Ambulatory blood pressure monitoring
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
End-organ damage associated with hypertension is more closely related to ambulatory blood pressure (ABP) than clinic or casual blood pressure measurements. ABP measurements give better prediction of clinical outcome than clinic or casual blood pressure measurements. The technique of ABP monitoring (ABPM) is specialised; validated monitors and appropriate quality control measures should be used. Interpretation of ABP profile should include mean daytime, night-time (sleep) and 24-hour measurements, and consideration of diary information and time of drug treatment. Reports may also include ABP "loads" (percentage area under the blood pressure curve above set limits) for daytime and night-time periods. Normal blood pressure values for adults are < 135/85 mmHg for daytime, < 120/75 mmHg for night-time, and < 130/80 mmHg for 24 hours. ABPM is indicated to exclude "white coat" hypertension and has a role in assessing apparent drug-resistant hypertension, symptomatic hypotension or hypertension, in the elderly, in hypertension in pregnancy, and to assess adequacy of control in patients at high risk of cardiovascular disease. White coat hypertension requires continued surveillance; patients who display this phenomenon may, in time, develop established hypertension. Appropriate use of ABPM may result in cost savings. Randomised controlled trials comparing management based on clinic or casual versus ABP measurements are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Mancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Cited by
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Disruptive, Soft, Wearable Sensors
Ling, Y., An, T., Yap, L. W., Zhu, B., Gong, S., & Cheng, W. (2020) · Advanced Materials · doi:10.1002/adma.201904664 · Cited by 480
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Bilo, G., Giglio, A., Styczkiewicz, K., Caldara, G., Maronati, A., Kawecka-Jaszcz, K., Mancia, G., & Parati, G. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e32829c6a60 · Cited by 246
Loss of nocturnal blood pressure fall in various extrapyramidal syndromes
Schmidt, C., Berg, D., Herting, Prieur, S., Junghanns, S., Schweitzer, K., Globas, C., Schöls, L., Reichmann, H., & Ziemssen, T. (2009) · Movement Disorders · doi:10.1002/mds.22767 · Cited by 113
Metadata
- Authors
- McGrath, B. P.
- Venue
- Medical Journal of Australia
- Publisher
- AMPCo
- Published
- 2002-06-17
- Volume
- 176
- Issue
- 12
- Pages
- 588-592
- ISSN
- 0025-729X (ISSN-L)
- 1326-5377
- OpenAlex
- W4249538684
- Cited by
- 85
- References
- 2
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.