The Diagnostic Concordance of Whole Slide Imaging and Light Microscopy: A Systematic Review
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Context.— Light microscopy (LM) is considered the reference standard for diagnosis in pathology. Whole slide imaging (WSI) generates digital images of cellular and tissue samples and offers multiple advantages compared with LM. Currently, WSI is not widely used for primary diagnosis. The lack of evidence regarding concordance between diagnoses rendered by WSI and LM is a significant barrier to both regulatory approval and uptake. Objective.— To examine the published literature on the concordance of pathologic diagnoses rendered by WSI compared with those rendered by LM. Data Sources.— We conducted a systematic review of studies assessing the concordance of pathologic diagnoses rendered by WSI and LM. Studies were identified following a systematic search of Medline (Medline Industries, Mundelein, Illinois), Medline in progress (Medline Industries), EMBASE (Elsevier, Amsterdam, the Netherlands), and the Cochrane Library (Wiley, London, England), between 1999 and March 2015. Conclusions.— Thirty-eight studies were included in the review. The mean diagnostic concordance of WSI and LM, weighted by the number of cases per study, was 92.4%. The weighted mean κ coefficient between WSI and LM was 0.75, signifying substantial agreement. Of the 30 studies quoting percentage concordance, 18 (60%) showed a concordance of 90% or greater, of which 10 (33%) showed a concordance of 95% or greater. This review found evidence to support a high level of diagnostic concordance. However, there were few studies, many were small, and they varied in quality, suggesting that further validation studies are still needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy
(2023) · doi:10.1002/9781119756194 · Cited by 757
Pantanowitz, L., Sinard, J. H., Henricks, W. H., Fatheree, L. A., Carter, A. B., Contis, L., Beckwith, B. A., Evans, A. J., Lal, A., & Parwani, A. V. (2013) · Archives of Pathology and Laboratory Medicine · doi:10.5858/arpa.2013-0093-cp · Cited by 620 · cited 13×
“Addressing the need to validate WSI, the College of American Pathologists (CAP) produced 12 guideline statements in 2013 for studies wishing to validate the diagnostic concordance of WSI and LM.(21) Their guidelines included specific recommendations for validation studies: at least 60 routine cases per application, tr…”
BackgroundMethodResultInfluentialQUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Digital Imaging in Pathology: Whole-Slide Imaging and Beyond
Ghaznavi, F., Evans, A., Madabhushi, A., & Feldman, M. (2013) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-011811-120902 · Cited by 459 · cited 1×
“imaging hardware and software have led to the development of whole slide imaging (WSI) devices.(1) These devices”
MethodDigital pathology: current status and future perspectives
Al‐Janabi, S., Huisman, A., & Van Diest, P. J. (2012) · Histopathology · doi:10.1111/j.1365-2559.2011.03814.x · Cited by 363
Cited by
Mukhopadhyay, S., Feldman, M. D., Abels, E., Ashfaq, R., Beltaifa, S., Cacciabeve, N. G., Cathro, H. P., Cheng, L., Cooper, K., Dickey, G. E., et al. (2018) · American Journal of Surgical Pathology · doi:10.1097/pas.0000000000000948 · Cited by 399
Digital Pathology: Advantages, Limitations and Emerging Perspectives
Jahn, S. W., Plass, M., & Moinfar, F. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9113697 · Cited by 348
Digital pathology in clinical use: where are we now and what is holding us back?
Griffin, J., & Treanor, D. (2017) · Histopathology · doi:10.1111/his.12993 · Cited by 263
Self-citationWhole slide imaging equivalency and efficiency study: experience at a large academic center
Hanna, M. G., Reuter, V. E., Hameed, M. R., Tan, L. K., Chiang, S., Sigel, C., Hollmann, T., Giri, D., Samboy, J., Moradel, C., et al. (2019) · Modern Pathology · doi:10.1038/s41379-019-0205-0 · Cited by 215
Relevance of deep learning to facilitate the diagnosis of HER2 status in breast cancer
Vandenberghe, M. E., Scott, M. L. J., Scorer, P. W., Söderberg, M., Balcerzak, D., & Barker, C. (2017) · Scientific Reports · doi:10.1038/srep45938 · Cited by 209
“Although, studies have reported overall good agreement between diagnoses performed with digital and conventional microscopy 41–43 , the effect of the imaging modality on HER2 status diagnosis was not tested here and could potentially contribute to the observed variability between the initial…”
ResultValidation of a digital pathology system including remote review during the COVID-19 pandemic
Hanna, M. G., Reuter, V. E., Ardon, O., Kim, D., Sirintrapun, S. J., Schüffler, P. J., Busam, K. J., Sauter, J. L., Brogi, E., Tan, L. K., et al. (2020) · Modern Pathology · doi:10.1038/s41379-020-0601-5 · Cited by 187
Olsen, T. G., Jackson, B. H., Feeser, T. A., Kent, M. N., Moad, J. C., Krishnamurthy, S., Lunsford, D. D., & Soans, R. E. (2018) · Journal of Pathology Informatics · doi:10.4103/jpi.jpi_31_18 · Cited by 119
The performance of digital microscopy for primary diagnosis in human pathology: a systematic review
Araújo, A. L. D., Arboleda, L. P. A., Palmier, N. R., Fonsêca, J. M., de Pauli Paglioni, M., Gomes-Silva, W., Ribeiro, A. C. P., Brandão, T. B., Simonato, L. E., Speight, P. M., et al. (2019) · Virchows Archiv · doi:10.1007/s00428-018-02519-z · Cited by 64
Digital pathology: Review of current opportunities and challenges for oral pathologists
Liu, Y., & Pantanowitz, L. (2019) · Journal of Oral Pathology & Medicine · doi:10.1111/jop.12825 · Cited by 28
Metadata
- Authors
- Goacher, E., Randell, R., Williams, B., & Treanor, D.
- Venue
- Archives of Pathology & Laboratory Medicine
- Published
- 2017-01
- Volume
- 141
- Issue
- 1
- Pages
- 151-161
- ISSN
- 0003-9985 (ISSN-L)
- 1543-2165
- OpenAlex
- W2460896619
- Cited by
- 173
- References
- 63
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.