Insertion of Peripheral Intravenous Cannulae in the Emergency Department: Factors Associated with First-time Insertion Success
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Background: We sought to identify the reasons for peripheral intravenous cannulae insertion in the emergency department (ED), and the first-time insertion success rate, along with patient and clinician factors influencing this phenomenon. Methods: A prospective cohort study of patients requiring peripheral cannulae insertion in a tertiary ED. Clinical and clinician data were obtained. Results: A total 734 peripheral intravenous cannula (PIVC) insertions were included in the study where 460 insertions were analysed. The first-time insertion success incidence was 86%. The antecubital fossa (ACF) site accounted for over 50% of insertions. Multivariate logistic regression modelling to predict first-time insertion success for patient factors found: age <40 versus 80+ years, emaciated versus normal patient size, having a visible or palpable vein/s, and ACF versus forearm insertion site to be statistically significant. Statistically significant clinician factors predicting success were: higher number of prior cannulation procedures performed, and increased clinician perception of the likelihood of a successful insertion. When patient and clinician factors were combined in a logistic regression model, emaciated versus normal, visible vein/s, ACF versus forearm site, higher number of prior PIVC procedures performed and increased clinician perceived likelihood of success were statistically associated with first-time insertion success. Conclusions: Peripheral intravenous cannulation insertion success could be improved if performed by clinicians with greater procedural experience and increased perception of the likelihood of success. Some patient factors predict cannulation success: ‘normal’ body weight, visible vein/s and cubital fossa placement; venepuncture may be a cheaper alternative for others if intravenous therapy is not imperative.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“All selected studies were published after 2012 and conducted in different European countries, 37À40 Australia 41 and the United States.42,43”
From Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis (2020) · cites this paper as [41]
In the citing paper
“The study by Carr et al 41 showed a strong association between the previous number of insertions performed by a clinician and the rate of success of the first attempt of cannulation.”
From Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis (2020) · cites this paper as [41]
In the citing paper
“The four studies in which the visibility and palpability conditions of the vessel were evaluated, 38À41 found statistical significance with up to 5.5 OR (IC 1,37À18.64)for not palpable veins observed in the study by Carr et al. 41”
From Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis (2020) · cites this paper as [41]
In the citing paper
“All selected studies were published after 2012 and conducted in different European countries, 37À40 Australia 41 and the United States.42,43”
From Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis (2020) · cites this paper as [41]
Citations
Cites
A simulation study of the number of events per variable in logistic regression analysis
Peduzzi, P., Concato, J., Kemper, E., Holford, T. R., & Feinstein, A. R. (1996) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(96)00236-3 · Cited by 9,655 · cited 1×
“Peduzzi et al provide a “rule of thumb” recommendation of ten events per variable analysed (42) and there others who recommend that the number required could be reduced (43).”
BackgroundRelaxing the Rule of Ten Events per Variable in Logistic and Cox Regression
Vittinghoff, E., & McCulloch, C. E. (2007) · American Journal of Epidemiology · doi:10.1093/aje/kwk052 · Cited by 4,359 · cited 1×
“Peduzzi et al provide a “rule of thumb” recommendation of ten events per variable analysed (42) and there others who recommend that the number required could be reduced (43).”
BackgroundThe validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339
Wallis, M. C., McGrail, M., Webster, J., Marsh, N., Gowardman, J., Playford, E. G., & Rickard, C. M. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/674398 · Cited by 353
Self-citationJacobson, A. F., & Winslow, E. H. (2005) · Heart & Lung · doi:10.1016/j.hrtlng.2005.04.002 · Cited by 279
Yen, K., Riegert, A., & Gorelick, M. H. (2008) · Pediatric Emergency Care · doi:10.1097/pec.0b013e3181666f32 · Cited by 221
Sebbane, M., Claret, P.-G., Lefebvre, S., Mercier, G., Rubenovitch, J., Jreige, R., Eledjam, J.-J., & de La Coussaye, J.-E. (2013) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2012.07.051 · Cited by 179
Prospective evaluation of peripheral venous access difficulty in emergency care
Lapostolle, F., Catineau, J., Garrigue, B., Monmarteau, V., Houssaye, T., Vecci, I., Tréoux, V., Hospital, B., Crocheton, N., & Adnet, F. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0634-y · Cited by 159
Heyer, N. J., Derzon, J. H., Winges, L. D., Shaw, C. S., Mass, D., Snyder, S. R., Epner, P. L., Nichols, J. H., Gayken, J., Ernst, D. J., et al. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.08.002 · Cited by 141
Riker, M. W., Kennedy, C. J., Winfrey, B. S., Yen, K., & Dowd, M. D. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01205.x · Cited by 128
Research works printed but not linked: 6
- KerK., TansleyG., BeecherD. Comparison of routes for achieving parenteral access with a focus on the management of patients with Ebola virus disease. Cochrane Database Syst Rev. 2015 Feb 26;2: CD011386.
- FreyA.M. Success rates for peripheral i.v. insertion in a children's hospital. Financial implications. J Intraven Nurs. 1998; 21 (3): 160–5.
- FieldsM.J., PielaN.E., AuA.K., KuB.S. Risk factors associated with difficult venous access in adult ED patients. See comment in PubMed Commons below Am J Emerg Med. 2014; 32 (10): 1179–82.
- WebsterJ., MorrisH-L, RobinsonK., SandersonU. Development and validation of a Vein Assessment Tool (VAT). Aust J Adv Nurs. 2007; 24 (4): 5–7.
- 10.3233/BME-120735 · DOI · Paper page
- FlodgrenG., LoC., MayhewA., OmarO., PereiraC.R., ShepperdS. Interventions to improve professional adherence to guidelines for prevention of device-related infections. Cochrane Database Syst Rev. 2013 Mar28; 3: CD006559.
Cited by
Cooke, M., Ullman, A. J., Ray-Barruel, G., Wallis, M., Corley, A., & Rickard, C. M. (2018) · PLOS ONE · doi:10.1371/journal.pone.0193436 · Cited by 233
Self-citationvan Loon, F. H. J., Buise, M. P., Claassen, J. J. F., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.04.047 · Cited by 195
van Loon, F. H. J., van Hooff, L. W. E., de Boer, H. D., Koopman, S. S. H. A., Buise, M. P., Korsten, H. H. M., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020144 · Cited by 157
“This is in line with the findings in this study [30,35].”
ResultCarr, P. J., Rippey, J. C. R., Cooke, M. L., Trevenen, M. L., Higgins, N. S., Foale, A. S., & Rickard, C. M. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-022278 · Cited by 89
Self-citationPaterson, R. S., Schults, J. A., Slaughter, E., Cooke, M., Ullman, A., Kleidon, T. M., Keijzers, G., Marsh, N., & Rickard, C. M. (2022) · Emergency Medicine Australasia · doi:10.1111/1742-6723.14069 · Cited by 70
“PIVCs are routinely inserted by novice to expert inserters(46) without a clear model of care, resulting in inconsistent delivery of best care to patients at greatest risk of insertion failure.(7) This is combined with an alarming number of idle or “just in case” PIVCs, raising the question: Are we causing more harm th…”
BackgroundSelf-citationCarr, P. J., Higgins, N. S., Cooke, M. L., Rippey, J., & Rickard, C. M. (2017) · Journal of Hospital Medicine · doi:10.12788/jhm.2836 · Cited by 77
“Characteristics of Included Studies Authors Year Country Study Aim Study Design and Setting Study Population and Sample Size Variables Identifi ed Analytics and Measurement Property Reported FTIS Category of TRA Carr et al.23 2016 Australia To identify factors affecting FTIS.”
Self-citationRodríguez-Calero, M. A., Blanco-Mavillard, I., Morales-Asencio, J. M., Fernández-Fernández, I., Castro-Sánchez, E., & de Pedro-Gómez, J. E. (2020) · Heart & Lung · doi:10.1016/j.hrtlng.2020.01.009 · Cited by 78
Carr, P. J., Rippey, J. C. R., Cooke, M. L., Bharat, C., Murray, K., Higgins, N. S., Foale, A., & Rickard, C. M. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-009196 · Cited by 67
Self-citationRodriguez-Calero, M. A., de Pedro-Gomez, J. E., Molero-Ballester, L. J., Fernandez-Fernandez, I., Matamalas-Massanet, C., Moreno-Mejias, L., Blanco-Mavillard, I., Moya-Suarez, A. B., Personat-Labrador, C., & Morales-Asencio, J. M. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030799 · Cited by 60
“However, we found the patient’s pre-existing health conditions to be less relevant than has been hypothesised in previous research [19,24].”
BackgroundFirst-in-human evaluation of a hand-held automated venipuncture device for rapid venous blood draws
Leipheimer, J. M., Balter, M. L., Chen, A. I., Pantin, E. J., Davidovich, A. E., Labazzo, K. S., & Yarmush, M. L. (2019) · TECHNOLOGY · doi:10.1142/s2339547819500067 · Cited by 68
Rippey, J. C., Carr, P. J., Cooke, M., Higgins, N., & Rickard, C. M. (2016) · Emergency Medicine Australasia · doi:10.1111/1742-6723.12695 · Cited by 50
Self-citationCarr, P. J., Rippey, J. C. R., Cooke, M. L., Higgins, N. S., Trevenen, M., Foale, A., & Rickard, C. M. (2018) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2018.190 · Cited by 48
Self-citationReducing Risks and Improving Vascular Access Outcomes
Morrell, E. (2020) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000377 · Cited by 46
Teaching medical students ultrasound-guided vascular access - which learning method is best?
Lian, A., Rippey, J., & Carr, P. J. (2017) · The Journal of Vascular Access · doi:10.5301/jva.5000730 · Cited by 39
Self-citationFactors affecting the first‐attempt success rate of intravenous cannulation in older people
Yalçınlı, S., Akarca, F. K., Can, Ö., Şener, A., & Akbinar, C. (2019) · Journal of Clinical Nursing · doi:10.1111/jocn.14816 · Cited by 35
Rodriguez-Calero, M. A., Fernandez-Fernandez, I., Molero-Ballester, L. J., Matamalas-Massanet, C., Moreno-Mejias, L., de Pedro-Gomez, J. E., Blanco-Mavillard, I., & Morales-Asencio, J. M. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-020420 · Cited by 35
van Loon, F. H. J., Scholten, H. J., Erp, I. V., Bouwman, R. A., & Daele, A. T. M. D.-V. (2019) · Medical Ultrasonography · doi:10.11152/mu-2120 · Cited by 43
Gerçeker, G. Ö., Ayar, D., Özdemir, E. Z., & Bektaş, M. (2018) · The Journal of Vascular Access · doi:10.1177/1129729818765598 · Cited by 33
Archer‐Jones, A., Sweeny, A. L., Schults, J. A., Rickard, C. M., Johnson, L., Gunter, A., & Watkins, S. (2020) · Australasian Emergency Care · doi:10.1016/j.auec.2019.12.008 · Cited by 34
Self-citationImproving Vascular Access Outcomes and Enhancing Practice
Platt, V., & Osenkarski, S. (2018) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000304 · Cited by 32
Ultrasound guidance versus landmark method for peripheral venous cannulation in adults
Tada, M., Yamada, N., Matsumoto, T., Takeda, C., Furukawa, T. A., & Watanabe, N. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013434.pub2 · Cited by 42
Vessel health and preservation: An integrative review
Fiorini, J., Venturini, G., Conti, F., Funaro, E., Caruso, R., Kangasniemi, M. K., & Sili, A. (2018) · Journal of Clinical Nursing · doi:10.1111/jocn.14707 · Cited by 26
Factors associated with difficult intravenous access in the pediatric emergency department
Lee, S. U., Jung, J. Y., Ham, E. M., Wang, S. W., Park, J. W., Hwang, S., Kim, D. K., & Kwak, Y. H. (2019) · The Journal of Vascular Access · doi:10.1177/1129729819865709 · Cited by 25
Piredda, M., Fiorini, J., Facchinetti, G., Biagioli, V., Marchetti, A., Conti, F., Iacorossi, L., Giannarelli, D., Matarese, M., & De Marinis, M. G. (2019) · Journal of Clinical Nursing · doi:10.1111/jocn.14941 · Cited by 22
Álvarez-Morales, L., Gómez‐Urquiza, J. L., Suleiman‐Martos, N., Membrive‐Jiménez, M. J., González-Díaz, A., García, R., & Liñán-González, A. (2024) · International Emergency Nursing · doi:10.1016/j.ienj.2024.101422 · Cited by 34
Santos‐Costa, P., Sousa, L. B., van Loon, F. H. J., Salgueiro‐Oliveira, A., Parreira, P., Vieira, M. M. D. S., & Graveto, J. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17207552 · Cited by 33
Indarwati, F., Munday, J., & Keogh, S. J. (2021) · Journal of Pediatric Nursing · doi:10.1016/j.pedn.2021.11.007 · Cited by 32
Angles, E., Robin, F., Moal, B., Roy, M., Sesay, M., Ouattara, A., Biais, M., Roullet, S., Saillour-Glénisson, F., & Nouette‐Gaulain, K. (2021) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2021.110435 · Cited by 28
DAT, M., JC, D. L. T.-M., AC, N., Reis, R., MH, B., & SEM, T. (2021) · The Journal of Vascular Access · doi:10.1177/1129729820939335 · Cited by 21
Fernández‐Fernández, I., Parra-García, G., Blanco‐Mavillard, I., Carr, P. J., Santos‐Costa, P., & Rodríguez-Calero, M. Á. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-082631 · Cited by 36
Self-citationHazarika, A., Kajal, K., Reddy, S., Jain, K., & Meena, S. C. (2018) · Anesthesia Essays and Researches · doi:10.4103/aer.aer_151_18 · Cited by 20
Bahl, A., Alsbrooks, K., Zazyczny, K. A., Johnson, S., & Hoerauf, K. (2024) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000535 · Cited by 20
Walker, R., Pires, M. P. D. O., Ray‐Barruel, G., Cooke, M. L., Mihala, G., de Azevedo, S. S., Peterlini, M. A. S., Felipe, M. D. A. A., Álvarez, C. P., Quintanilla, M., et al. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2022.1039232 · Cited by 33
Self-citationDesign and Evaluation of a Handheld Robotic Device for Peripheral Catheterization
Leipheimer, J. M., Balter, M. L., Chen, A., & Yarmush, M. L. (2022) · Journal of Medical Devices · doi:10.1115/1.4053688 · Cited by 19
Kaur, P., Rickard, C. M., Domer, G. S., & Glover, K. R. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.83854 · Cited by 23
Self-citationShokoohi, H., Boniface, K. S., Kulie, P. E., Long, A., & McCarthy, M. L. (2019) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2019.02.003 · Cited by 17
Can, M., & Gerçeker, G. Ö. (2024) · Journal of Pediatric Nursing · doi:10.1016/j.pedn.2024.07.010 · Cited by 15
Casamayor, M., DiDonato, K. P., Hennebert, M., Brazzi, L., & Prosen, G. (2018) · Drugs in Context · doi:10.7573/dic.212524 · Cited by 15
Difficult Intravenous Access and Its Management
Eren, H. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.96613 · Cited by 21
Tran, T. N., Lund, S. B., Nichols, M. D., & Kummer, T. (2019) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2019.03.034 · Cited by 17
Barsky, D., Radomislensky, I., Talmy, T., Gendler, S., Almog, O., & Avital, G. (2023) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000006342 · Cited by 14
van Loon, F. H. J., Willekens, F. J., Buise, M. P., Korsten, H. H. M., Bouwman, R. A., & Daele, A. T. M. D.-V. (2019) · The Journal of Vascular Access · doi:10.1177/1129729819838093 · Cited by 13
Salleras-Duran, L., Fuentes-Pumarola, C., Ballester-Ferrando, D., Congost-Devesa, L., Delclós-Rabassa, J., & Fontova-Almató, A. (2020) · Journal of Emergency Nursing · doi:10.1016/j.jen.2020.06.013 · Cited by 12
Schults, J. A., Marsh, N. M., Ullman, A. J., Kleidon, T. M., Ware, R. S., Byrnes, J., Young, E., Hall, L., Keijzers, G., Cullen, L., et al. (2023) · BMC Health Services Research · doi:10.1186/s12913-023-09499-0 · Cited by 17
Self-citationParenteral versus enteral fluid therapy for children hospitalised with bronchiolitis
Gill, P. J., Anwar, M. R., Kornelsen, E., Parkin, P. C., Mahood, Q., & Mahant, S. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013552.pub2 · Cited by 15
Sandström, L., & Forsberg, A. (2018) · Journal of Vascular Nursing · doi:10.1016/j.jvn.2018.06.002 · Cited by 14
Whalen, M., Maliszewski, B., Sheinfeld, R., Gardner, H., & Baptiste, D. (2018) · Journal of Emergency Nursing · doi:10.1016/j.jen.2018.03.011 · Cited by 10
Psaila, J., Parsons, T. F., Hahn, S. A., & Fichera, L. (2022) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000493 · Cited by 10
Weathers, E., Cazzell, M. A., Thompson, J. A., Grieser, K., & Caraveo, L. (2024) · Nursing Open · doi:10.1002/nop2.70054 · Cited by 9
Larsen, E. N., Byrnes, J., Marsh, N. M., & Rickard, C. M. (2021) · British Journal of Nursing · doi:10.12968/bjon.2021.30.19.s30 · Cited by 13
Self-citationParker, S. I. A., Simmons, S. M., Rutherford, A., Caird, J. K., & Benzies, K. (2021) · Clinical Simulation in Nursing · doi:10.1016/j.ecns.2020.12.010 · Cited by 9
Parenteral versus enteral fluid therapy for children hospitalised with bronchiolitis
Gill, P. J., Parkin, P. C., & Mahant, S. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013552 · Cited by 8
van Loon, F. H. J., Timmerman, R., Brok, G., Korsten, E. H. H. M., Daele, A. T. M. D.-V., & Bouwman, R. A. (2021) · The Journal of Vascular Access · doi:10.1177/1129729821990217 · Cited by 12
Pendleton, B. F., & LaFaye, R. (2021) · Journal for Healthcare Quality · doi:10.1097/jhq.0000000000000331 · Cited by 8
Veinplicity versus heat treatment for vein dilation: A randomised cross-over study
Barton, A. (2019) · The Journal of Vascular Access · doi:10.1177/1129729818818962 · Cited by 8
Alexandrou, E., Mifflin, N., & Carr, P. J. (2019) · Springer eBooks · doi:10.1007/978-3-030-03149-7_4 · Cited by 9
Self-citationPunção venosa periférica difícil: revisão integrativa
Marinho, A. M., Sabino, F. H. O., Monteiro, D. A. T., Filgueira, V. D. S. A., Azevedo, G. N. D., & Toffano, S. E. M. (2019) · Revista Enfermagem UERJ · doi:10.12957/reuerj.2019.42567 · Cited by 6
“2017 [cited 2019 Feb 21]; 26(7-8):1074-84.”
Periferik İntravenöz Kateter Uygulamasında Hemşirelik Bakımı: Kanıta Dayalı Uygulamalar
ÇELİK, Ş., & Avşar, G. (2021) · Sağlık Bilimleri Üniversitesi Hemşirelik Dergisi · doi:10.48071/sbuhemsirelik.962136 · Cited by 5
Vadgaonkar, A., Kothale, N., Patil, P., Kothari, A. H., & Shetty, Y. C. (2023) · International Emergency Nursing · doi:10.1016/j.ienj.2023.101338 · Cited by 10
Mitra, T. P., Coulter-Nile, S., Jegathees, T., Luong, J., Shetty, A., & Lai, K. (2023) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2023.10.008 · Cited by 5
Homayouni, A., Tabari-Khomeiran, R., & Louyeh, A. A. (2019) · British Journal of Nursing · doi:10.12968/bjon.2019.28.8.s20 · Cited by 11
Higgins, N., Iu, P., Carr, P. J., Ware, R. S., & van Zundert, A. A. J. (2021) · Journal of Clinical Nursing · doi:10.1111/jocn.15654 · Cited by 7
Self-citationLearning Success and Influencing Factors in Out-of-Hospital Placement of Intravenous Catheters
Häske, D., Dorau, W., Eppler, F., Heinemann, N., Hochgreve, B., & Schempf, B. (2022) · Prehospital and Disaster Medicine · doi:10.1017/s1049023x22001327 · Cited by 6
Aytenew, T. M., Belay, D. M., Bayih, W. A., Birhane, B. M., & Alemu, A. Y. (2022) · African Health Sciences · doi:10.4314/ahs.v22i4.72 · Cited by 5
Intravenous access placement and fluid administration appropriateness in the emergency department
Salvetti, M., Paini, A., Colonetti, E., Mutti, C., Bonetti, S., Broggi, A., Bertacchini, F., & Muiesan, M. L. (2021) · Emergency Care Journal · doi:10.4081/ecj.2021.9150 · Cited by 5
Giesen, L., Roest, J. A., Koopman, F. M. A., Deckers, M. M. L., Chon, H., Hackeng, C. M., Riedl, J., de Bruin, M., Katzman, B. M., van Gelder, W., et al. (2026) · Clinical Chemistry · doi:10.1093/clinchem/hvag029 · Cited by 4
Vessel health and preservation: Development and validation of a proactive instrument
Fiorini, J., Piredda, M., Zaghini, F., Venturini, G., Colella, S., Conti, F., Denton, A., & Sili, A. (2021) · Collegian Journal of the Royal College of Nursing Australia · doi:10.1016/j.colegn.2021.02.005 · Cited by 4
Ultraschallgesteuerte periphere Venenpunktion bei schlechtem Venenstatus
Litz, R. J., Radny, D., Feigl, G. C., Mäcken, T., Schwarzkopf, P., & Röhl, A. B. (2023) · Notfall + Rettungsmedizin · doi:10.1007/s10049-023-01171-8 · Cited by 4
A device for improving the visual clarity and dimension of veins
Asrar, M., Al‐Habaibeh, A., Shakmak, B., & Shaw, S. J. (2018) · British Journal of Nursing · doi:10.12968/bjon.2018.27.19.s26 · Cited by 4
Nye, M., Sweeny, A. L., Watkins, S., Ingold, J., & Sharwood, P. F. (2020) · Vascular Access · doi:10.33235/va.6.1.5-9 · Cited by 5
Jacob, A. M., Coventry, L. L., Davies, H. T., & Jacob, E. R. (2020) · Nursing Open · doi:10.1002/nop2.559 · Cited by 4
Vein Location and Feature Detection using Image Analysis
Godoy, R. I. U., Panzo, E. G. V., & Cruz, J. C. D. (2021) · International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM) · doi:10.1109/elticom53303.2021.9590107 · Cited by 4
Intravenous Therapy: Nursing Students’ Knowledge and Confidence
Kaliyaperumal, R., Jeyapaul, S., & Chellathurai, A. (2023) · International Journal of Health Sciences and Research · doi:10.52403/ijhsr.20230611 · Cited by 7
A Noninvasive Vein Finder Based on a Tuned Microwave Loop Resonator
Bing, S., Chawang, K., & Chiao, J. ‐. (2024) · IEEE Journal of Microwaves · doi:10.1109/jmw.2024.3427726 · Cited by 5
Ultrasound guidance versus landmark method for peripheral venous cannulation in adults
Tada, M., Matsumoto, T., Takeda, C., Yamada, N., Furukawa, T. A., & Watanabe, N. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013434 · Cited by 6
Mason, M., Wallis, M. C., Barr, N., Bernard, A., & Lord, B. (2022) · Australasian Emergency Care · doi:10.1016/j.auec.2022.05.003 · Cited by 3
Raut, B., Saluja, S., Soni, A., & Modi, M. (2022) · Journal of the Dow University of Health Sciences · doi:10.36570/jduhs.2022.3.1602 · Cited by 3
Predicting difficult peripheral venous access in hospitalized adult patients: A scoping review
Nannini, F., Mancin, S., Morales Palomares, S., Pettinari, G., Cosmai, S., Lopane, D., Cattani, D., & Mazzoleni, B. (2026) · The Journal of Vascular Access · doi:10.1177/11297298251374415 · Cited by 2
Büyükyılmaz, F., Şendir, M., Kuş, B., & Güçlü, H. Y. (2020) · Contemporary Nurse · doi:10.1080/10376178.2020.1801351 · Cited by 3
Gerçeker, G. Ö., YILDIRIM, B. G., Önal, A., Ören, H., Olgun, H. N., & Bektaş, M. (2023) · European Journal of Oncology Nursing · doi:10.1016/j.ejon.2023.102430 · Cited by 2
Sharma, S. (2023) · Indian Journal of Design Engineering · doi:10.54105/ijde.a8026.083223 · Cited by 2
Xu, H. G., Corley, A., Young, E., Doubrovsky, A., Ware, R. S., Afoakwah, C., Wang, C., Stirling, S., & Marsh, N. M. (2024) · Academic Emergency Medicine · doi:10.1111/acem.15004 · Cited by 2
Urbina, A., Juvé‐Udina, M., Adamuz, J., González‐Samartino, M., Jiménez‐Martínez, E., Delgado‐Hito, P., & Romero‐García, M. (2024) · BMJ Open · doi:10.1136/bmjopen-2024-090101 · Cited by 4
Azam, K., Shahzad, K., Anwar, N., & Zia, S. (2019) · Cureus · doi:10.7759/cureus.5452 · Cited by 2
Faris, G. O., Abdulkareem, A. G., Ismael, N. H., & Qader, D. J. (2023) · BMC Nursing · doi:10.1186/s12912-023-01349-y · Cited by 2
Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis
Mussa, B., Passarella, G., Marchese, M., & Defrancisco, B. (2026) · Medicina · doi:10.3390/medicina62030604 · Cited by 2
Ultraschallgesteuerte periphere Venenpunktion bei schlechtem Venenstatus
Litz, R. J., Radny, D., Feigl, G. C., Mäcken, T., Schwarzkopf, P., & Röhl, A. B. (2023) · Die Anaesthesiologie · doi:10.1007/s00101-022-01228-2 · Cited by 7
Mifflin, N., Alexandrou, E., & Carr, P. J. (2024) · Springer eBooks · doi:10.1007/978-3-031-48576-3_13 · Cited by 2
Self-citationCharacteristics of Peripheral Intravenous Catheter Cannulation in Older Japanese Inpatients
Kitada, M., Yamamura, S., Ninomiya, A., Kabashima, M., Tateno, K., & Hori, E. (2024) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000564 · Cited by 1
Impacto de los equipos hospitalarios multiprofesionales de acceso vascular guiado por ecografía
Dobrzynska, A., Aguilera-Cobos, L., Isabel‐Gómez, R., & Blasco‐Amaro, J. A. (2025) · doi:10.52766/fdhg5715 · Cited by 1
Singleton, L., Sumners, L., Chunn, B., Jupiter, A., Garudadri, P., Okafor, C. C., & Odunayo, A. (2025) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.25.03.0212 · Cited by 2
Peripheral Intravenous Catheters for Hospitalised Older People: A Scoping Review
Howell, N., Marsh, N. M., Mason, M., & Craswell, A. (2025) · International Journal of Older People Nursing · doi:10.1111/opn.70049 · Cited by 1
Drugeon, B., Rickard, C. M., Peters, N., Chopra, V., & Mimoz, O. (2025) · Journal of Advanced Nursing · doi:10.1111/jan.70347 · Cited by 2
Self-citationNacci, A. D. (2018) · International Journal of Studies in Nursing · doi:10.20849/ijsn.v3i3.517 · Cited by 1
Paxton, J. H., Szydlowski, B. A., & Coddington, C. G. (2021) · Springer eBooks · doi:10.1007/978-3-030-77177-5_10 · Cited by 2
The potential role of through the needle PIVC insertion in reducing early catheter contamination
Anstett, M., & Brainard, R. E. (2023) · British Journal of Nursing · doi:10.12968/bjon.2023.32.14.s30 · Cited by 1
Lee, R. K., Kim, D. H., Kim, T., Kang, C., Lee, S. H., Jeong, J. H., Rhee, D. Y., Kim, M. J., & Kim, S. C. (2017) · Pediatric Emergency Medicine Journal · doi:10.22470/pemj.2017.00136 · Cited by 1
ANÁLISE DO CONCEITO DE INSUCESSO DA CATETERIZAÇÃO INTRAVENOSA PERIFÉRICA EM CRIANÇAS HOSPITALIZADAS
Damasceno, J. A. (2017) · Anais dos Seminários de Iniciação Científica · doi:10.13102/semic.v0i21.2584
Lidetu, T., & Yirga, A. (2022) · Research Square · doi:10.21203/rs.3.rs-1989630/v1
The Potential Role of through the Needle PIVC Insertion in Reducing Early Catheter ContaminationCE
Anstett, M., & Brainard, R. E. (2023) · Journal of the Association for Vascular Access · doi:10.2309/java-d-22-00028
Metadata
- Authors
- Carr, P. J., Rippey, J. C. R., Budgeon, C. A., Cooke, M. L., Higgins, N., & Rickard, C. M.
- Affiliations
- Griffith University (AU)
- The University of Western Australia (AU)
- Corresponding author
- Carr, Peter J.
- Venue
- The Journal of Vascular Access
- Publisher
- SAGE Publications
- Published
- 2015-04-12
- Volume
- 17
- Issue
- 2
- Pages
- 182-190
- ISSN
- 1129-7298 (ISSN-L)
- 1724-6032
- OpenAlex
- W2231619733
- Semantic Scholar
- 69e313ec7c604bc9060ef259c7eaf573e012d390
- Cited by
- 122
- References
- 38
- Citations by year
- 2026: 8 · 2025: 7 · 2024: 16 · 2023: 21 · 2022: 9 · 2021: 14 · 2020: 11 · 2019: 17 · 2018: 13 · 2017: 4 · 2016: 2
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The Journal of Vascular Access (publishedVersion)
- PubMed (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- Griffith Research Online (submittedVersion)
- Faculty of Health; Institute of Health and Biomedical Innovation
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Keywords
- peripheral venous cannulation, emergency department, antecubital fossa, insertion site, patient factors, clinician factors, clinician experience, venipuncture, emaciation, body weight
- MeSH terms
- Adult, Aged, Aged, 80 and over, Catheterization, Peripheral, Catheters, Indwelling, Emergency Service, Hospital, Equipment Design, Female, Humans, Male, Middle Aged, Prospective Studies, Risk Factors, Multivariate Analysis, Logistic Models, Odds Ratio, Treatment Failure, Central Venous Catheters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.