CoChat

Validation of the Actiheart Monitor for the Measurement of Physical Activity

Open access
Barreira, Tiago, Kang, Minsoo, Caputo, Jennifer, Farley, Richard, Renfrow, Matthew · 2009 · International Journal of Exercise Science
Cited by 76

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

The Actiheart monitor uniquely allows simultaneous measurement of heart rate and movement counts. The purpose of this study was to establish validity evidence for the Actiheart monitor under laboratory and free-living conditions. A total of 34 college students (17 males and 17 females, age = 21.8 ± 3.6 years) participated in the study. In the laboratory environment, the participants completed three, 5 min bouts of treadmill walking and/or running at speeds of 3.2, 6.4, and 9.6 km/h. Outside the laboratory, participants were asked to perform free-living physical activity for 30 min. For validation, energy expenditure, movement counts, and heart rate measurements from the Actiheart monitor were compared with an AEI Moxus Metabolic Cart, Actigraph accelerometer, Polar heart rate monitor (HRM), and electrocardiogram (ECG), respectively. The Actiheart underestimated energy expenditure only at the highest workload in the laboratory environment compared with the metabolic cart (p = .009). Actiheart heart rate (HR) was similar to the HR measured by ECG at all workloads. Under free-living conditions, the Actiheart energy expenditure was highly correlated (r = .81) with the Actigraph energy expenditure with no significant differences (t(33) =.26; p = .80). Actiheart heart rate was also highly correlated with HR from the Polar HRM (r = .93), however, there was an overestimation of HR by the Actiheart monitor (t(33) = 3.00; p = .005) under free-living conditions. The Actiheart monitor appears to accurately measure physical activity under free-living conditions and at low and moderate intensities in the laboratory environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.70252/ltrb1450

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 76

Metadata

Authors
Barreira, T., Kang, M., Caputo, J., Farley, R., & Renfrow, M.
Venue
International Journal of Exercise Science
Published
2009
Volume
2
Issue
1
Pages
60-71
ISSN
1939-795X (ISSN-L)
OpenAlex
W182709412
Cited by
76
References
10
FWCI
2.36
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of the Actiheart Monitor for the Measurement of Physical Activity. https://app.cochat.ai/papers/10.70252/ltrb1450
The paper
Barreira, T., Kang, M., Caputo, J., Farley, R., & Renfrow, M. (2009). Validation of the Actiheart Monitor for the Measurement of Physical Activity. International Journal of Exercise Science. https://doi.org/10.70252/ltrb1450

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.