The DOI matches its Crossref record; 134 of the 134 references it cites were found in a registry or an index.
Use of Ambulatory Electrocardiographic (Holter) Monitoring
Abstract
PURPOSE: To evaluate the clinical efficacy of ambulatory electrocardiographic (ECG) monitoring and to develop guidelines for its use in clinical practice. DATA IDENTIFICATION: Studies reported since January 1978 were identified both through computer searches using Index Medicus and extensive manual searching of bibliographies of identified articles. STUDY SELECTION: Only studies that fulfilled methodologic criteria designed to limit bias were reviewed. DATA EXTRACTION: Information describing population and study results was assessed in four major categories (variability, diagnosis, prognosis, and therapy guidance) for both arrhythmia monitoring and ST-segment analysis. RESULTS OF DATA ANALYSIS: The day-to-day variability of arrhythmia and myocardial ischemia detected by ambulatory ECG monitoring may be considerable in an individual patient. Caution must therefore be used in interpreting serial tests. Ambulatory ECG monitoring with diary correlation permits documentation of cardiac arrhythmias causing symptoms, but the diagnostic yield is low unless symptoms are frequent. Such monitoring can provide information about prognosis in patients after acute myocardial infarction. The amount of prognostic information obtained is modest and is outweighed by other measures. There is insufficient information to make conclusions about such monitoring and prognosis in other conditions. Serial ambulatory ECG monitoring may be used to assess the effect of an antiarrhythmic drug in patients with frequent and reproducible ventricular ectopy. The effect of arrhythmia suppression on survival is uncertain. Because of its low sensitivity and specificity, analysis of ST-segment changes during ambulatory ECG monitoring is inaccurate in establishing or excluding the presence of coronary disease. Although anti-ischemic interventions reduce the frequency and duration of ST-segment changes on monitoring, there are no data on the utility of using reduction or elimination of the changes as the endpoint of therapy. CONCLUSIONS: Ambulatory ECG monitoring can provide diagnostic, prognostic, and therapeutic information in many situations, but similar information often may be better obtained in other ways.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In a meta-analysis of seven studies conducted on patients with syncope and/or palpitations of unknown origin, Holter monitoring has been seen to have a sensitivity value of only 22%.82”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [82]
Citations
Cites
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Clinical Epidemiology: A Basic Science for Clinical Medicine.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-825_9 · Cited by 3,497
The Cardiac Arrhythmia Suppression Trial (CAST) Investigators (1989) · New England Journal of Medicine · doi:10.1056/nejm198908103210629 · Cited by 3,289
Risk Stratification and Survival after Myocardial Infarction
The Multicenter Postinfarction Research Group (1983) · New England Journal of Medicine · doi:10.1056/nejm198308113090602 · Cited by 1,599
Bigger, J. T., Fleiss, J. L., Kleiger, R. E., Miller, J. P., & Rolnitzky, L. M. (1984) · Circulation · doi:10.1161/01.cir.69.2.250 · Cited by 1,286
Approaches to Sudden Death from Coronary Heart Disease
Lown, B., & Wolf, M. A. (1971) · Circulation · doi:10.1161/01.cir.44.1.130 · Cited by 1,258
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Deanfield, J. E., Selwyn, A. P., Chierchia, S. L., Maseri, A., Ribeiro, P., Krikler, S. J., & Morgan, M. K. (1983) · The Lancet · doi:10.1016/s0140-6736(83)92295-x · Cited by 718
Silent Ischemia as a Marker for Early Unfavorable Outcomes in Patients with Unstable Angina
Gottlieb, S. O., Weisfeldt, M. L., Ouyang, P., Mellits, E. D., & Gerstenblith, G. (1986) · New England Journal of Medicine · doi:10.1056/nejm198605083141903 · Cited by 673
Long-Term Follow-up of Asymptomatic Healthy Subjects with Frequent and Complex Ventricular Ectopy
Kennedy, H. L., Whitlock, J. A., Sprague, M. K., Kennedy, L. J., Buckingham, T. A., & Goldberg, R. J. (1985) · New England Journal of Medicine · doi:10.1056/nejm198501243120401 · Cited by 628
Research works printed but not linked: 16
- Sheffield L, 1985, Circulation., 71, 626A
- Hertzeanu H, 1979, Acta Cardiol., 34, 375
- Gendelman H, 1983, N Y State J Med., 83, 1161
- Eagle K, 1983, Yale J Biol Med., 56, 1
- Diamond T, 1983, S Afr Med J., 63, 5
- DiMarco J, 1987, Circulation., 75, III
- 10.1001/jama.1967.03120030092017 · DOI
- Lie K, 1974, Eur J Cardiol., 1, 379
- Lovell R, 1971, Lancet., 2, 1055
- Hugenholtz P, 1978, Management of Ventricular Tachycardia:Role of Mexiletine., 572
- Nicklas J, 1988, Circulation., 78, II27A
- Lichstein E, 1983, Circulation., 67, I
- Tamaki N, 1986, J Nucl Med., 27, 911A
- 1975, Circulation., 52, 11
- 10.1016/S0140-6736(83)92295-X · DOI
- 10.1001/jama.1988.03720070030029 · DOI
Cited by
Sorted by citations
Items 101–175 of 175
Monitoring of Atrial Tachyarrhythmias
Mehra, R. (2002) · Cardiac Electrophysiology Review · doi:10.1023/a:1016372823942 · Cited by 3
Kim, M.-G., Zhang, G., Li, M., & Jung, J. (2025) · IEEE Access · doi:10.1109/access.2025.3612961 · Cited by 2
The global morphological analysis of a time-delay embedding of the scalar time series
Ćosić, M., & Miljković, N. (2024) · Nonlinear Dynamics · doi:10.1007/s11071-024-09750-1 · Cited by 2
12-Lead ECG Reconstruction via Koopman Operators
Golany, T., Radinsky, K., Freedman, D. Z., & Minha, S. (2021) · International Conference on Machine Learning · Cited by 2
Actualizaciones en neurología infantil IV
Arroyo, H. A., Ruggieri, V. L., Campistol, J., & Campos, J. B. (2013) · Medicina-buenos Aires · Cited by 2
Evaluation of Patients with Palpitations: Cardiac Event Recorder Versus 48‐hour Holter Monitoring
Makowska, E., Szymot, J., Soszyriska, M., & Kułakowski, P. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00068.x · Cited by 2
Setting up a falls and syncope service for the elderly
O’Shea, D. (2002) · Clinics in Geriatric Medicine · doi:10.1016/s0749-0690(02)00009-5 · Cited by 2
Brunetti, N. D., D’Arienzo, G., Tiscia, G., Pellegrino, P. L., Gennaro, L. D., & Biase, M. D. (2007) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.02.055 · Cited by 2
Externe und implantierbare Ereignisrekorder zum Event-Recording in der Synkopendiagnostik
Seidl, K., Vater, M., & Senges, J. (2002) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-002-0340-y · Cited by 2
Diagnosis and Management of Syncope
Karabin, B. L., & Grubb, B. P. (2011) · Wiley eBooks · doi:10.1002/9781118788967.ch16 · Cited by 2
Syncope: How Should It Be Evaluated Today?
Kapoor, W. N. (1998) · Springer eBooks · doi:10.1007/978-88-470-2288-1_52 · Cited by 2
Evaluation and Management of Syncope
Grubb, B. P., & KOSINSKI, D. J. (2002) · Contemporary cardiology · doi:10.1007/978-1-59259-090-2_10 · Cited by 2
La gestione del paziente con palpitazioni
Giada, F., Inama, G., Bertaglia, M., Pedrinazzi, C., Gulizia, M. M., Ricci, R. P., & Raviele, A. (2010) · Giornale italiano di cardiologia · doi:10.1714/568.6749 · Cited by 2
Monitoring Long-term Cardiac Activity with Contactless Radio Frequency SignalsPreprint
Chen, Y., Zhang, B.-B., Zhang, D., Li, Y., Lu, Z. P., Chen, J., Wang, H., Zhou, F., Pu, Y., Hu, Y., et al. (2024) · Research Square · doi:10.21203/rs.3.rs-4456442/v1 · Cited by 2
Chiang, L.-K. (2017) · Journal of Family Medicine and Health Care · doi:10.11648/j.jfmhc.20170301.13 · Cited by 1
Doku, A., Ndanu, T. A., Asiamah-Asare, B. K. Y., Antwi‐Boasiako, C., & Kpodonu, J. (2018) · Ghana Medical Journal · doi:10.4314/gmj.v52i4.7 · Cited by 1
Wearable PPG-to-Multi-Lead ECG Conversion for Cardiac Monitoring
Zhong, C., Guo, Z., Gehi, A. K., Xu, C., & Li, H. (2025) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn66969.2025.11337909 · Cited by 1
ECG Telemetry and Long Term Electrocardiography
Greenstein, E., & Rosenthal, J. E. (2010) · Springer eBooks · doi:10.1007/978-1-84882-515-4_18 · Cited by 1
Clinical Logistics in 24-Hour Ambulatory Electrocardiographic Monitoring
RuDusky, B. M. (2003) · Angiology · doi:10.1177/000331970305400508 · Cited by 1
« Malaise », lipothymie et syncope
Lestavel, P., & Marquié, C. (2006) · EMC - Médecine d urgence · doi:10.1016/s1959-5182(06)73437-7 · Cited by 1
van Weert, H. C. P. M. (2013) · Bijblijven · doi:10.1007/s12414-013-0075-1 · Cited by 1
Ambulatory Electrocardiography
(2008) · Elsevier eBooks · doi:10.1016/b978-141603774-3.10027-9 · Cited by 1
Bomfim, F. N. G., & Almeida-Santos, M. A. (2021) · Research Society and Development · doi:10.33448/rsd-v10i15.23070 · Cited by 1
Lucassen, W. A. M., Himmelreich, J. C. L., Harskamp, R. E., & Selder, J. L. (2021) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-368-2620-4_30 · Cited by 1
Karki, B., Ghimire, J. P., Nepal, B., Mahaseth, A., Sah, A., Pandit, S., Pandey, N. K., Shah, P. K., & Karki, P. (2022) · Nepal Mediciti Medical Journal · doi:10.3126/nmmj.v3i1.48523 · Cited by 1
Recurrence of thymoma presenting as a superior vena cava syndrome
Lefèbvre, P., LELEUX, A., & Philippart, C. (1999) · Heart · doi:10.1136/hrt.81.4.433 · Cited by 1
Use of claims data for determining the appropriateness of ambulatory cardiac monitoring
Shulkin, D. J., Lieberman, J., Morganroth, J., & Schwartz, J. S. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)91022-a · Cited by 1
Mori, N., Hara, M., Miyake, F., Sato, C., Murayama, M., Tamamura, K., Kaneko, M., & Sirakawa, O. (2000) · Japanese Circulation Journal-english Edition · doi:10.1253/jcj.64.583 · Cited by 1
Kapoor, W. N. (2006) · Springer eBooks · doi:10.1007/0-387-22621-4_65 · Cited by 1
Sensor Integration for Behavior Monitoring
Chaspari, T. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00161-8 · Cited by 1
Cardiovascular Evaluation of Patients with Syncope of Uncertain Etiology
Grubb, B. P., & KOSINSKI, D. J. (1997) · Cardiac Electrophysiology Review · doi:10.1023/a:1009933417529 · Cited by 1
Arritmias hipoactivas. Bloqueos auriculoventriculares
Alberola, A. G., Snchez, J. M., Mas, M. V., & Chvarri, M. V. (2005) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/s0211-3449(05)73740-1
Schwindel aus neurologischer Sicht
Lempert, T. (2007) · Springer eBooks · doi:10.1007/978-3-540-47448-7_13
A case of mistaken mesial temporal identity
Neligan, A., Holdright, D. R., Rugg‐Gunn, F. J., & Sander, J. W. A. S. (2009) · BMJ · doi:10.1136/bmj.b2258
Stellenwert des implantierbaren Looprekorders im Rahmen der Diagnostik von Synkopen
Ehlers, C., Brüggemann, T., Wiedemann, M., & Andresen, D. (2000) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s003990070006
Díaz, J. P., Rodrigo Trallero, G., Val, A. S., & Montero, I. J. F. (2002) · Clínica e Investigación en Arteriosclerosis · doi:10.1016/s0214-9168(02)78832-3
Il cardiopalmo: iter diagnostico
Giada, F., & Raviele, A. (2010) · Giornale italiano di cardiologia · doi:10.1714/660.7680
Laksomya, T., Krittayaphong, R., Winijkul, A., & Yindeengam, A. (2010)
Comparison of Various Cardiac Event Recorders Clinically Available in Japan
Nakamura, H., Yasuda, S., Odashiro, K., Kaji, Y., & Maruyama, T. (2007) · JOURNAL OF HEALTH SCIENCE
Long-Term ECG (Holter) Monitoring and Head-Up Tilt Test
Dora, S. K. (2013) · Springer eBooks · doi:10.1007/978-1-4471-5316-0_12
The Stacked Frame Display for the Rapid Review and Analysis of Data
Warner, R. A. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-804513-8.00005-5
An Audit of Utilisation of Holter Tape Facilities at Glasgow Royal Infirmary
Sedgewick, M. L., Khalid, I., Cunningham, M., & Cobbe, S. M. (1994) · Scottish Medical Journal · doi:10.1177/003693309403900108
Augustyniak, P., & Tadeusiewicz, R. (2009) · IGI Global eBooks · doi:10.4018/978-1-60566-080-6.ch003
Evaluation of Syncope in the Elderly Patient
Stugensky, K. M., Neuberg, G. W., & Maurer, M. S. (2008) · Fundamental and clinical cardiology · doi:10.3109/9781420061710.026
Erste Erfahrungen über den diagnostischen Nutzen eines implantierbaren
Seidl, K., Breunung, S., Rameken, M., Siemon, G., Schwacke, H., Drögemüller, A., Zahn, R., Senges, J., & Verlag, S. (2000)
Krausova, R. (2005) · Intervenční a akutní kardiologie
SUDDEN CARDIAC DEATH: MECHANISMS AND REASONS, RISK FACTORS, TREATMENT AND PREVENTION
Aleynikova, T. V. (2017) · Health and Ecology Issues · doi:10.51523/2708-6011.2017-14-2-3
LONG-TERM AMBULATORY ECG MONITORING AN ESSENTIAL DIAGNOSTIC TOOL FOR CURRENT TIMES
Ali, P. S., Raza, S. H., & Mansoor, S. (2022) · Pakistan Heart Journal · doi:10.47144/phj.v54i4.2117
Ambulatory Electrocardiogram Monitoring
Hombach, V. (2011) · Springer eBooks · doi:10.1007/978-0-85729-880-5_1
Kapoor, W. N. (1997) · Springer eBooks · doi:10.1007/978-1-4757-2705-0_49
van Weert, H. C. P. M., & Peters, R. J. G. (2016) · Kernboek · doi:10.1007/978-90-368-1274-0_24
van Weert, H. (2003) · Huisarts en Wetenschap · doi:10.1007/bf03083202
Kline, H. J. (2014) · Personalized Medicine Universe · doi:10.1016/j.pmu.2014.02.001
Morillo, C. A., & Expósito-García, V. (2009) · Springer eBooks · doi:10.1007/978-1-84882-927-5_3
van Weert, H. C. P. M., & Peters, R. J. G. (2011) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-8364-1_24
van Weert, H. C. P. M., & Peters, R. J. G. (2007) · Bohn Stafleu van Loghum eBooks · doi:10.1007/978-90-313-6530-2_28
Ambulatory Electrocardiography
Rho, R. W., & Page, R. L. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00071-5
Bénali, K., & Guénancia, C. (2022) · EMC - Tratado de Medicina · doi:10.1016/s1636-5410(22)46832-2
Bénali, K., & Guénancia, C. (2022) · EMC - AKOS - Trattato di Medicina · doi:10.1016/s1634-7358(22)46915-4
Video-based Estimation of Blood PressurePreprint
Tucker, C. S., Dasari, A., & Jeni, L. A. (2023) · Research Square · doi:10.21203/rs.3.rs-3374093/v1
FECG: A Flexible Holter for Ambulatory Heart Rate Monitoring
Shan, Y., Liu, T., & Liu, Z. (2024) · Studies in computational intelligence · doi:10.1007/978-3-031-50381-8_85
Nwafor, C. E., & Briggs, O. (2024) · Asian Journal of Medicine and Health · doi:10.9734/ajmah/2024/v22i61014
Dehankar, P., & Das, S. (2024) · Advances in medical technologies and clinical practice book series · doi:10.4018/979-8-3693-2762-3.ch013
Noise Reduction in Capacitive ECG Measurements by Dedicated Modelling and Kalman Filtering
Lin, R., Wu, Y., Cheng, A., Xu, Y., & Xu, L. (2024) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea60663.2024.10596907
İmplante Edilebilir Kardiyak Elektronik Cihazlar
Arslan, G. Y., Hoşoğlu, Y., Hoşoğlu, A., Yiğit, Y., Akgün, D. E., Akgün, Y. S., Yıldırım, T., Yıldırım, S. E., Yazar, A., Danışman, N., et al. (2024) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.3125
Homme, J. L., Kranz, L. A., House, M., & Greenmyer, J. R. (2025) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2025.04.012
PROSPECTS OF HOLTER MONITORING IN THE DIAGNOSIS OF HEART AND VASCULAR DISEASES (literature review)
Aleynikova, T. V., & Мистюкевич, И. И. (2014) · Health and Ecology Issues · doi:10.51523/2708-6011.2014-11-1-2
A Study on ECG Signal Reconstruction based on Deep Learning Model for Heart Disease Detection
Kim, M.-G., & Jung, J. H. (2025) · The Journal of Korean Institute of Information Technology · doi:10.14801/jkiit.2025.23.10.143
Sharma, P., Sharma, P., Sharma, K. H., & Sojitra, P. N. (2025) · Cureus Journal of Computer Science. · doi:10.7759/s44389-025-10001-6 · Cited by 1
The Diagnosis of Cardiac Arrhythmias
Richardson, A., & ZIMETBAUM, P. J. (2002) · Contemporary cardiology · doi:10.1007/978-1-59259-090-2_2
Métodos não-invasivos de análise funcional cardíaca
Rocha, M. O. D. C., Ribeiro, A. L. P., Torres, R. M., & TOSTES, V. T. V. (1997) · Editora FIOCRUZ eBooks · doi:10.7476/9788575412435.0015
Himmelreich, J. C. L., Lucassen, W. A. M., & Harskamp, R. E. (2026) · doi:10.1007/978-90-368-3158-1_28
Med2ECG: Medical-Guided BCG-To-ECG Reconstruction for Diverse Populations
Chen, L., Huang, Y., Li, C., Chen, J., Zhong, S., Qiu, M., Guo, C., Wang, Y., Zhang, Q., & Wu, K. (2026) · doi:10.1145/3774906.3800463
Mamba-BiSAMNet: An ECG denoising network for multi-type noise removal
Xing, Z., Cheng, Y., & Hua, Z. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111463
Palpitations of Unknown Origin: How Frequent are Supraventricular Arrhythmias?
Giada, F., & Raviele, A. (2004) · Springer eBooks · doi:10.1007/978-88-470-2137-2_33
Metadata
- Authors
- DiMarco, J. P., & Philbrick, J. T.
- Affiliations
- University of Virginia Medical Center (US)
- Corresponding author
- DiMarco, John P.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1990-07-01
- Volume
- 113
- Issue
- 1
- Pages
- 53-68
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1979276457
- Cited by
- 177
- References
- 134
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 8 · 2023: 4 · 2022: 9 · 2021: 9 · 2020: 2 · 2019: 4 · 2018: 4 · 2017: 2 · 2016: 2 · 2014: 6 · 2013: 8 · 2012: 1
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- Holter monitoring, arrhythmia monitoring, myocardial ischemia, ST-segment changes, antiarrhythmic drugs, ventricular ectopy, serial ECG monitoring, anti-ischemic therapy
- MeSH terms
- Arrhythmias, Cardiac, Coronary Disease, Humans, Predictive Value of Tests, Prognosis, Reproducibility of Results, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review