 159
Heyer, N. J., Derzon, J. H., Winges, L. D., Shaw, C. S., Mass, D., Snyder, S. R., Epner, P. L., Nichols, J. H., Gayken, J., Ernst, D. J., et al. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.08.002 · Cited by 141
Riker, M. W., Kennedy, C. J., Winfrey, B. S., Yen, K., & Dowd, M. D. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01205.x · Cited by 128
Tuffaha, H., Rickard, C. M., Webster, J., Marsh, N. M., Gordon, L. G., Wallis, M. C., & Scuffham, P. (2014) · Applied Health Economics and Health Policy · doi:10.1007/s40258-013-0077-2 · Cited by 126
Self-citationIV access difficulty: incidence and delays in an urban emergency department
Witting, M. D. (2012) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2011.07.030 · Cited by 120
Ricard, J.-D., Salomon, L., Boyer, A., Thiery, G., Meybeck, A., Roy, C., Pasquet, B., Le Mière, E., & Dreyfuss, D. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a42c5 · Cited by 104 · cited 1×
“Furthermore, an intervention study tested its efficacy as first-line VAD choice in the critical-care setting (15).”
BackgroundLimm, E. I., Fang, X., Dendle, C., Stuart, R. L., & Egerton‐Warburton, D. (2013) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2013.02.022 · Cited by 96
Bausone-Gazda, D., Lefaiver, C. A., & Walters, S.-A. (2010) · Journal of Infusion Nursing · doi:10.1097/nan.0b013e3181f85be2 · Cited by 82
Cuper, N. J., de Graaff, J. C., van Dijk, A. T. H., Verdaasdonk, R. M., van der Werff, D. B. M., & Kalkman, C. J. (2011) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2011.03685.x · Cited by 81
de Graaff, J. C., Cuper, N. J., Mungra, R. A. A., Vlaardingerbroek, K., Numan, S. C., & Kalkman, C. J. (2013) · Anaesthesia · doi:10.1111/anae.12294 · Cited by 81
Aulagnier, J., Hoc, C., Mathieu, E., Dreyfus, J. F., Fischler, M., & Guen, M. L. (2014) · Academic Emergency Medicine · doi:10.1111/acem.12437 · Cited by 76
Is peripheral line placement more difficult in obese than in lean patients?
Juvin, P., Blarel, A., Bruno, F., & Desmonts, J.-M. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000050570.85195.29 · Cited by 73
A Pilot Study of Ultrasound Analysis before Pediatric Peripheral Vein Cannulation Attempt
Schnadower, D., Lin, S., Perera, P., Smerling, A., & Dayan, P. S. (2007) · Academic Emergency Medicine · doi:10.1197/j.aem.2006.12.016 · Cited by 54
Jacobson, A. F. (1999) · Heart & lung : the journal of critical care · doi:10.1053/hl.1999.v28.a95256 · Cited by 51
Predisposing factors for peripheral intravenous puncture failure in children
de Negri, D. C., Avelar, A. F. M., Andreoni, S., & Pedreira, M. D. L. G. (2012) · Revista Latino-Americana de Enfermagem · doi:10.1590/s0104-11692012000600009 · Cited by 43
Training of Undergraduate Clinicians in Vascular Access: An Integrative Review
Alexandrou, E., Ramjan, L. M., Murphy, J. K., Hunt, L., Betihavas, V., & Frost, S. A. (2012) · Journal of the Association for Vascular Access · doi:10.1016/j.java.2012.07.001 · Cited by 43
A pilot intravenous cannulation team: an Irish perspective
Carr, P. J., Glynn, R. W., Dineen, B., & Kropmans, T. J. (2010) · British Journal of Nursing · doi:10.12968/bjon.2010.19.sup3.48214 · Cited by 40
Self-citationInappropriate intravascular device use: a prospective study
Tiwari, M. M., Hermsen, E. D., Charlton, M. E., Anderson, J. R., & Rupp, M. E. (2011) · Journal of Hospital Infection · doi:10.1016/j.jhin.2011.03.004 · Cited by 32
Introduction of a 4‐hour rule in Western Australian Emergency Departments
Mountain, D. (2010) · Emergency Medicine Australasia · doi:10.1111/j.1742-6723.2010.01327.x · Cited by 30
Zengin, N., & Enç, N. (2007) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2006.01858.x · Cited by 28
Bensghir, M., Chkoura, K., MOUNIR, K., Drissi, M., Elwali, A., Ahtil, R., Meziane, M., Alaoui, H., Elmoqadem, A., Lahlou, J., et al. (2012) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2012.04.002 · Cited by 26
de la Torre-Montero, J.-C., Montealegre-Sanz, M., Faraldo-Cabana, A., Oliva-Pellicer, B., García-Real, I., Fenwick, M., Cáceres, E. M., Rivas-Eguía, B., Vila-Borrajo, C., Valles-Andrés, J., et al. (2014) · The Journal of Vascular Access · doi:10.5301/jva.5000173 · Cited by 22
When is peripheral intravenous catheter insertion indicated in the emergency department?
Kelly, A., & Egerton‐Warburton, D. (2014) · Emergency Medicine Australasia · doi:10.1111/1742-6723.12282 · Cited by 16
Goddard, L., Clayton, S., Peto, T., & Bowler, I. C. J. W. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.08.003 · Cited by 16
Venflons: why can't we resist putting them in?
Thomas, A., Hayes, P. W., Lockie, T., & Harrington, D. H. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2005.10.015 · Cited by 14
Tuffaha, H., Rickard, C. M., Inwood, S., Gordon, L. G., & Scuffham, P. (2014) · Journal of Hospital Infection · doi:10.1016/j.jhin.2014.04.004 · Cited by 13
Self-citationWhat are we waiting for? -editorial-
Robinson, A., Abbey, B., & Abbey, J. (2007) · Australian journal of advanced nursing · Cited by 12
Kelly, A., & Klim, S. (2013) · Emergency Medicine Australasia · doi:10.1111/1742-6723.12121 · Cited by 11
Zhang, M., Lee, M., & Knott, S. (2014) · Emergency Medicine Australasia · doi:10.1111/1742-6723.12277 · Cited by 6
Nurse cannulation: introducing an advanced clinical skill
Hoctor, B. (2009) · Nursing Management · doi:10.7748/nm2009.10.16.6.28.c7285 · Cited by 3
Kelly, A., & Pannifex, J. (2013) · Emergency Medicine Australasia · doi:10.1111/1742-6723.12115 · Cited by 1
Research works printed but not linked: 6
- KerK., TansleyG., BeecherD. Comparison of routes for achieving parenteral access with a focus on the management of patients with Ebola virus disease. Cochrane Database Syst Rev. 2015 Feb 26;2: CD011386.
- FreyA.M. Success rates for peripheral i.v. insertion in a children's hospital. Financial implications. J Intraven Nurs. 1998; 21 (3): 160–5.
- FieldsM.J., PielaN.E., AuA.K., KuB.S. Risk factors associated with difficult venous access in adult ED patients. See comment in PubMed Commons below Am J Emerg Med. 2014; 32 (10): 1179–82.
- WebsterJ., MorrisH-L, RobinsonK., SandersonU. Development and validation of a Vein Assessment Tool (VAT). Aust J Adv Nurs. 2007; 24 (4): 5–7.
- 10.3233/BME-120735 · DOI · Paper page
- FlodgrenG., LoC., MayhewA., OmarO., PereiraC.R., ShepperdS. Interventions to improve professional adherence to guidelines for prevention of device-related infections. Cochrane Database Syst Rev. 2013 Mar28; 3: CD006559.
Cited by
Cooke, M., Ullman, A. J., Ray-Barruel, G., Wallis, M., Corley, A., & Rickard, C. M. (2018) · PLOS ONE · doi:10.1371/journal.pone.0193436 · Cited by 233
Self-citationvan Loon, F. H. J., Buise, M. P., Claassen, J. J. F., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.04.047 · Cited by 195
van Loon, F. H. J., van Hooff, L. W. E., de Boer, H. D., Koopman, S. S. H. A., Buise, M. P., Korsten, H. H. M., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020144 · Cited by 157
“This is in line with the findings in this study [30,35].”
ResultCarr, P. J., Rippey, J. C. R., Cooke, M. L., Trevenen, M. L., Higgins, N. S., Foale, A. S., & Rickard, C. M. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-022278 · Cited by 89
Self-citationPaterson, R. S., Schults, J. A., Slaughter, E., Cooke, M., Ullman, A., Kleidon, T. M., Keijzers, G., Marsh, N., & Rickard, C. M. (2022) · Emergency Medicine Australasia · doi:10.1111/1742-6723.14069 · Cited by 70
“PIVCs are routinely inserted by novice to expert inserters(46) without a clear model of care, resulting in inconsistent delivery of best care to patients at greatest risk of insertion failure.(7) This is combined with an alarming number of idle or “just in case” PIVCs, raising the question: Are we causing more harm th…”
BackgroundSelf-citation
Metadata
- Authors
- Carr, P. J., Rippey, J. C. R., Budgeon, C. A., Cooke, M. L., Higgins, N., & Rickard, C. M.
- Affiliations
- Griffith University (AU)
- The University of Western Australia (AU)
- Corresponding author
- Carr, Peter J.
- Venue
- The Journal of Vascular Access
- Publisher
- SAGE Publications
- Published
- 2015-04-12
- Volume
- 17
- Issue
- 2
- Pages
- 182-190
- ISSN
- 1129-7298 (ISSN-L)
- 1724-6032
- OpenAlex
- W2231619733
- Semantic Scholar
- 69e313ec7c604bc9060ef259c7eaf573e012d390
- Cited by
- 122
- References
- 38
- Citations by year
- 2026: 8 · 2025: 7 · 2024: 16 · 2023: 21 · 2022: 9 · 2021: 14 · 2020: 11 · 2019: 17 · 2018: 13 · 2017: 4 · 2016: 2
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The Journal of Vascular Access (publishedVersion)
- PubMed (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- Griffith Research Online (submittedVersion)
- Faculty of Health; Institute of Health and Biomedical Innovation
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Keywords
- peripheral venous cannulation, emergency department, antecubital fossa, insertion site, patient factors, clinician factors, clinician experience, venipuncture, emaciation, body weight
- MeSH terms
- Adult, Aged, Aged, 80 and over, Catheterization, Peripheral, Catheters, Indwelling, Emergency Service, Hospital, Equipment Design, Female, Humans, Male, Middle Aged, Prospective Studies, Risk Factors, Multivariate Analysis, Logistic Models, Odds Ratio, Treatment Failure, Central Venous Catheters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.