Intravascular catheter associated sepsis: a common problem
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To estimate the number of episodes of intravascular catheter associated sepsis that occur in Australia per year. DESIGN AND SETTING: Data were collected from 15 Australian hospitals (mainly tertiary referral hospitals). All positive results of blood cultures were followed up and the primary sepsis site identified and recorded. The average study period was 1.2 years. RESULTS: Eight hundred and nine episodes of systemic sepsis associated with intravascular catheters were identified from 4957 separate episodes of bacteraemia or fungaemia. Of those in which the catheter site was known, there were 491 episodes of sepsis associated with central vein catheters and 233 with peripheral vein catheters. Systemic sepsis with peripheral vein catheters occurred with 0.36 of every 1000 catheters purchased, but with central vein catheters it was 23 episodes per 1000 catheters (relative risk, 64; 95% confidence interval, 54-76). In these hospitals, 8.2 episodes of intravascular catheter associated sepsis occurred annually per 100 beds and 1.5 episodes per 1000 admissions. From these figures, at least 3000 cases of intravascular sepsis may occur per year in Australia. CONCLUSIONS: Intravascular catheter sepsis is common. Central vein catheters cause more sepsis than peripheral vein catheters. With the greater use of catheters this problem is likely to increase.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles and Practice of Infectious Diseases.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-818_5 · Cited by 12,025
Maki, D. G., & Ringer, M. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-10-845 · Cited by 497
Infectious Complications of Indwelling Vascular Catheters
Raad, I. I., & Bodey, G. P. (1992) · Clinical Infectious Diseases · doi:10.1093/clinids/15.2.197 · Cited by 446
A Controlled Trial of Scheduled Replacement of Central Venous and Pulmonary-Artery Catheters
Cobb, D. K., High, K. P., Sawyer, R. G., Sable, C. A., Adams, R. B., Lindley, D. A., Pruett, T. L., Schwenzer, K. J., & Farr, B. M. (1992) · New England Journal of Medicine · doi:10.1056/nejm199210083271505 · Cited by 438
Sepsis associated with central vein catheters in critically ill patients
Collignon, P., Soni, N., Pearson, I. Y., Sorrell, T. C., & Woods, P. (1988) · Intensive Care Medicine · doi:10.1007/bf00717995 · Cited by 102
Self-citationSystemic sepsis and intravenous devices: A prospective survey
Collignon, P., Munro, R., & Sorrell, T. C. (1984) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1984.tb132802.x · Cited by 55
Self-citationBacteraemia and Fungaemia in an Australian General Hospital — Associations and Outcomes
McGregor, A., & Collignon, P. (1993) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1993.tb121913.x · Cited by 35
Self-citationCoagulase-Negative Staphylococcal Bacteremia
Collignon, P. (1989) · Annals of Internal Medicine · doi:10.7326/0003-4819-110-11-945_2 · Cited by 3
Self-citation
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Prevention of Intravascular Catheter–Related Infections
Mermel, L. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-5-200003070-00009 · Cited by 919
Guidelines for the Prevention of Intravascular Catheter-Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Pediatrics · doi:10.1542/peds.110.5.e51 · Cited by 738
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Clinical Infectious Diseases · doi:10.1086/344188 · Cited by 440
Safdar, N., & Maki, D. G. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2045-z · Cited by 366
Peripheral venous catheters: an under-evaluated problem
Zingg, W., & Pittet, D. (2009) · International Journal of Antimicrobial Agents · doi:10.1016/s0924-8579(09)70565-5 · Cited by 310
Lorente, L., Henry, C., Martín, M. M., Jiménez, A., & Mora, M. L. (2005) · Critical Care · doi:10.1186/cc3824 · Cited by 307
Coopersmith, C. M., Rebmann, T. L., Zack, J. E., Ward, M. R., Corcoran, R. M., Schallom, M. E., Sona, C. S., Buchman, T. G., Boyle, W. A., Polish, L. B., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200201000-00009 · Cited by 304
Ziegler, M. J., Pellegrini, D. C., & Safdar, N. (2015) · Infection · doi:10.1007/s15010-014-0689-y · Cited by 288
Crnich, C. J., & Maki, D. G. (2002) · Clinical Infectious Diseases · doi:10.1086/339863 · Cited by 264
Short-term Peripheral Venous Catheter–Related Bloodstream Infections: A Systematic Review
Mermel, L. A. (2017) · Clinical Infectious Diseases · doi:10.1093/cid/cix562 · Cited by 253
Intravascular Catheter-Associated Infections
Crump, J. A., & Collignon, P. J. (2000) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s100960050001 · Cited by 252
Self-citationVamvakas, E. C. (1996) · Transfusion · doi:10.1046/j.1537-2995.1996.36296181932.x · Cited by 207
Rosenthal, V. D., Guzman, S., Pezzotto, S. M., & Christopher J, C. (2003) · American Journal of Infection Control · doi:10.1067/mic.2003.52 · Cited by 178
O’Brien, J. M., Ali, N. A., Aberegg, S. K., & Abraham, E. (2007) · The American Journal of Medicine · doi:10.1016/j.amjmed.2007.01.035 · Cited by 177
Wong, K., Cooper, A., Brown, J., Boyd, L., & Levinson, M. (2018) · Journal of Clinical Nursing · doi:10.1111/jocn.13961 · Cited by 32
Metadata
- Authors
- Collignon, P. J., & Sepsis, O. B. O. T. A. S. O. I. C. A.
- Venue
- Medical Journal of Australia
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 161
- Issue
- 6
- Pages
- 374-378
- ISSN
- 0025-729X (ISSN-L)
- 1326-5377
- OpenAlex
- W2404738213
- Cited by
- 179
- References
- 8
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.