The Use of Osteoconductive Bone Graft Substitutes in Orthopaedic Trauma
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Several bone graft substitutes are now available for use in augmenting bone healing following trauma. Many of these products are osteoconductive and are indicated for filling bone defects in conjunction with standard methods of internal and external fixation. Osteoconduction refers to a process in which the three-dimensional structure of a substance is conducive for the ongrowth and/or ingrowth of newly formed bone. Currently used bone graft substitutes that primarily offer osteoconductive properties include coralline hydroxyapatite, collagen-based matrices, calcium phosphate, calcium sulfate, and tricalcium phosphate. These products vary considerably in chemical composition, structural strength, and resorption or remodeling rates. Understanding these differences is important in selecting a bone graft substitute with the properties desired for a specific clinical situation. The limited number of clinical studies and lack of direct-comparison studies between these products require the surgeon to fully understand the properties of each product when choosing a bone graft substitute.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Synthetic bone graft substitutes
Moore, W. R., Graves, S. E., & Bain, G. I. (2001) · ANZ Journal of Surgery · doi:10.1046/j.1440-1622.2001.02128.x · Cited by 826
Hydroxyapatite formed from Coral Skeletal Carbonate by Hydrothermal Exchange
ROY, D. M., & LINNEHAN, S. K. (1974) · Nature · doi:10.1038/247220a0 · Cited by 667 · cited 1×
“The coral is subjected to high pressure and heated in an aqueous phosphate solution, thus converting the calcium carbonate coral skeleton into hydroxyapatite (C10[PO4]6[OH]2).(10) Animal and human studies have shown that vascular and fibrous tissue invade the pore structures and are subsequently converted to mature la…”
Alternatives to Autogenous Bone Graft: Efficacy and Indications
Gazdag, A. R., Lane, J. M., Glaser, D., & Forster, R. A. (1995) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-199501000-00001 · Cited by 612
Hydroxyapatite and Tricalcium Phosphate Bone Graft Substitutes
Bucholz, R. W., Carlton, A., & Holmes, R. E. (1987) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)30395-3 · Cited by 363
Biomechanical and Histological Evaluation of a Calcium Phosphate Cement*
FRAKENBURG, E. P., GOLDSTEIN, S. A., BAUER, T. W., HARRIS, S. A., & POSER, R. D. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199808000-00004 · Cited by 362
Nonallograft Osteoconductive Bone Graft Substitutes
Bucholz, R. W. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200202000-00006 · Cited by 356
Kelly, C. M., Wilkins, R. M., Gitelis, S., Hartjen, C., Watson, J. T., & Kim, P. T. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200101000-00008 · Cited by 353
Interporous Hydroxyapatite as a Bone Graft Substitute in Tibial Plateau Fractures
BUCHOLZ, R. W., CARLTON, A., & HOLMES, R. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198903000-00008 · Cited by 333
Porous hydroxyapatite as a bone-graft substitute in metaphyseal defects. A histometric study.
Holmes, R. E., Bucholz, R. W., & Mooney, V (1986) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198668060-00013 · Cited by 305
A Coralline Hydroxyapatite Bone Graft Substitute: Preliminary Report
HOLMES, R., MOONEY, V., BUCHOLZ, R., & TENCER, A. (1984) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198409000-00036 · Cited by 266
Degradation characteristics of α and β tri‐calcium‐phosphate (TCP) in minipigs
Wiltfang, J., Merten, H. A., Schlegel, K. A., Schultze‐Mosgau, S., Kloss, F. R., Rupprecht, S., & Kessler, P. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10084 · Cited by 255
CHAPMAN, M. W., BUCHOLZ, R., & CORNELL, C. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00004 · Cited by 228
Current Understanding of Osteoconduction in Bone Regeneration
Cornell, C. N., & Lane, J. M. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00027 · Cited by 173
OSTEOCONDUCTIVE MATERIALS AND THEIR ROLE AS SUBSTITUTES FOR AUTOGENOUS BONE GRAFTS
Cornell, C. N. (1999) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(05)70112-7 · Cited by 167
Osteoblast adherence and resorption activity of isolated osteoclasts on calcium sulphate hemihydrate
Sidqui, M., Collin, P., Vitté, C., & Forest, N. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91048-4 · Cited by 153
Treatment of fractures of the distal radius with a remodellable bone cement
Sánchez‐Sotelo, J., Munuera, L., & Madero, R. (2000) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.82b6.0820856 · Cited by 150
Lobenhoffer, P. P., Gerich, T., Witte, F., & Tscherne, H. (2002) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200203000-00001 · Cited by 148
Calcium Sulfate Bone Void Filler: A Review and a Look Ahead
Pietrzak, W. S., & Ronk, R. (2000) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200011040-00009 · Cited by 128
Use of a Collagen-Hydroxyapatite Matrix in Spinal Fusion
Tay, B. K.-B., Le, A. X., Heilman, M., Lotz, J. C., & Bradford, D. S. (1998) · Spine · doi:10.1097/00007632-199811010-00005 · Cited by 114
The Use of BoneSource Hydroxyapatite Cement for Traumatic Metaphyseal Bone Void Filling
Dickson, K. F., Friedman, J., Buchholz, J. G., & Flandry, F. D. (2002) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200212000-00012 · Cited by 85
Tricalcium Phosphate as a Bone Graft Substitute in Trauma
McAndrew, M. P., Gorman, P. W., & Lange, T. A. (1988) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-198802040-00011 · Cited by 80
Cited by
Fernandez de Grado, G., Keller, L., Idoux-Gillet, Y., Wagner, Q., Musset, A.-M., Benkirane-Jessel, N., Bornert, F., & Offner, D. (2018) · Journal of Tissue Engineering · doi:10.1177/2041731418776819 · Cited by 912
Biodegradable Materials for Bone Repair and Tissue Engineering Applications
Sheikh, Z., Najeeb, S., Khurshid, Z., Verma, V., Rashid, H., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095273 · Cited by 782
Roberts, T. T., & Rosenbaum, A. J. (2012) · Organogenesis · doi:10.4161/org.23306 · Cited by 773
Bone Grafts and Substitutes in Dentistry: A Review of Current Trends and Developments
Zhao, R., Yang, R., Cooper, P. R., Khurshid, Z., Shavandi, A., & Ratnayake, J. (2021) · Molecules · doi:10.3390/molecules26103007 · Cited by 641
Tissue Engineering of Bone: Material and Matrix Considerations
Khan, Y., Yaszemski, M. J., Mikos, A. G., & Laurencin, C. T. (2008) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.01260 · Cited by 481
Metadata
- Authors
- Hak, D. J.
- Venue
- Journal of the American Academy of Orthopaedic Surgeons
- Published
- 2007-09
- Volume
- 15
- Issue
- 9
- Pages
- 525-536
- ISSN
- 1067-151X (ISSN-L)
- OpenAlex
- W2187063217
- Cited by
- 244
- References
- 22
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.