The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Quantitative Magnetic Particle Imaging Monitors the Transplantation, Biodistribution, and Clearance of Stem Cells In Vivo
Open accessAbstract
Stem cell therapies have enormous potential for treating many debilitating diseases, including heart failure, stroke and traumatic brain injury. For maximal efficacy, these therapies require targeted cell delivery to specific tissues followed by successful cell engraftment. However, targeted delivery remains an open challenge. As one example, it is common for intravenous deliveries of mesenchymal stem cells (MSCs) to become entrapped in lung microvasculature instead of the target tissue. Hence, a robust, quantitative imaging method would be essential for developing efficacious cell therapies. Here we show that Magnetic Particle Imaging (MPI), a novel technique that directly images iron-oxide nanoparticle-tagged cells, can longitudinally monitor and quantify MSC administration in vivo. MPI offers near-ideal image contrast, depth penetration, and robustness; these properties make MPI both ultra-sensitive and linearly quantitative. Here, we imaged, for the first time, the dynamic trafficking of intravenous MSC administrations using MPI. Our results indicate that labeled MSC injections are immediately entrapped in lung tissue and then clear to the liver within one day, whereas standard iron oxide particle (Resovist) injections are immediately taken up by liver and spleen. Longitudinal MPI-CT imaging also indicated a clearance half-life of MSC iron oxide labels in the liver at 4.6 days. Finally, our ex vivo MPI biodistribution measurements of iron in liver, spleen, heart, and lungs after injection showed excellent agreement (R(2) = 0.943) with measurements from induction coupled plasma spectrometry. These results demonstrate that MPI offers strong utility for noninvasively imaging and quantifying the systemic distribution of cell therapies and other therapeutic agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,163
Looking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Mesenchymal Stem Cell Homing: The Devil Is in the Details
Karp, J. M., & Leng Teo, G. S. (2009) · Cell Stem Cell · doi:10.1016/j.stem.2009.02.001 · Cited by 1,445
Fischer, U. M., Harting, M. T., Jimenez, F., Monzon-Posadas, W. O., Xue, H., Savitz, S. I., Laine, G. A., & Cox, C. S. (2009) · Stem Cells and Development · doi:10.1089/scd.2008.0253 · Cited by 1,292
The Dynamic in vivo Distribution of Bone Marrow-Derived Mesenchymal Stem Cells after Infusion
Gao, J., Dennis, J. E., Muzic, R. F., Lundberg, M., & Caplan, A. I. (2001) · Cells Tissues Organs · doi:10.1159/000047856 · Cited by 952
Gupta, N., Su, X., Popov, B. V., Lee, J. W., Serikov, V. B., & Matthay, M. A. (2007) · The Journal of Immunology · doi:10.4049/jimmunol.179.3.1855 · Cited by 933
Bone Marrow–Derived Mesenchymal Stem Cells in Repair of the Injured Lung
Rojas, M., Xu, J., Woods, C. R., Mora, A. L., Spears, W., Roman, J., & Brigham, K. L. (2005) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2004-0330oc · Cited by 849
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Eggenhofer, E., Benseler, V., Kroemer, A., Popp, F. C., Geissler, E. K., Schlitt, H. J., Baan, C. C., Dahlke, M. H., & Hoogduijn, M. J. (2012) · Frontiers in Immunology · doi:10.3389/fimmu.2012.00297 · Cited by 804
Schlomka, J., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 803
Flagged first, then by citations
Cited by
Sorted by citations
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,084
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Magnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer Detection
Yu, E. Y., Bishop, M. D., Zheng, B., Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Krishnan, K. M., Goodwill, P. W., & Conolly, S. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b04865 · Cited by 379
Israel, L. L., Galstyan, A., Holler, E., & Ljubimova, J. Y. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.01.009 · Cited by 343
“Another study used quantitative MPI to monitor transplantation, bio-distribution, and clearance of ferucarbotran-labelled human stem cells in vivo [151].”
Background
Metadata
- Authors
- Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M.
- Affiliations
- University of California, Berkeley (US)
- Corresponding author
- Zheng, Bo
- ORCID
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2016
- Volume
- 6
- Issue
- 3
- Pages
- 291-301
- ISSN
- 1838-7640 (ISSN-L)
- PMC
- PMC4737718
- OpenAlex
- W2275153700
- Cited by
- 322
- References
- 53
- Citations by year
- 2026: 18 · 2025: 25 · 2024: 29 · 2023: 36 · 2022: 37 · 2021: 35 · 2020: 34 · 2019: 30 · 2018: 30 · 2017: 35 · 2016: 13
- FWCI
- 12.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- Theranostics (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- tub.dok (Hamburg University of Technology) (submittedVersion, cc-by-nc)
- TUHH Open Research
- Funders
- W. M. Keck Foundation (009323)
- ACT Government
- Siebel Scholars Foundation
- National Institutes of Health (009323, NIH-R01)
- National Institute of Mental Health (R24MH106053)
- National Institute of Biomedical Imaging and Bioengineering (R01EB019458, R01EB013689)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Mesenchymal stem cell research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- magnetic particle imaging, mesenchymal stem cells, stem cell transplantation, cell biodistribution, cell clearance, stem cell therapy
- MeSH terms
- Animals, Diagnostic Imaging, Female, Ferric Compounds, Humans, Magnetics, Rats, Inbred F344, Staining and Labeling, Tissue Distribution, Mesenchymal Stem Cell Transplantation, Mice, Nanoparticles, Administration, Intravenous
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review